1 / 2

Assessment of Water Quality of Himayath Sagar and Osman Sagar Based on Biological Oxygen Demand

The present study was carried out to assess the water quality of Himayath Sagar and Osman Sagar based on Biological Oxygen Demand. For this study systemic sampling has been carried out by collecting 10 water samples from each lake. The collected samples were analysed for Biological Oxygen Demand using Biological Oxygen Demand Indicator BOD indicator . The results were compared with water quality guidelines for drinking as well as fishing. The mean values for both the lakes were higher than acceptable limits. Mrs. Juvaria Azmath "Assessment of Water Quality of Himayath Sagar and Osman Sagar Based on Biological Oxygen Demand" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-2 | Issue-4 , June 2018, URL: https://www.ijtsrd.com/papers/ijtsrd14375.pdf Paper URL: http://www.ijtsrd.com/biological-science/zoology/14375/assessment-of-water-quality-of-himayath--sagar-and-osman-sagar-based-on-biological-oxygen-demand/mrs-juvaria-azmath<br>

Télécharger la présentation

Assessment of Water Quality of Himayath Sagar and Osman Sagar Based on Biological Oxygen Demand

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. International Research Research and Development (IJTSRD) International Open Access Journal Assessment of Water Quality of Himayath Sagar and Osman Sagar Based on Biological Oxygen Demand n Biological Oxygen Demand International Journal of Trend in Scientific Scientific (IJTSRD) International Open Access Journal ISSN No: 2456 ISSN No: 2456 - 6470 | www.ijtsrd.com | Volume 6470 | www.ijtsrd.com | Volume - 2 | Issue – 4 Assessment of Water Quality of Himayath Sagar and Osman Assessment of Water Quality of Himayath Sagar and Osman Sagar Based o Mrs. Juvaria Azmath Lecturer, St. Ann’s College for Women, Lecturer Mehdipatnam, Mehdipatnam, Hyderabad, India low BOD is an indicator of good quality water, while a high BOD indicates polluted water. The BOD test serves an important function in stream pollution-control activities. It is a bioassay procedure that measures the amount of oxygen consumed by living organisms while they are utilizing the organic matter present in waste. ABSTRACT The present study was carried out to assess the water quality of Himayath Sagar and Osman Sagar based on Biological Oxygen Demand. For this study systemic sampling has been carried out by collecting 10 water samples from each lake. samples were analysed for Biological Oxygen Demand using Biological Indicator(BOD indicator). The results were compared with water quality guidelines for drinking as w fishing. The mean values for both the lakes were higher than acceptable limits. assess the water low BOD is an indicator of good quality water, while icates polluted water. and Osman Sagar based on Biological Oxygen Demand. For this study systemic sampling has been carried out by collecting The BOD test serves an important function in stream control activities. It is a bioassay procedure that measures the amount of oxygen consumed by living organisms while they are utilizing the organic The collected samples were analysed for Biological Oxygen Demand using Biological The results were compared with water quality guidelines for drinking as well as Oxygen Oxygen Demand Demand Methods and Methodology: 10 water samples were taken from both Himayath sagar lake and Osman Sagar lake in Hyderabad. Each sample was tested for Biological Oxygen Demand. For determining the Biological Oxygen Demand , BOD indicator has been used. The performed based on standard method for calculation of oxygen content in water .BOD is calculated by keeping the water in BOD incubator for 5 days. Dissolved oxygen is calculated both before and after keeping in BOD indicator. BOD incubator i versatile and reliable low temperature incubator which maintain a constant temperature of 20 BOD is calculated from the difference between initial and final Dissolved oxygen values. and final Dissolved oxygen values. for both the lakes were 10 water samples were taken from both Himayath sagar lake and Osman Sagar lake in Hyderabad. Each sample was tested for Biological Oxygen Demand. For determining the Biological Oxygen Demand , BOD indicator has been used. The experiment was performed based on standard method for calculation of oxygen content in water .BOD is calculated by keeping the water in BOD incubator for 5 days. Dissolved oxygen is calculated both before and after keeping in BOD indicator. BOD incubator is the most versatile and reliable low temperature incubator which maintain a constant temperature of 200C.The BOD is calculated from the difference between initial Keywords: Bioloical Oxygen Demand; oxygen; bacteria; water quality; pollution; Bioloical Oxygen Demand; dissolved pollution; water INTRODUCTION Biochemical oxygen demand is a quantitative expression of microbes ability to deplete the oxygen content of water. This depletion takes place due to the microbes consuming organic matter in the water via aerobic respiration. Aquatic organisms use dissolved oxygen to survive. If the dissolved oxygen drops to below a critical level the ecology of the streamn will be damaged. The decrease in the oxygen supply in the water has a negative effect on the aquatic life. This can lead to an increase in anaerobic bacteria that leads to the production of foul-smelling, and possibly toxic gases. These gases may include methane, hydrogen sulfide, and ammonia. If this water is consumed, there are bound to be many potential problems of toxicity to humans. Biological Oxygen Demand (BOD) is one of the most common measures of pollutant organic material in water. BOD indicates the amount of pollutants present in water. Therefore, a Biochemical oxygen demand is a quantitative expression of microbes ability to deplete the oxygen content of water. This depletion takes place due to the microbes consuming organic matter in the water via organisms use dissolved to survive. If the dissolved oxygen drops to below a critical level the ecology of the streamn will be damaged. The decrease in the oxygen supply in the water has a negative effect on the aquatic life. This o an increase in anaerobic bacteria that Formula : N1V1=N2V2 smelling, and possibly toxic gases. These gases may include methane, hydrogen sulfide, and ammonia. If this water is there are bound to be many potential Where N1=Normality of oxygen Where N1=Normality of oxygen V1=Volume of sample Biological Oxygen N2=Normality of Hypo or Sodium thio sulphate N2=Normality of Hypo or Sodium thio sulphate Demand (BOD) is one of the most common measures of pollutant organic material in water. BOD indicates the amount of pollutants present in water. Therefore, a V2=Volume of Hypo or Sodium thio sulphate V2=Volume of Hypo or Sodium thio sulphate @ IJTSRD | Available Online @ www.ijtsrd.com @ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 4 | May-Jun 2018 Jun 2018 Page: 1857

  2. International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470 Amount of oxygen in ppm =N1x 8x1000 Conclusion: The BOD values of Osman Sagar and Himayathsagar were found to be more than the normal BOD value for drinking water. The Lakes are being polluted by Human Intervention. As the BOD levels are more fishes and other aquatic organisms may not survive. BOD=D1-D2 D1=Initial dissolved oxygen D2=Final dissolved oxygen. References Result: The BOD value of Osman Sagar water was found to be 4 ppm and the BOD value of Himayath Sagar was found to be 3.2. The normal BOD value for drinking water should be less tha 3 according to BIS(Bureau of Indian Standards) 1.Ecology by P. D. harma 2.https://www.researchgate.net/file.PostFileLoader. html?id... assetKe 3.https://en.wikipedia.org/wiki/Hyderabad_city_lak es @ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 4 | May-Jun 2018 Page: 1858