How does adding and removing liquid from socket bladders affect residual-limb fluid volume?

How does adding and removing liquid from socket bladders affect residual-limb fluid volume?. Joan E. Sanders, PhD; John C. Cagle, BSE; Daniel S. Harrison; Timothy R. Myers, MME; Kathryn J. Allyn, CPO. Aim

suchin
Télécharger la présentation

How does adding and removing liquid from socket bladders affect residual-limb fluid volume?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. How does adding and removing liquid from socket bladders affect residual-limb fluid volume? Joan E. Sanders, PhD; John C. Cagle, BSE; Daniel S. Harrison; Timothy R. Myers, MME; Kathryn J. Allyn, CPO

  2. Aim • Determine how adding and removing liquid from socket bladders affects residual-limb fluid volume. • Relevance • Adding and removing liquid from socket bladders allows people with limb loss to accommodate residual-limb volume change.

  3. Method • 19 people with transtibial amputation were fit with fluid bladders on inside socket surface. • Subjects sat, stood, and walked for 90 s with bladder liquid: • Added. • Removed. • Bladder liquid amount increased each cycle. • Bioimpedance analysis measured residual-limb fluid volume.

  4. Results • Preferred bladder liquid volume: • 16.8  8.4 mL, corresponding with 1.7%  0.8% of average socket volume between bioimpedance voltage-sensing electrodes. • Fluid volume driven out of residual limb when bladder liquid was added was typically not recovered on later bladder liquid removal. • 15 subjects had gradual residual-limb fluid volume loss over test session.

  5. Conclusion • Care should be taken when implementing adjustable socket technologies in people with limb loss. • Reducing socket volume may accentuate residual-limb fluid volume loss.