An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ATLAS EM Calorimeter Jackson Choate

  2. ATLAS Calorimeters

  3. The Science Behind It… • High-energy electrons and photons lose energy primarily through Bremsstrahlung and pair production, respectively. • Bremsstrahlung and pair production produce more electrons and photons at lower energies.

  4. Science (cont.) We see that for denser media, photons are more likely to produce electron-positron pairs and electrons lose energy predominantly through Bremsstrahlung

  5. Science (cont.) The denser the media, the less energy more massive charged particles lose per unit length.

  6. EM Calorimeter Design • To measure the energy of lighter charged particles and photons, a dense absorber needs to be used with an ionizable medium. • Solution? Lead sheets clad in stainless steel with a liquid argon medium. • Showers in the argon liberate electrons to be collected and recorded. • Argon has the property of being resistant to ionizing and neutron radiations.

  7. EM Calorimeter Barrel

  8. EM Calorimeter Accordion “Accordion” structure allows for faster readings and reduced dead zones while providing a radiation depth of 24 Xo.

  9. EM Calorimeter Accordion (cont.)

  10. EM Calorimeter End-Cap EM Calorimeter End-Cap uses the same accordion structure as the barrel, but positioned orthogonally in a “Spanish Fan” configuration. However, due to the orientation of the end-caps, this will produce variations in the distance traveled by cascades and affect measurements.

  11. To minimize the effects of the sampling fraction and argon gap variations, the high voltage (which defines drift velocity) is varied. • This causes the average drift velocity to remain constant throughout the calorimeter.

  12. Barrel & End-Cap Setup

  13. EM Cryostat Cryostat maintains the -185 o C temperature to keep the liquid argon from becoming a gas.

  14. EM Calorimeter Data Collection Simulated result of shower inside of the EM Calorimeter Accordion

  15. Presampler – Single thin layer of liquid argon to correct for energy losses in Inner Detector 1st Sampling – Provides excellent resolution for photon/neutral pion separation 2nd Sampling – Clusters below 50 GeV are fully contained 3rd Sampling – Only the highest energy electrons will reach this deep

  16. EM Calorimeter Data Collection Electrodes are kept at a potential of +2000 V, creating an electric field of 1 MV/m between the absorber and the electrode.

  17. Signals collected at the electrodes are transferred through vacuum-sealed tubes called “feedthroughs.” • These feedthroughs are designed to preserve the signal during the transition from the cold liquid argon to the warmer electronics area.

  18. Schematic of an end-cap feedthrough

  19. Energy Resolution of EM Calorimeter As seen, the EM Calorimeter has a very precise energy resolution. It’s spatial resolution is also very precise, capable of measuring pseudorapidity and perpendicular plane angles within 0.025 radians.

  20. Works Cited • D. M. Gingrich et al. Performance of a large scale prototype of the ATLAS accordion electromagnetic calorimeter. Nucl. Instrum. Meth., A364:290-306, 1995. • Egede, Ulrik. "The liquid argon calorimeter." N.p., 08 Jan 1998. Web. 3 Nov 2010. <http://www.hep.lu.se/atlas/thesis/egede/thesis- node43.html>. • Froidevaux D, Sphicas P. 2006. Annu. Rev. Nucl. Part. Sci. 56:375 – 440 • Krieger, Peter. "The ATLAS Liquid Argon Calorimeter." University of Toronto, 26 OCT <http://www.physics.utoronto.ca/~krieger /talks/Krieger_NSS05_Talk.pdf> • P. Schwemling. The European Physical Journal C - Particles and Fields Volume 34, Supplement 1, s129-s137, DOI: 10.1140/epjcd/s2004-04-014-x