1 / 47

PROSTHETIC PROCEDURE MANUAL IR SYSTEM

PROSTHETIC PROCEDURE MANUAL IR SYSTEM. CEMENTED RESTORATION Implant Level Impression. Cemented Abutment. Set Screw. Impression Coping Pick -up. Implant Analog. Com Octa Plus Abutment. Angled Abutment. CEMENTED RESTORATION Abutment Level Impression. Cuff Solid Abutment. Single .

tavita
Télécharger la présentation

PROSTHETIC PROCEDURE MANUAL IR SYSTEM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PROSTHETIC PROCEDURE MANUALIR SYSTEM

  2. CEMENTED RESTORATIONImplant Level Impression Cemented Abutment Set Screw Impression Coping Pick-up Implant Analog Com Octa PlusAbutment Angled Abutment

  3. CEMENTED RESTORATIONAbutment Level Impression Cuff Solid Abutment Single Impression Coping Transfer Solid Abutment Solid Abutment Analog Bridge Wide Solid Abutment

  4. IMPRESSION COPINGSImplant Level – Pick-up 1.2mm Hex Driver Guide Pin Engaging • Implant level impression, pick-up impression coping (open tray technique) • Impression coping is packaged with corresponding guide pin • Use 1.2mm Hex driver to assemble/ disassemble

  5. IMPRESSION COPINGSAbutment Level – Transfer • Abutment level impression, transfer impression coping (closed tray technique)

  6. IMPLANT ANALOG

  7. SOLID ABUTMENT ANALOG

  8. CEMENTED ABUTMENT 1.2mm Hex Driver HEIGHT Engaging Fastening torque 30 Ncm

  9. ANGLED ABUTMENT 1.2mm Hex Driver HEIGHT Engaging Fastening torque 30 Ncm

  10. COM OCTA PLUS ABUTMENT 1.2mm Hex Driver DIAMETER HEIGHT CUFF Engaging Fastening torque 30 Ncm

  11. SOLID ABUTMENT 1.2mm Hex Driver HEIGHT Protective Cap Non Engaging Fastening torque 30 Ncm

  12. WIDE SOLID ABUTMENT 1.2mm Hex Driver HEIGHT Protective Cap Non Engaging Fastening torque 30 Ncm

  13. CUFF SOLID ABUTMENT 1.2mm Hex Driver HEIGHT CUFF Protective Cap Non Engaging Fastening torque 30 Ncm

  14. SET SCREW DIAMETER LENGTH • Cemented Abutment screw is 10mm long • Angled Abutments screw is 8mm long • Set screws are packaged along with corresponding abutment

  15. CLINICAL PROCESSFixing Impression Copings (1/3) • View of patient’s mouth

  16. CLINICAL PROCESSFixing Impression Copings (2/3) • Remove healing abutment / cover screw with 1.2mm Hex Driver • Insert impression coping inside corresponding implant connection

  17. CLINICAL PROCESSFixing Impression Copings (3/3) • Fasten impression coping with corresponding guide pin • Tighten guide pin with 1.2mm hex driver

  18. CLINICAL PROCESSTaking The Impression (1/6) • Apply the light impression material on corresponding site of oral cavity

  19. CLINICAL PROCESSTaking The Impression (2/6) • Pour the heavy impression material inside the impression tray

  20. CLINICAL PROCESSTaking The Impression (3/6) • Position tray for impression taking • Apply pressure until top part of guide pin appears • wait for impression material to set • Transfer impression copings will require prefabricated tray • Pick-up impression copings will require previously customized tray

  21. CLINICAL PROCESSTaking The Impression (4/6) • Remove guide pin

  22. CLINICAL PROCESSTaking The Impression (5/6) • Check tray for impression errors / success

  23. CLINICAL PROCESSTaking The Impression (6/6) • Replace healing abutment / cover screw in corresponding site

  24. LABORATORY PROCESS1. Fixing Analogs & Making Artificial Gum (1/4) • Fix analogs on corresponding impression coping

  25. LABORATORY PROCESS1 - Fixing Analogs & Making Artificial Gum (2/4) • Apply (Spray) separating product on impression areas

  26. LABORATORY PROCESS1. Fixing Analogs & Making Artificial Gum (3/4) • Apply artificial gum product on intervention area • Wait for product to dry

  27. LABORATORY PROCESS1. Fixing Analogs & Making Artificial Gum (4/4) • Trim gum

  28. LABORATORY PROCESS2. Master Modeling (1/3) • Prepare (mix) the stone

  29. LABORATORY PROCESS2. Master Modeling (2/3) • Pour the mixed stone inside the impression

  30. LABORATORY PROCESS2. Master Modeling (3/3) • Master model finishing work

  31. LABORATORY PROCESS3. Abutment Milling (1/5) • Fix the abutment to the analog

  32. LABORATORY PROCESS3. Abutment Milling (2/5) • Abutment Milling (Step 1)

  33. LABORATORY PROCESS3. Abutment Milling (3/5) • Abutment Milling (Step 2)

  34. LABORATORY PROCESS3. Abutment Milling (4/5) • Abutment Milling (Step 3)

  35. LABORATORY PROCESS3. Abutment Milling (5/5) • Post Milling

  36. LABORATORY PROCESS4. Pattern Resin & Wax-Up (1/3)

  37. LABORATORY PROCESS4. Pattern Resin & Wax-Up (2/3) • Wax-up process (Steps 1 & 2)

  38. LABORATORY PROCESS4. Pattern Resin & Wax-Up (3/3) • Wax-up process (Steps 3 & 4)

  39. LABORATORY PROCESS5. Sprewing (1/2) • Sprewing (Step 1)

  40. LABORATORY PROCESS5. Sprewing (2/2) • Sprewing (Step 2)

  41. LABORATORY PROCESS6. Investment (1/2) • Investment (Step 1)

  42. LABORATORY PROCESS6. Investment (2/2) • Burn out (Step 3) • Investment (Step 2)

  43. LABORATORY PROCESS7. Casting • Cast and extract cast structure

  44. LABORATORY PROCESS8. Adaptation & Metal Trimming • Check cast structure for adaptation on master model

  45. LABORATORY PROCESS9. Finishing

  46. LABORATORY PROCESS10. Transfer Jig (1/2) • Make the transfer Jig

  47. LABORATORY PROCESS10. Transfer Jig (2/2) • Place the abutment(s) inside the oral cavity by using the transfer jig

More Related