1 / 79

ENVIT: Software Tools for Environmental Field Study

ENVIT: Software Tools for Environmental Field Study. Hydrologic Modeling Hardware & Field Equipment User Interface HydroLab Probe GIS / GPS. ENVIT: Hydrologic Modeling Division. Anna Leos-Urbel Kevin Richards Eric Lau. The Hunter River Basin. Water Quality Background.

silas
Télécharger la présentation

ENVIT: Software Tools for Environmental Field Study

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ENVIT:Software Tools for Environmental Field Study Hydrologic Modeling Hardware & Field Equipment User Interface HydroLab Probe GIS / GPS

  2. ENVIT:Hydrologic Modeling Division Anna Leos-Urbel Kevin Richards Eric Lau

  3. The Hunter River Basin

  4. Water Quality Background • November 1991 – 1000km toxic algal bloom along Barwon and Darling rivers in New South Wales • Summers 1991-1993 – non-toxic algal blooms in Grahamstown Reservoir • Australia spends $142-168 million per year on monitoring quality

  5. Main Quality Factors • Turbidity • Salinity • Nutrients (N, P) • Blue-green algae (cyanobacteria) • Fecal Coliform

  6. Strategies • Extensive monitoring • HITS • Hunter Water Corporation • Hunter Salinity Trading Scheme • Contingency plans • Prevention measures

  7. Sampling Locations • Tillegra Dam Site • Chichester Dam • Glen Williams Site • Boags Hill/Seaham Weir Site • Nerrigundah

  8. Sampling Agenda • Turbidity, Conductivity, Chlorophyll-a • Nitrate, nitrite, ammonia • Organo-phosphate • Total Iron • Silica • Cyanobacteria • Fecal Coliform

  9. Assessment Against Guidelines

  10. Expected Range of Results (January)

  11. Average Results (year)

  12. ENVIT:Hardware Division Jamie Brady Trisha McAndrew Laura Rubiano Gomez Advisor: Richard Camilli

  13. Project Description • Protective Cover (GPS/iPAQ/Expansion Pack/Cables) • External battery for HydroLab/iPAQ • Power meter • Flow meter modification • Calibration materials and guidelines for field equipment • Parameters for manual probe GUI

  14. ENVIT Power System

  15. Water-proof Casing • Aquapac • Modified to accommodate cables Power Jack Hydrolab

  16. External Battery Pack • Hydrolab powerpack • DC-DC converter • Connects the system • Power meter

  17. External Battery Pack • Connects iPAQ and HydroLab to power source

  18. Power Meter • Circuit Design • Determine: • Voltages when 95%, 60%, 20% and 10% of power remaining • Use above voltages to find: • Resistor values for R1-R6 • Potentiometer value • Zener diode value • Put circuit board together

  19. R2 R1 1000 12v green R3 P1 1000 amber R4 1000 amber R5 +12v 1000 red Z1 R6 Values for the six resistors (R1-R6)and potentiometer (P1), are based on the voltage reference value chosen for the zener diode (Z1) and assuming an input current range for the operational amplifiers of between 1A and 100A. The op-amp used is a quad-input National Semiconductor LM324. (http://www.national.com/ds/LM/LM124.pdf.) Power Pack Monitor R1 = 169 K R2 = 499 K R3 = 11 K R4 = 11.3 K R5 = 9.09 K R6 = 249 K

  20. ENVIT Power Pack Monitor

  21. Flowmeter

  22. Biology Kit • Parameters: • E. coli • Total Coliform

  23. Spectrophotometer • Figure out how it works! • Determine elements we can test for • Order necessary supplies for tests and calibration

  24. Parameters: Ammonia Nitrate (LR, MR) Nitrite Phosphate Silica Spectrophotometer

  25. Design a waterproof casing for battery Better arrangement of wires coming out from battery pack Larger Aquapac or other protective cover to facilitate removal of iPAQ Future Improvements

  26. ENVIT:User Interface Division Amy Watson Nancy Choi Kim Schwing

  27. ENVITNote • Environmental software application for hand-held, portable computers to be used directly for gathering and storing data (an electronic journal). • Record environmental and geolocational data automatically in the field. • Applications for hydrology sampling, water quality sampling, field mapping (GIS) and positioning (GPS).

  28. The User • Who is the user? • What are the user’s goals?

  29. Graphical User Interface (GUI) “A program interface that takes advantage of the computer’s graphics capabilities to make the program easier to use. Well-designed graphical user interfaces can free the user from learning complex command languages.” (www.pcwebopedia.com)

  30. GUI Group Deliverables • User and Project setup • Control screens • Interaction with database • Computation applications

  31. User Centered Design • “Simple is better” • Programs that flow logically • Understandable format • Standardize functionality

  32. Visual Basic • Microsoft developed programming language and environment. • Based on the BASIC language • Provides a graphical programming environment and a paint metaphor for developing user interfaces. • Do not need to worry about syntax details • Can add code by dragging and dropping controls and then defining their appearance and behavior.

  33. Microsoft eMbedded Visual Tools 3.0 • The Microsoft® eMbedded Visual Tools 3.0 delivers a complete desktop development environment for creating applications and system components for Windows® Powered devices, including the Pocket PC and Handheld PC. • The eMbedded Visual Tools include eMbedded Visual Basic® and eMbedded Visual C++®, including SDKs for the Pocket PC, Palm-size PC, and Handheld PC.

  34. Components of the GUI • Welcome • Login • Instrument Identification • Control Form – tab strip format • Menu Bar Options

  35. ENVITNote Demonstration

  36. ENVIT:HydroLab Probe Division Arthur Fitzmaurice Chrissy Dobson Lisa Walters

  37. Tasks • Provide “black box” of device • Enable serial communication between iPAQ and HydroLab • Enable user to calibrate HydroLab sensors and collect water quality data • Provide user with error and range check

  38. Progression of the Hydrolab GUI • Read HydroLab manual • Developed preliminary list of parameters and units • Researched calibration requirements • Created GUI for calibrating parameters, taking measurements, and displaying data • Developed list of ranges for each parameter and possible errors

  39. Chlorophyll (g/L) Conductivity(mmHg, psia) Salinity (ppt) Specific Conductance (ms/cm) Resistivity (k-cm) Total Dissolved Solids (g/L) Depth(m, ft, psi) Dissolved Oxygen(mg/L, %Sat) pH Temperature(K, F, C) Turbidity(NTU, V) Parameters and Units

  40. When to Calibrate the Sensors • Factory calibrated • Site –specific • Frequency of deployments

  41. How to Calibrate a Sensor Example: Dissolved Oxygen • Select parameter: Dissolved Oxygen • Temperature does not require calibration • Prepare sensor for calibration • Instructions for calibration preparation in user manual • Choose %Sat • Enter barometric pressure (mmHg)

  42. How to Take a Measurement Example: Dissolved Oxygen • Select parameter: Dissolved Oxygen • Select units: % saturation, mg/L • Multiple samples? • Enter sampling time and units (i.e. seconds, minutes, hours, days) • Enter time interval and units

  43. Potential Errors • Hydrolab off or improperly connected • Serial port in use by other application • Battery not attached or not enough power • Parameter called by user not available on specific Hydrolab • Parameter called by user not calibrated • Calibration expired or not available for parameter • Hydrolab data not within valid range • Time interval greater than total sampling time

  44. HydroLab GUI