1 / 13

Oxidative Degradation and the Oxidation-Reduction Potential of ROC20 Solutions

Oxidative Degradation and the Oxidation-Reduction Potential of ROC20 Solutions. By Fred Closmann January 10, 2008. Summary of Topics Covered. What is Oxidation-Reduction Potential (ORP)? Why we want to Measure ORP? How ORP Can Help US? Review Preliminary Data (ROC20)

thimba
Télécharger la présentation

Oxidative Degradation and the Oxidation-Reduction Potential of ROC20 Solutions

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Oxidative Degradation and the Oxidation-Reduction Potential of ROC20 Solutions By Fred Closmann January 10, 2008

  2. Summary of Topics Covered • What is Oxidation-Reduction Potential (ORP)? • Why we want to Measure ORP? • How ORP Can Help US? • Review Preliminary Data (ROC20) • Other Findings – High Viscosity Solvent • Possible Future Experiments

  3. ORP • According to ASTM method, “the ORP measurement establishes the ratio of oxidants and reductants prevailing within a solution… allows determination of the ability to oxidize or reduce species in solution.” • Reacting species related by Nernst Equation. • Non-selective; all e-transfer reactions influence measurement. • Gross measurement - not initially concerned with exact chemistry. • Standardized method(s) (ASTM)

  4. ORP Electrode Standard Hydrogen Electrode We are using Ag/AgCl reference

  5. Where is the degradation most likely to occur? Gas w/ 1% CO2 CO2 H2O, O2 Absorber 40-70 °C 1 atm Stripper 120 °C 1 atm Absorber Packing Cross Exchanger Sump Reboiler Flue Gas 10% CO2 5-10% O2 Solvent  = 0.4

  6. Why Measure ORP? • Oxidative degradation can occur in the mass-transfer controlled region (Goff). • Allow us to know the potential for and rate of degradation of solvents. • Goal: Develop correlation between ORP and solvent degradation rate. • Secondary Goal: Understand catalytic effect of metals on solvent oxidation. • Real-time data collection (on-line methods).

  7. Experiments Conducted to-Date • Baseline: ROC20 formulations (loaded to 0.3 mole/mole based on alkalinity) aerated/stirred in glass reactor at 53.5 °C. • Loaded ROC20 solution augmented with 0.01 mM Cu (added as cupric sulfate). • Rapid shut-down of well-mixed/aerated reactor with loaded ROC20 to understand O2 consumption (absence of copper). • Rapid start-up of reactor (aeration and mixing) from quiescent state (absence of copper). • Viscosity measurements of loaded ROC20 solutions

  8. Steady-State Results • *ROC20 solution sat idle in reactor for 3 weeks. • **Viscosity measurements made at 25/40 °C. • NM – Not measured, NA – Not Applicable.

  9. Interpretation of Results • Negative ORP not necessarily reduced environment. • Oxygen depleted fast; 90% of ORP change occurs in 24 minutes in quiescent reactor. • Rapid increase (<3 min) in ORP to near-steady state condition (-185 mV) upon reactor start-up. • Copper increases ORP; consistent with previous observations related to formate production (Sexton, 2007). • ROC20 became more viscous after sitting idle (305 cp vs. 18 cp at 25 °C); observation confirmed in experiment without Cu.

  10. Potential ORP Experiments • Change reactor conditions improved mixing/aeration, and absence of both. • Addition of metals species including Ferric/Ferrous Iron to ROC20 to observe iron shuttle effect on ORP. • Addition of cobalt and nickel to investigate catalytic effects on ORP. • Addition of Hydrogen Peroxide (H2O2) to create highly oxidative environment - measure ORP and degradation of ROC20.

  11. Investigate Potential ROC20 Polymerization Mechanisms • Recreate steps that lead to formation of highly viscous ROC20. • Repeat with ROC20 and other solvents. • Analysis using ORP, cation/anion chromatography, NMR, titration. • Reversible condition? Heat to 120 °C to mimic stripper operation. • Investigate CO2 stripping effects of experiments. Reload back to 0.3 m/m to reverse condition – (completed). • Literature review – formation of urea compound or polymer based on ROC20; propose pathway to creation of polymer.