1 / 21

Spin thermopower in the overscreened Kondo model

NanoCTM final network meeting and workshop Poznań, 23-27 September 2013. Spin thermopower in the overscreened Kondo model. Tomaž Rejec, Rok Žitko, Jernej Mravlje and Anton Ramšak Department of Physics, University of Ljubljana Jožef Stefan Institute, Ljubljana. Outline.

singhk
Télécharger la présentation

Spin thermopower in the overscreened Kondo model

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NanoCTM final network meeting and workshop Poznań, 23-27 September 2013 Spin thermopower in the overscreened Kondo model Tomaž Rejec, Rok Žitko, Jernej Mravlje and Anton Ramšak Department of Physics, University of Ljubljana Jožef Stefan Institute, Ljubljana

  2. Outline • Spin-Seebeck coefficient • Kondo models (fully screened, underscreened, overscreened) • NRG results

  3. Spin-Seebeck coefficient TL=TR L V=0 R

  4. Spin-Seebeck coefficient TL=TR L V≠0 R

  5. Spin-Seebeck coefficient TL=TR L V≠0 R

  6. Spin-Seebeck coefficient TL>TR L V=0 R

  7. Spin-Seebeck coefficient TL>TR L V=0 R

  8. Spin-Seebeck coefficient TL>TR L ed≠0 V=0 R

  9. Spin-Seebeck coefficient TL>TR L ed≠0 V≠0 R Seebeck coefficient

  10. Spin-Seebeck coefficient TL>TR L B≠0 V=0 R

  11. Spin-Seebeck coefficient TL>TR L B≠0 V=0 R Spin current!

  12. Spin-Seebeck coefficient TL>TR L B≠0 Vs≠0 R Spin-Seebeck coefficient Spin voltage:

  13. Spin-Seebeck coefficient For small DT, Vs: Non-interacting QD: B>G B=G B<G

  14. Kondo models NFL: J1=J2 : overscreened Kondo effect

  15. Kondo models

  16. Kondo models S=1/2; i=1 : fully screened Kondo model S=1/2; i=1,2 : overscreened Kondo model S=1; i=1 : underscreened Kondo model

  17. Results – fully screened Kondo model B=TK B>G B=G B<G

  18. Results – overscreened Kondo model NFL FL

  19. Results – underscreened Kondo model

  20. Summary • Measuring the spin thermopower at low magentic fields would provide a sensitive test for distinguishing between fully screened, underscreened and overscreened Kondo behaviour • Possible applications: generation of spin current for spintronics applications, sensitive measurement of low magnetic fields

More Related