Status and Future of RPC Front-End Electronics: Longevity Issues and Upgrades Post-LS1

tavi avatar
5 diapositives · 192 Views · Jul 18, 2014

At the RPC Upgrade meeting (n.5), Flavio Loddo from INFN-Bari presented the current status of front-end (FE) electronics in RPC systems at LS1. FE boards have shown few failures, with 97.4% of active channels functioning, but distribution boards revealed fragilities. With replacement of old boards deemed unrealistic, attention turns to future longevity, particularly concerning radiation tolerance. A new campaign for irradiation tests is proposed to assess the FE electronics for Phase 2 operations. Discussions focus on strategies for mitigating potential failures after LS1 and beyond.

Status and Future of RPC Front-End Electronics: Longevity Issues and Upgrades Post-LS1 - slide 1
01 / 5Status and Future of RPC Front-End Electronics: Longevity Issues and Upgrades Post-LS1
1 / 17

Télécharger la présentation

Status and Future of RPC Front-End Electronics: Longevity Issues and Upgrades Post-LS1
Une image / un lien ci-dessous est fourni (tel quel) pour télécharger la présentation

Politique de téléchargement : le contenu du site vous est fourni TEL QUEL pour votre information et votre usage personnel ; il ne peut être vendu, concédé sous licence ni partagé sur d’autres sites sans l’accord de son auteur.Le contenu vous est fourni TEL QUEL, pour votre information et votre usage personnel uniquement. Téléchargez la présentation en cliquant sur ce lien. Lors du téléchargement, si vous ne parvenez pas à télécharger une présentation, l’éditeur a peut-être supprimé le fichier de son serveur.Pendant le téléchargement, si vous ne parvenez pas à obtenir une présentation, le fichier a peut-être été supprimé par l’éditeur.

F I N

Plus de contenu associé

Transcription de la présentation
  1. RPC FE Electronicslongevityissue • On-detector electronics: • FE boards (~4700 Barrel; ~1300 Endcap) • Distribution board (~360 Barrel; ~ 430 Endcap) • Present status (LS1) • Can we estimate the FE behavior after LS2 and during Phase2? RPC Upgrade meeting n. 5 Flavio Loddo, INFN-Bari

  2. Status at LS1 • FE boards: worked smoothly, with few failures or malfunctioning: • 11 barrel+ 4 endcap • Distribution board: showed some fragilities (each board can control up to 3 rolls): • Barrel:  42 Rolls with TH problems (only on 16 rolls we can not control the TH). • Endcap:  12 chambers Tot. Number of activechannel 97.4% RPC Upgrade meeting n. 5 Flavio Loddo, INFN-Bari

  3. Status at LS1 • New Barrel Distribution board with improved protection was developed and produced (50 boards) • They will be used to replace the broken boards during LS1 (where possible) in the barrel chambers • Endcap chambers will be repaired with old DB. RPC Upgrade meeting n. 5 Flavio Loddo, INFN-Bari

  4. Whatabout Phase2 ? • Since the replacement of all “old” distribution board is not realistic we should expect new failures after LS1 • It’s hard to evaluate the longevity of FEBs, since at the moment their death rate is quite low • An important issue to be considered is the radiation tolerance: • FEBs have been tested up to a neutron fluence of 10^12 neutrons/cm^2, corresponding to more than 10 LHC years in the region |eta| < 1.6 • Most of the front-end electronics is analog, so SEUs would just increase the spurious noise rate by a negligible quantity RPC Upgrade meeting n. 5 Flavio Loddo, INFN-Bari

  5. Whatabout Phase2 ? From D. Piccolo’s answer to Jeff’s questions: using as reference a neutron flux between 2 and 3*10^3 neutrons/(cm^2 s) in the region around eta=1.6 at L=10^34 (muon TDR figure 10.6.3) it is possible to extract that a fluence of 10^12 neutrons/cm^2 corresponds to about 3000-5000 fb-1 In order to qualify the on-detector electronics for higher doses and fluence, a new campaign of irradiation test with neutrons/protons must be considered/planned RPC Upgrade meeting n. 5 Flavio Loddo, INFN-Bari