EMD545b Lecture #7 Controls in Biosafety III

EMD545b Lecture #7 Controls in Biosafety III. Decontamination and Emergency Response. Decontamination. Encompasses: antisepsis, disinfection, decontamination, and sterilization Antisepsis chemical applied to living tissue that will control or arrest the growth of a microorganism

soderlund
Télécharger la présentation

EMD545b Lecture #7 Controls in Biosafety III

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EMD545b Lecture #7Controls in Biosafety III Decontamination and Emergency Response

  2. Decontamination • Encompasses: • antisepsis, disinfection, decontamination, and sterilization • Antisepsis • chemical applied to living tissue that will control or arrest the growth of a microorganism • Decontamination • disinfection or sterilization of contaminated materials

  3. Decontamination • Disinfection • To free from infection, reduction of contaminant load to a safe level, does not imply total destruction of all microorganisms. Will not always destroy spores. • Sterilization • The destruction of all forms of microbial life. Difficult to achieve (usually referred to a very low chance that a microbe survived).

  4. Disinfection in Healthcare • High-Level Disinfection • sporicidal/tuberculocidal (but used for shorter times than required for sterility). Equipment that will have invasive contact with patient. • Intermediate • tuberculocidal (equipment that will contact mucous membranes of patient) • Low-level (kills vegetative bacteria) • for non-critical equipment (no invasive contact)

  5. Sterilants - Physical Methods • Steam Autoclave • steam under pressure --> moist heat • 121 C/250 F @ 15 psi for 30 - 60 minutes • Dry Heat • 160 - 170 C/320 - 356 F for 2 - 4 hours • Incineration • 2 stage burn, 1400 & 1800 F

  6. Sterilants - Gases • Formaldehyde gas • heat formalin to vaporize it (1 ml/ft^3) • heat paraformaldehyde (0.3 g/ft^3) • 2 hour exposure time required (8 hour or overnight contact period recommended) • can neutralize HCHO (toxic, suspect carcinogen) with ammonium bicarbonate • room temperature > 70 F, %RH - > 70%

  7. Sterilants - Gases • Ethylene Oxide • 400 - 800 mg/L • 35 - 60 C temperature, 30 - 60% RH • contact time up to 4 hours • Hydrogen Peroxide • vaporize from 30% H2O2

  8. Liquid Disinfectants • Surface treatment or to treat liquid waste • Inactivate by • coagulation, denaturation, lysis, enzyme inactivation • Factors to consider: • temperature, humidity, pH • contact time, concentration • penetrability • presence of organic material

  9. Liquid Disinfectants • Alcohol • Ethanol, Isopropanol ( 70 - 85%) • requires presence of water for protein denaturation • bactericidal (vegetative bacteria) • virucidal (enveloped viruses) • Not sporicidal • Not as effective against non-enveloped viruses) • flammable • low BP, higher evaporation rate, difficult to get 10 minute contact time

  10. Liquid Disinfectants • Glutaraldehyde • stable in and stored in acid pH range • activated by adding sodium bicarbonate to elevate pH to > 7.5 (14 day shelf-life) • contact time (10 - 180 minutes) • sporicidal at longer contact times • sterility requires 6 - 10 hours • non-corrosive • effective in presence of organic material

  11. Liquid Disinfectants • Formaldehyde (4 - 8 %) • active in alkaline pH range, non-corrosive • effective in presence of organic material • diminished activity in colder temperatures • 10 - 30 minute contact time required • fixative (penetration rate of 8mm/24 hours in tissue specimens) • wide spectrum disinfectant • suspect carcinogen, toxic at low levels

  12. Liquid Disinfectants • Phenol (0.2 - 3%) • Not sporicidal, not effective against non-enveloped viruses • Tuberculocidal, fungicidal, bactericidal • not affected by presence of organic material • hard water can affect effectiveness • Toxic, can be absorbed through skin (large spills to skin can be fatal)

  13. Liquid Disinfectants • Quaternary Ammonium Compounds (0.1 - 2%) • cationic detergents, very good cleaning agents • inactivated by organic material • bactericidal, algicidal, fungicidal, will destroy enveloped viruses • not tuberculocidal or sporicidal • low-level disinfectant • good for general surfaces and floors • very toxic to eyes (a few drops can lead to blindness)

  14. Liquid Disinfectants • Halogens - chlorine (0.01 - 5%) • wide spectrum of activity • acts rapidly at low concentrations (10 - 30 min.) • inactivated by organic material (use more) • will lose chlorine upon exposure to light/air • more cidal at low pH, good at lower temps. • very corrosive

  15. Liquid Disinfectants • Halogens - Iodine (0.47%, 75 - 1600 PPM) • inactivated by protein • 1600 PPM inactivates wide spectrum of agents • effective over wide pH range • tuberculocidal, sporicidal • corrosive, will stain, toxic, allergenic • Dilution issue - must follow recommended dilutions for iodophors (or iodophor may not be as effective)

  16. Liquid Disinfectants • Hydrogen Peroxide (3% - 25%) • stable, non-toxic, fast acting • 10 - 25% solutions are sporicidal • inactivated by organisms that produce catalase

  17. Rank Order of Resistance to Disinfection • Prions • Protozoan cysts • Bacterial spores • Non-enveloped (hydrophilic) viruses • Mycobacteria • Fungal spores, fungi • Vegetative bacteria • Enveloped viruses (lipophillic)

  18. Verification of Decontamination • Autoclave tape • time/temperature/date records on chart • Chemical indicators (diack melt pellets) • fuse if temperature reached for at least 1 second • Biological Spore indicators • Bacillus stearothermophillus • Bacillus subtilis var. niger • Manifest for biomedical waste (incineration)

  19. Emergency Response • Percutaneous exposure • immediately wash well with soap & water • wash should last 15 minutes • dilution of wound most important, soap & water most readily available cleanser • Notify supervisor (if available) • don’t let this delay medical attention • inform that you are heading to Health Services • ask them to initiate incident report (mail to Health Services later) - start review of incident

  20. Emergency Response • Percutaneous exposure • seek medical assistance within 1-2 hours • verify proper cleansing • baseline serum taken, tested initiated if appropriate • post-exposure prophylaxis provided if necessary • counseling offered • Before initiating work: • ensure working sink, soap, paper towels present • suitable disinfectant if used

  21. Emergency Response • Facial mucous membrane contact • (eyes, nose, mouth) • wash well in eye wash for 15 minutes • eye wash station checked weekly • flow will hit eyes/face (strength, direction) • clear, clean water • unit can be activated for hands-free operation in 1.5 seconds • hold eyelids open with hands • know location of eyewash and how to use before starting work • vision may be impaired in exposure situation

  22. Emergency Response • Aerosol exposure • BL2 • leave lab upon release • Wash wounds, flush face/eyes if exposed, wash hands • post sign, keep area vacated for 20 - 30 minutes to allow aerosols to settle • decontaminate personnel clothing, skin • notify lab supervisor, biosafety, and Health Services if necessary

  23. Emergency Response • Aerosol exposure • High risk BL2, BL2+, BL3 • hold breath, drop gloves on floor, and immediately proceed to the anteroom • remove all lab clothing and any personal clothing that may have been contaminated • wash all exposed skin surfaces, hands • post sign to alert of spill

  24. Emergency Response • Aerosol exposure • verify airflow direction into lab • call safety, principal investigator • no entry until joint risk assessment with safety • all exposed report to Health Service

  25. Exposure Incident Follow-up • documented written report • name, lab, department • date, time, location • description of incident • risk assessment for health services • material involved (biohazard, fixed, etc.) • wounds, visible cuts on person • route of exposure, estimated dose (concentration/volume) • depth of wound

  26. Exposure Incident Follow-up • Experience of person involved • safety training records • prior accidents/exposures • Object/items involved • sharps (type, brand, reusable/disposable) • location of needlebox • animals • During preparation/use/disposal/cleaning?

  27. Exposure Incident Follow-up • Appropriate onsite response after incident? • wash, report, visit to Health Services • Personal protective equipment worn at time • Engineering controls in use? • What were the safety practices at time? • How is the area decontaminated/cleaned? • What is their plan to prevent recurrence? • What can you add after the review? • Write up new SOP and check periodically

  28. Accidents & Illnesses • prompt reporting • immediate medical assistance • serum samples, stool specimens, nasal and skin washings • investigate serious, unusual or extended illnesses

  29. Report of seroconversion • examine worker • investigate procedures • revise procedures to eliminate exposure

  30. Biohazard Spills • BL1 • can clean immediately w/ basic PPE • Spill in a biosafety cabinet • already contained • can initiate clean-up immediately at all levels • for spills that go into grilles, flood drain pans with disinfectant (ensure that drain is closed) and call safety for evaluation - more extensive decon may be needed

  31. Biohazard Spills • BL2 spill (outside containment equipment) • evacuate lab for 20 - 30 minutes • treat exposed, remove lab clothing, wash • post-sign • call safety if exposure risk (airborne) high • defined area on floor, bench? - lab • widespread aerosol throughout room (centrifuge incident) - safety assistance needed

  32. Biohazard Spills • BL3 (spill outside containment equipment) • evacuate lab • remove PPE in anteroom (contaminated clothing) • wash/decon all exposed skin surfaces, face & hands • post sign • verify airflow direction • call safety & PI, notify Health Services • lab remains closed until cleared by Safety

  33. Spill Decontamination • Spill kit (assembled in advance, kept in BL1, BL2 labs, outside of BL3 labs) • concentrated disinfectant (appropriate for agent in use) • paper towels, biohazard bags • squirt bottle • sharps container, forceps/tongs • lab coat/gown, gloves, utility gloves • full face protection, booties • respiratory protection as required

  34. Spill Decontamination • COVER • cover spill area with paper towels • DISINFECT • slowly pour disinfectant around perimeter and into the center of spill area. 10-15 minute contact time. • Clean/disinfect surrounding areas • CLEAN • absorb spill and paper towels and place in biohazard bag. Sharps placed in sharps container. • DISINFECT • spray spill area with disinfectant, allow to air dry

  35. Mixed Biohazard Spill • Chemical/biohazard spill • will chemical inactivate the biohazard? • is chemical a listed hazardous or toxic waste? • chemical safety risk assessment (PEL, TLV, exposure routes, chemical PPE) • chemical neutralizers or absorbents used • inactivate biohazard component of waste and discard as hazardous chemical waste • check for incompatibilities with proposed disinfectant

  36. Mixed Biohazard Spill • Radioactive/biohazard spill • again, more regulated waste takes precedence • inactivate the biohazard component and discard as radioactive waste • avoid bleach with 125-I (radioiodine gas may be released) • booties required for radioactive spill • Geiger-mueller, Scintillation probes (NaI), Liquid Scintillation Counters to determine scope of radioactive contamination

  37. BL3 Emergency Response • Airflow alarm in BL3 lab - work in progress • all work under containment • stop work @ time of alarm, remove outer gloves, verify airflow reversal • if verified, cap all cultures and return to incubator or freezer • decontaminate work surfaces in biosafety cabinet, leave waste inside cabinet, leave cabinet on • remove PPE, leave lab, post “lab down” sign, and notify safety, PI, and maintenance

  38. BL3 Spill @ time of Airflow Alarm • Worst-case breach • Verify interlock of supply with exhaust • did supply also shut down? • is air movement neutral and not out of lab? • duct tape around entire door to seal in lab • shut exhaust/supply dampers to/from BL3 lab • if breach, may have to evacuate adjacent rooms, floor, building??? • Rapid notification to safety, PI, maintenance • Why redundancy/emergency power so important in BL3 labs!

  39. Non-Ambulatory Researcher in BL3 Lab • Prompt notification • 2 person team approach • good visual access inside the lab • video surveillance • method of communication outside the lab • Consider person and all clothing contaminated • EMT’s w/ PPE enter with support or safety personnel • EMT’s provide medical assistance • Safety or support cuts off/removes/decontaminates PPE and regular clothing • 2 EMT’s outside lab awaiting transfer of patient

  40. Non-Ambulatory Researcher in BL3 Lab • Decontaminate EMT’s equipment • may have to buy new supplies (BSL3 stigma) • Evaluate contamination of laboratory • gas decontamination may be required • Level of coordination must be practiced • schedule drills periodically • Always hold a post-incident review (lessons learned) session - will benefit all involved

  41. Maintain a spill kit for cleaning biological spills. Keep the spill kit outside the BSL-3 Lab (to prevent contamination of supplies)

  42. Biohazard Spills • BSL-3 (spill outside containment equipment) • evacuate lab • remove PPE in anteroom (contaminated clothing) • wash/decon all exposed skin surfaces, face & hands • post sign • verify airflow direction • call safety & PI, notify Health Services • lab remains closed until cleared by Safety

  43. Spill Decontamination – BSL-3 • Confine spread of contamination to smallest possible zone • HEPA filtered space? • Exhaust location? Notify Plant Maintenance • Determine extent of contamination within zone • Exposed personnel to Employee Health after decon • Environmental stability of spilled agent? • Is time on your side? Wait it out • Unique requirements for agent? (immunization, PPE – any responders at high risk? • Default to HEPA-filtered PAPR for emergency entry

  44. Spill Decontamination – BSL-3 • What is the 99.9% particle clearance time for the BSL-3 Lab in minutes? • Is manual facility chemical decontamination sufficient? Which chemicals are effective? • Determine need for Space Decontamination • How sealed/sealable is the space? • Can you achieve parameters required for space decon? • Select remediation plan with incident commander (EHS, FD, FBI?) – Level A/B/C/D Response? • Are clearance swab samples/air samples required to document destruction?

  45. Spill Decontamination (Aerosol release throughout laboratory) • Large area decontamination • Gas decontamination • Formaldehyde, chlorine dioxide, vaporized H202? • Outside vendor? EH&S? • Sealed laboratory? • Liquid Chemical Decontamination • Foggers, sprayers? • Contact time? Biological indicators? • Process verified/lab cleared prior to reuse

  46. Spill Decontamination – BSL-3 • Release of a Select Agent from BSL-3 lab? • Immediate agency notifications by RO/ARO • Public Health Risk from release of agent? • Public Affairs Office (EHS Director, CEO) • City/Town Dept. of Public Health • State Dept. of Public Health • CDC? • Lessons learned meeting? • Was response protocol effective? • Identify areas of improvement?

  47. Spill Decontamination • COVER • cover spill area with paper towels • DISINFECT • slowly pour disinfectant around perimeter and into the center of spill area. 10-15 minute contact time. • Clean/disinfect surrounding areas • CLEAN • absorb spill and paper towels and place in biohazard bag. Sharps placed in sharps container. • DISINFECT • spray spill area with disinfectant, allow to air dry

More Related