1 / 34

Approach to Utility MATS August 22, 2012

Approach to Utility MATS August 22, 2012. Joel Millard Environmental Regulatory Specialist KVB-Enertec Products Babcock & Wilcox Power Generation Group, Inc. ARIPPA Annual Tech Convention Harrisburg, PA. Presentation Agenda. Utility MATS Overview. PM Compliance Options and Cost Analysis.

Télécharger la présentation

Approach to Utility MATS August 22, 2012

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Approach to Utility MATS August 22, 2012 Joel Millard Environmental Regulatory Specialist KVB-Enertec Products Babcock & Wilcox Power Generation Group, Inc. ARIPPA Annual Tech Convention Harrisburg, PA

  2. Presentation Agenda Utility MATS Overview PM Compliance Options and Cost Analysis HCL Compliance Options and Cost Analysis Hg Compliance Options Summary

  3. Mercury and Air Toxics Standards (MATS) • 40 CFR Part 63, Subpart UUUUU – National Emission Standards for Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility Steam Generating Units • Also known as the Utility MACT • Final rule published in the Federal Register on February 16, 2012 • Effective 60 days from publishing in FR (April 16, 2012) • Affected sources have 3 years from this date to become compliant* • Notifications of applicability were due August 14, 2012 • Temporary stay of limits for new units in place. Stay in effect until November 2, 2012 *note: it appears that the EPA will grant a one year extension for sources that are showing an effort to achieve compliance

  4. Timeline for ComplianceMercury and Air Toxics Standard (MATS) • Covers Filterable Particulate Matter as a marker for heavy metals,HCl or SO2 as a marker for acid gasses, and Mercury State Extensions Available Nominal Compliance Deadline Negotiated Enforcement Orders Possible 2012 2017 2012 2015 2013 2014 2016 2017 Rule publishedin Federal Register Compliance Begins

  5. UMATS – PM Limits * Includes Hg PM

  6. UMATS – HCl/SO2 Limits * SO2 Limit only for units with FGD

  7. UMATS – Hg Limits

  8. Presentation Agenda Utility MATS Overview PM Compliance Options and Cost Analysis HCL Compliance Options and Cost Analysis Hg Compliance Options Summary

  9. What is PM ? • Particles exist in both solid and liquid • Filterable and Condensable • Particle sizes and shapes vary • PM characteristics will vary with fuel and controls technologies • Temperature and Pressure of sample also affect PM Salts Organic Hydrocarbons Carbon Metals

  10. Why Measure PM? • Opacity correlates poorly to PM emissions • All States require opacity monitoring • PM CEMs can measure PM mass and low PM concentrations,which opacity monitors cannot • Consent Decrees • Technology now available to measure PM emissions and new EPA test standards available

  11. PM Compliance Options • Measure using PM CEMS • Measure using a Continuous Parametric Monitoring System (CPMS) and perform annual compliance testing • Quarterly testing for PM/Non-Hg Hap Metals • PM filterable – Method 5 test - $14K • Total HAP Metals – Method 29 train - $15K/quarter • Individual HAP Metals (10) - More $$ than Method 29 test NOTE: Annual Compliance test not required for Option 3

  12. PM CEMS • Permissible Monitor Types for MATS Compliance • Light Scatter • Scintillation • Beta Attenuation • Mass Accumulation Beta Gauge Extractive Back Scatter Extractive Back Scatter In-Situ

  13. PM CEMS Certification • PM CEMS must initially be certified in accordance with 40 CFR Part 60, Appendix B, Performance Specification 11 (PS-11) • Test to generate a correlation curve between the particulate concentration and the unit load • Requires at least 15 Paired samples 3 loads, 5 runs per loading level • Tests are time consuming and expensive (35k-50k), and can cause problems with the state regulatory agency

  14. Ongoing QA/QC procedures • Outlined in 40 CFR 60, Appendix F, Procedure 2 • Absolute Correlation Audit (ACA) – Challenge the analyzer with three filters (quarterly) • Relative Response Audit (RRA) – 3 particulate tests, normal load (annual) • Response Correlation Audit (RCA) - Basically 12 run PS -11 (every 3 years)

  15. PM CEMS vs. CPMS • UMATS allows for EITHER PM CEMS OR CPMS • Both technologies must use Light Scatter, Scintillation, Beta Attenuation, or Mass Accumulation What is the Difference ? • CPMS – Not a certified PM CEMS – Similar technology • Parametric limit is determined from annual testing • PM CEMS – Initial capital cost & testing is more $$ • PM CEMS – Exempt from Opacity monitoring (Pending state approval)

  16. PM (Dry Stack) Monitoring Options - Costs

  17. PM (Wet Stack) Monitoring Options - Costs

  18. Presentation Agenda Utility MATS Overview PM Compliance Options and Cost Analysis HCL Compliance Options and Cost Analysis Hg Compliance Options Summary

  19. Compliance Options • Continuously monitor HCL concentrations • Continuously monitor SO2 concentrations • Coal fired sources already have SO2 analyzers installed • Requires that the source has a wet or dry FGD • Once a plant opts in to using SO2 as a surrogate, the 0.20 lb/MMBtu limit becomes federally enforceable • some clients choosing not to use this option, due to the reduction of fuel flexibility

  20. HCL • Limit is 0.002 lbs/mmBTU (~1.9 ppm) – Coal fired units • Initial and Annual testing – Method 26 or 26A • Initial CEMS requirements being developed - PS-18 • Annual compliance tests are $14K – 3 – 1 hour runs • HCl CEMS types: • FTIR – Hot, wet extractive • TDL – In-situ, cross stack/duct • Gas Filter Correlation Infra-red (GFC) – Hot, wet extractive • New probes/ports required for most applications • HCl CEMS have been in use for many years on waste incinerator applications

  21. HCl Monitoring - Cost Comparison Notes: Certification costs are equivalent: ~$14K FTIR cost assumes 200 ft. Sample Line Cost of power is excluded TDL – No sample lines required, only measures HCl TDL – Lower cost option for “ADD-ON” measurement FTIR – Capable of measuring multiple components (more flexible)

  22. HCl Monitoring Options - Costs

  23. PM&HCl (Dry Stack) Monitoring Options - Costs

  24. Presentation Agenda Utility MATS Overview PM Compliance Options and Cost Analysis HCL Compliance Options and Cost Analysis Hg Compliance Options Summary

  25. Hg Compliance Options • Continuous Monitors must be installed • Two technologies currently available • Hg analyzer • Continuous Sorbent Trap Monitoring System Sorbent Trap System

  26. Hg Monitoring – Technology Comparison • Both Hg CEMS and Sorbent trap are certified using Method 30B • Hg CEMS have continuous data – Sorbent trap gives weekly updates (5-7 days, no longer than 14 days) • Sorbent trap is lower capital cost • O&M costs for each similar – Hg CEMS may be higher maintenance for some applications • Control Device for Hg is a factor in deciding continuous vs. sorbent trap

  27. Hg Monitoring - Cost Comparison Notes: Certification costs are equivalent Annual certification test costs are similar Sample Line costs are excluded Cost of air compressor for Hg CEMS should also be considered Sorbent trap need easy access to probe location

  28. Hg CEMS • Typical design is a dilution extractive system • Analyzer measures elemental Hg • Measurement levels are extremely low • Ionic Hg is converted to elemental Hg • Hg CEMS are more complex than conventional CEMS • Capital, installation, and O&M costs are higher • Alternative to Hg CEMS is Sorbent Trap System (non-continuous)

  29. Hg Sorbent traps • Can be used instead of CEMS measurement & also for ref. method stack tester • Uses dual train carbon traps mounted in tip of probe in stack • Hg is collected on carbon traps and sent to lab for Hg analysis (in most cases every 5-7 days) • Must measure sample flow, stack flow, and stack conditions • Issues: Loose 5-7 days of data if traps fail QA tests • Hg reading are batch sample – I.e. Non-Continuous

  30. Presentation Agenda Utility MATS Overview PM Compliance Options and Cost Analysis HCL Compliance Options and Cost Analysis Hg Compliance Options Summary

  31. Summary • Particulate Matter • PM CEMS • CPMS and Annual Testing • Quarterly testing for PM or Non-Hg HAP Metals • Hydrogen Chloride • FTIR - More accurate but more expensive • TDL- Lower cost and easier to integrate, may have some issues with data accuracy • Mercury • Mercury CEMS - Costlier method, however real time data is available • Sorbent Trap System – Lower cost method, however data is not available and it is more labor intensive for the plant personnel

  32. UMATS - PM & HCl Cost Comparisons • If PM only is considered – PM CPMS may be the lower cost option • If SO2 Limit/SO2 CEMS is not an option and HCl must be measured • Combining Method 5 and Method 26A quarterly testing may be the lower cost option for HCl & PM • If HCl only is considered – Then HCl CEMS may be the lower cost option • Assumes a 3-4 year payback – Capital + O&M

  33. Basis of Cost Analysis • Lowest cost analyzer capital cost • TDL technology utilized for HCl-CEMS • Installation costs included, assuming steel stack and • no platform work • Includes certification, quarterly testing, and recertification • every 3 years for PM-CEMS • Includes initial certification and annual testing for CPMS • Potential elimination of opacity O&M costs with PM-CEMS • not included • Estimates based on today’s dollar non-escalated • Based on single stack

  34. Thank you!

More Related