An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MidNiteSolar’s Pre wired solutionsfor Off Grid, Battery based Grid tie and AC coupled. MidNite Solar 360-403-7207

  2. Ryan, Technical Support Manager ryan@midnitesolar.com 360-403-7207 XT151 MidNite Solar 360-403-7207

  3. What type of system doI need?*Off Grid. *Battery Based Grid Tie.*AC Coupled.All of MidNiteSolar’s Pre Wired systems are fully customizable for your needs MidNite Solar 360-403-7207

  4. *Stand alone system *Will not sell back to the utility *Various inverters available for Off Grid (Some will do both) *120 or 120/240? Off Grid MidNite Solar 360-403-7207

  5. Grid Tie with Battery backup *Sells to the grid *Runs critical loads during grid failure *Do you need 120vac or 120/240vac *Some models support generator input as well MidNite Solar 360-403-7207

  6. AC Coupled *Adds battery backup to a purely grid tie system. *Adds some complexity to the system. *Best suited for existing grid tie systems as an add on. MidNite Solar 360-403-7207

  7. *Growing market segment *Can be confusing! *Can be complicated! *Numerous ways to go *MidNitehas taken most of the mystique out of the equation AC Coupled MidNite Solar 360-403-7207

  8. AC Coupling is a controlled back feed to a battery based inverter A back feed is hooking up AC to the output of an inverter AC coupling is a synchronized back feed. The grid tie inverter shifts frequency to match the battery based inverter before connecting. This makes it ok to do What is AC Coupled ? MidNite Solar 360-403-7207

  9. Not all battery based sinewave inverters are capable of backfeed. Your choices in North America are: SMA Sunny Island Outback FX, VFX and Radian Magnum PAE series Schneider XW series What is AC Coupled ? MidNite Solar 360-403-7207

  10. *Magnum and OutBack inverters sense circuits that control charging are on the AC inputs not the output, therefore cannot controlthe charging *These inverters charge wide open and cannot taper off. *A relay is required to disconnect the GT What is AC Coupled ? MidNite Solar 360-403-7207

  11. *SMA and Schneider use frequency shift to knock the GT inverter offline to stop the charging. *The Sunny Island will control a Sunny Boy to do tapered charging. What is AC Coupled ? MidNite Solar 360-403-7207

  12. *Radian and the Schneider have 2 AC inputs so a generator can be added. *Provisions must be added to disconnect the GT inverter when the generator runs or the GT will try to sell to the Inverter. Generators and AC Coupled MidNite Solar 360-403-7207

  13. *Outback, Magnum and Schneider have a 1:1 ratio limit. *SMA has a 2:1 ratio *The customer may not need all of the grid tie solar as part of the ac coupled. Sizing of the Off Grid inverter MidNite Solar 360-403-7207

  14. Outback FX series *120 vac per single unit. *Either Grid tie or Off Grid not both. Both AC couple. *Grid tie models (G series) does not play well with generators. *Smaller scale and expandable. *12,24 and 48VDC models available MidNite Solar 360-403-7207

  15. Quad Off Grid Outback Prewired MidNite Solar 360-403-7207

  16. Outback Radian *Grid tie or Offgrid Supports both AC coupled as well *120/240 in a single unit *Has 2 AC inputs (2nd for generator) *8,000 watts per unit, Stackable *48VDC model *Requires relays for AC coupled MidNite Solar 360-403-7207

  17. Outback Radian MidNite Solar 360-403-7207

  18. Outback Radian MidNite Solar 360-403-7207

  19. Magnum Energy *120vac and 120/240vac models (Only the 120/240 PAE should be used for AC coupled)*various wattage inverters available*Stackable*Vented only*Off Grid only (AC coupled)*12, 24 and 48VDC models MidNite Solar 360-403-7207

  20. Magnum Energy MidNite Solar 360-403-7207

  21. Magnum Energy MidNite Solar 360-403-7207

  22. Magnum Energy MidNite Solar 360-403-7207

  23. Xantrex XW *Grid tie or Off grid. Supports both*120/240 in a single unit*Has 2 AC inputs (2nd for generator)*4.5KW or 6KW units, Stackable*24 or 48VDC models MidNite Solar 360-403-7207

  24. SMA Sunny Island *Grid tie or Offgrid. Supports both*120VAC*Single input but we offer an automatic transfer switch for generator backup.*4.5KW or 6KW units, Stackable*48VDC MidNite Solar 360-403-7207

  25. SMA Sunny Island MidNite Solar 360-403-7207

  26. Questions? Ryan Stankevitz MidNite Solar 360-403-7207 XT 151 ryan@midnitesolar.com