1 / 6

MD 25 ns 24/10/2011 Beam 1: 2098 bunches Beam 2: 804 Bunches Average intensity ≈ 8E10 p/b

MD 25 ns 24/10/2011 Beam 1: 2098 bunches Beam 2: 804 Bunches Average intensity ≈ 8E10 p/b G. Bregliozzi TE-VSC-LBV. Gauges in the MKI 1 and 4 in LSS2. 25 ns – Beam 1: 2098 bunches – Beam 2: 804 Bunches – 8E10 p/b. A. D. Solenoid ON/OFF. 1. 4. A. 1. 4. D.

toyah
Télécharger la présentation

MD 25 ns 24/10/2011 Beam 1: 2098 bunches Beam 2: 804 Bunches Average intensity ≈ 8E10 p/b

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MD 25 ns 24/10/2011 Beam 1: 2098 bunches Beam 2: 804 Bunches Average intensity ≈ 8E10 p/b G. Bregliozzi TE-VSC-LBV

  2. Gauges in the MKI 1 and 4 in LSS2 25 ns – Beam 1: 2098 bunches – Beam 2: 804 Bunches – 8E10 p/b A D Solenoid ON/OFF 1 4 A 1 4 D Pressure in the MKI at the extremities limited by the degassing of the cold-warm transition of Q4 and Q5

  3. Gauges in the MKI 2 and 3 in LSS2 25 ns – Beam 1: 2098 bunches – Beam 2: 804 Bunches – 8E10 p/b Injected Beam A – B – C 2 3 A B C 3 2 Pressure in the MKI 2 and 3 independent of the interconnecting modules and no pressure increase due to the injected beam

  4. LSS 2 Gauges in the interconnecting modules MKI – Circulating Beam 25 ns – Beam 1: 2098 bunches – Beam 2: 804 Bunches – 8E10 p/b E A 3 A B C D E Pressure in the interconnecting modules (circulating beam) independent reading. Maximum pressure increase in the extremities due to the cold-warm transition Q4-Q5

  5. For the LSS8 • Difficult to define any correlations

  6. Summary from the 25 ns MD: • The presence of the two beams is not allowing a detailed and precise analysis of the effects of the injected beam or circulating beam. • MKI 1 and 4 see pressure increase in the cold warm transition of Q4 and Q5: factor 2 lower. • MKI1 and MKI 4 presents the highest pressure increase • The vacuum of each MKI is generally independent from the adjacent.

More Related