Cold Test SLED Signals from Combiner input to 3dB Divider output

This document outlines the cold test results for the SLED signals from the combiner input to the 3dB divider output. The measured loss was approximately -2.42 dB, with a scattering parameter |S21| of 0.757. The first bin recorded values of ~0.216, 0.613, and 0.757*2, resulting in a total of ~0.9335. The transmission efficiency achieved was around 87.15%. The SLED gain measured at ~2.80, which is slightly under-tuned; the target is ~3.1. The overall gain was approximately 2.44, with a goal of reaching 2.7.

Télécharger la présentation

Cold Test SLED Signals from Combiner input to 3dB Divider output

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.