STANDARDI U AUDIOMETRIJI, BAŽ DARENJE AUDIOMETARA, PRIPREMA DECE ZA AUDIOMETRIJU

STANDARDI U AUDIOMETRIJI, BAŽ DARENJE AUDIOMETARA, PRIPREMA DECE ZA AUDIOMETRIJU. Aktiv za audiologiju i otoneurologiju, 16.05.2006. Branka Miki ć Institut za ORL i MFH Klinicki centar Srbije. Prikaz audiograma. Na jednom grafikonu (ASHA)

tejano
Télécharger la présentation

STANDARDI U AUDIOMETRIJI, BAŽ DARENJE AUDIOMETARA, PRIPREMA DECE ZA AUDIOMETRIJU

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. STANDARDI U AUDIOMETRIJI, BAŽDARENJE AUDIOMETARA, PRIPREMA DECE ZA AUDIOMETRIJU Aktiv za audiologiju i otoneurologiju, 16.05.2006. Branka Mikić Institut za ORL i MFH Klinicki centar Srbije

  2. Prikaz audiograma • Na jednom grafikonu (ASHA) • Na dva grafikona (Jerger), desno uvo na levoj strane papira, a levo na desnoj strani • Dvobojni: desno-crveno, levo- plavo • Simbolima: vazdušna desno kružići, vazdušna levo X, spojeni celom linijom; koštana desno obrnuta streliica, levo strelica, spojeni isprekidanom linijom

  3. BILATERALNA KONDUKTIVNA NAGLUVOST

  4. Grafikon audiograma • Frekvencijski opseg od osam oktava od 128 Hz do 8192 Hz za vazdušnu, odnosno od 256 do 4 kHz za koštanu provodljivost • Kod visokotonske audiometrije do 16 kHz • Intenzitet od 0 do 120 (100) dBSPL • 20 dB SPL odgovara normalnom sluhu (0 dB HL)

  5. NORMALAN AUDIOMETRIJSKI NALAZ • Prag bolji od 20 dB u frekventnom opsegu 125 do 8192 Hz • SDS 86-100% • Potrebni su finiji testovi govorne diskriminacije da bi se isključila diskretna centralna patologija (APD i sl.)- Jerger,1993

  6. BAŽDARENJE-KALIBRACIJA AUDIOMETARA • Provera tačnosti emitovane frekvencije i intenziteta • Svakodnevno: automatski ili ručno pre početka rada • Periodično, na 6 -12 m: uz pomoć ugrađene elektronike ili spoljne akustičke opreme • Pri promeni slušalica • Zakonska obaveza u EU i SAD

  7. KALIBRACIJA AUDIOMETARA Kalibracija se vrši uvek u kompletu: audiometar i odgovarajuci "predajnik" - transdjuser (vazdušna provodljivost,najčešće TDH 39, koštana provodljivost, najčešće B71, insert phones E-A-RTONE, free field...)

  8. KALIBRACIJA AUDIOMETARA • Od opreme za kalibraciju potrebno je imati precizan Sound Level Meter, koji zadovoljava uslove standarda IEC 651 Type 1 • Akustičke kaplere, 6cc i 2 cc koji zadovoljavaju standarde IEC 308 i IEC 126. • 1" mikrofon za navedene kaplere koji zadovoljava IEC 1094-1. • Veštački mastoid (Artificial mastoid) koji zadovoljava IEC 373. • U principu kalibracija se vrši tako što se signal iz transdjusera očitava na Sound Level Metru, a zatim se softverski vrši podešavanje na audiometru. • Kalibracija se vrši po pojedinačnim frekvencijama i jačinama.

  9. KALIBRACIJA AUDIOMETARA • Kod novih audiometra, postupak kalibracije je automatizovan, obavlja se softverski, bez otvaranja kućišta audiometra. Svaki proizvodjač uz odredjeni model daje i protokol kalibracije. • Važno je da se kalibracija vrši u kompletu: audiometar - transdjuser. U slučaju da dodje do zamene slušalica na audiometru, potrebno je uraditi novu kalibraciju. Ukoliko dodje do pada slušalica na pod ili do jakog udarca, preporučuje se kontrola i eventualna vanredna kalibracija • Kod novijih audiometara moguće je izvršiti kalibraciju za više vrsta transdjusera: npr. slušalice i insert phone. Parametri se pamte prema vrsti transdjusera, audiometar koristi odgovarajuće. • Kalibracija bi trebalo da se vrši jedanput godišnje. Na zapadu se to strogo sprovodi, a takodje i svaki proizvodjač navodi redovnu kalibraciju kao obaveznu proceduru

  10. PRIPREMA DECE ZA TONALNU AUDIOMETRIJU • Tonalna liminarna audiometrija kod dece od 4. godine starosti • Na mlađem uzrastu specifične pedijatrijske audiometrijske metode (VRA, PCA, PSHB i dr) • Psihološka priprema • Višednevno kondicioniranje • Korišćenje specijalnih slušalica kod veoma male dece (insert earphones) • Masking se ne radi kod dece mlađe od 6 godina

  11. AUDIOMETRIJSKO ISPITIVANJE DECE • BATERIJA TESTOVA • Poređenje praga dobijenog ponovljenom tonalnom audiometrijom, sa pragom akustičkog refleksa, nalazima BERA-e, TEOAE, DPOAE • “Cross-Check Principle” – Jerger, 1976