PS Ventilatio n - Run mode results -

PS Ventilatio n - Run mode results -. Boundary conditions / assumptions:. Air recirculation system (RVS) and fresh air system ( FAVS) are working.

trevet
Télécharger la présentation

PS Ventilatio n - Run mode results -

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PS Ventilation - Run mode results - 2013-01-16

  2. Boundary conditions / assumptions: • Air recirculation system (RVS) and fresh air system (FAVS) are working. • The inlet and outlet surfaces for the RVS will be set at two couples of 0.1 m wide continuous rings placed on the floor (at the sides of the magnet) and at the ceiling • Air flow rates: FAVS: 4000 m3h-1atTechnical Rooms inlets, 5000 m3 h-1 at the center of the ringRVS: 40000 m3 h-1at TR1 and TR2, 30000 m3 h-1other TRs. • Same pressure at all the air outlets. • Tunnels leaks not taken into account. • Buoyancy and heat transfer neglected. 2013-01-16

  3. Conventions Nominal flow rates + + + + • “r45” means flow rate in the tunnel between the technical room 4 and 5. • Flow rate in tunnels (r12, r23, etc.) is positive when counter-clockwise. • Flow rate in galleries is positive when moving radially from the ring center to the outside. 2013-01-16

  4. Inlet layouts Standard Straight-15 Magnet-15 • Flow perpendicular to the inlet. • Perpendicular flow in the left-half of the inlet. • Flow oriented 15° to the right in the right-half. • Flow oriented 15° to the left in the left-half. • Flow oriented 15° to the right in the right-half. • Flow directed downwards in order to impinge the bottom of the magnet. 2013-01-16

  5. Tunnels flow rates • Nominal case: ideally, the air at inlets is expected to evenly split 50% right and 50% left. • With the “Standard” inflow layout, air impinges the wall in front of the inlet, and a swirling counter-current flow occurs. • With the „Straight – 15” the flow is split but still more is going to counter-clock direction. • Only with the “Magnet-15” layout, the air coming from the technical rooms splits to the left and the right. • Volume average velocity Magnitude: Standart – 0,1184 m/s, Straight-15 – 0,1115 m/s, Magnet-15 – 0,1066 m/s 2013-01-16

  6. Galleries flow rates • Nominal flow rates were expected to be: • +2750 m3h-1 at big galleries (g1, g3, g5,g7) • - 1500 m3h-1at small galleries (g2, g4, g6,g8) • CFD results are very different from nominal case and seem to be very sensitive on the inlet layout. • Important to keep an high average velocity in all the galleries in order to extract the activated air. • Globally, the “magnet-15” layout displays the highest average velocity in the galleries (~0.09 m s-1vs ~0.05 m s-1 ) 2013-01-16

  7. Velocity profile z=2 and z=3 Standard Straight-15 Magnet-15 2013-01-16

  8. Velocity profile r12 Standard Straight-15 Magnet-15 2013-01-16

  9. Pathlines „Standard” FAVS RVS R12 R4 2013-01-16

  10. Pathlines „Straight-15” FAVS RVS R12 R4 2013-01-16

  11. Pathlines „Magnet-15” FAVS RVS R12 R4 2013-01-16

  12. Conclusions • „Standard” model is still counter clock wise • The closest to the nominal one is the „Magnet – 15” model • Low velocities in the galleries (the best with Magnet – 15) 2013-01-16