HORIBA Portable Meter Line-up

HORIBA Portable Meter Line-up. HORIBA Benchtop Meter Line-up. HORIBA Pocket Meters. TWIN Series (pH, Conductivity) Pocket-size HORIBA flat sensor meter. TWIN pH meter is waterproof, suitable for lab and field use. Replaceable sensor. pH. Conductivity.

troy-baird
Télécharger la présentation

HORIBA Portable Meter Line-up

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HORIBA Portable Meter Line-up

  2. HORIBA Benchtop Meter Line-up

  3. HORIBA Pocket Meters

  4. TWIN Series (pH, Conductivity) • Pocket-size HORIBA flat sensor meter. • TWIN pH meter is waterproof, suitable for lab and field use. • Replaceable sensor. pH Conductivity

  5. Cardy Series (Salt, NO3-, K+, Na+) • HORIBA flat sensor technology is available in pocket-size. • World’s only pocket-size Ion meter for lab, agriculture, food, environmental study, etc. • Sensor replaceable. Ion

  6. HORIBA Portable Meters

  7. OM series (OM-51-2/-10/-lab) • Portable single parameter meter to measure Dissolved Oxygen. • No optional unit necessary for RS-232C, AC or printer connection. • Compact design, larger LCD with IP67 rated waterproof realizes easy use in the field • Data storage up to 300 sets with time stamp. Temperature O2 DO

  8. ES-50 series (ES-51) • Portable single parameter meter to measure Conductivity. • No optional unit necessary for RS-232C, AC or printer connection. • Compact design, larger LCD with IP67 rated waterproof realizes easy use in the field • Data storage up to 300 sets with time stamp. Salinity Temperature Resistivity Conductivity

  9. D-50 series (D-51,52,53,54,55) • Portable Multi-Parameter meter to simultaneously measure pH and ORP/Ion/Conductivity/DO. • No optional unit necessary for RS-232C, AC or printer connection. • Compact design, larger LCD with IP67 rated waterproof realizes easy use in the field • Data storage up to 300 sets with time stamp. Ion ORP pH Conductivity DO Temperature

  10. U-20 series (U-22, W-22/23) • Portable Multi-Parameter meter to simultaneously measure up to 13 water quality parameters. • Cable length up to 100 m with waterproof rating of IP67 • One-touch calibration makes work easy • Up to one month monitoring • Heavy-duty probe fits into 2-inch well. (flowcell option available) • Expandability to printer, RS-232 and GPS unit Ion (select 3 from 6 options) ORP pH Conductivity DO Temperature Salinity Seawater Specific Gravity Depth TDS Turbidity

  11. Benchtop Meters

  12. DS-50 series (DS-51, DS-52) • Benchtop single parameter meter to measure Conductivity • RS-232C output standard • Battery operation possible for portability. • D-52 with color display and navigation features Salinity Temperature Resistivity Conductivity

  13. F-50 series (F-51BW, 52, 53, 54, 54BW, 55) • Extended GLP/GMP compliance with World’s Firstmeter to comply 21CFR Part11 requirements. • World’s First benchtop meter with color LCD display • World’s First meter with Compact Flash interface. • User friendly navigation features full of HORIBA’s 50 years experience • Meter checker available to verify meter performance • RS-232C output standard for all models. • Battery operation possible for portability. Temperature Ion Conductivity ORP pH Salinity Resistivity

  14. HORIBA Sensor Technology

  15. New ToupH Series Electrode • HORIBA Introduced ToupH 9610-10D electrode • 2003 HORIBA Introduces ToupH family with… • Ag+ Trap Technology No Ag+ spill, long lasting • ToupHer Design Shorter and wider

  16. Ag+ Trap Technology No Ag+ spill, long lasting Ion exchange material traps Ag+ and prevents Ag+ from spilling into the internal solution Ag+ within the internal solution saturates and clogs the liquid junction • Slow Response • Ag+ Contaminates sample • Maintained Fast Response • No Ag+ Contamination New Former KCl Internal Solution Ag/AgCl Electrode KCl Internal Solution Ag/AgCl Electrode Pin hole to Teflon Coating Ion exchange material Liquid Junction Pin hole to Teflon Coating Liquid Junction

  17. Ag+ Trap Technology 3 months monitoring in Protein Sample

  18. Ag+ Trap Technology 3 months monitoring in Tap Water The response is 40 times faster 10 5 mV 0 Conventional -5 New -10 0 300 600 900 1200 1500 1800 time(s)

  19. ToupHer Design Shorter and Wider New Conventional 11mm 15mm φ8mm φ6mm • Strength increased by 4.4 times more than former ToupH electrode. Doesn’t break from 1m height. • Now stronger against impact from all sides • Requires less sample volume • Available as ToupH Family: General purpose, Sleeve and Micro pH electrodes

  20. Electrode Comparison HORIBA vs. Accumet (13-620-285) HORIBA Accumet • Response • Due to no solution made for Ag+ spill, the response time will become slow in a few months. • Strength • Not a durable design, breaks from 10cm height. • Temperature accuracy for pH measurement • Temperature detected at G pole and the actual temperature at R pole may differ →unreliable pH value

  21. Electrode Comparison HORIBA vs. Mettler HORIBA Mettler HORIBA Stabilizes in 3 minutes • Response • Due to the storage in KCl solution, response against tap water is very slow. METTLER Stabilizes in 9 minutes *Stabilization: Within 0.01pH drift in 1 minute

  22. 8 HOR9611 ORION8202 7.5 40℃ Initial ORION8272 2 days 7 Room Temp. pH Room temp. 6.5 1 hour 1 hour 6 5.5 5 Electrode Comparison HORIBA vs. ORION (8202, 8272) HORIBA ORION • Strength • Not a durable design, breaks from a certain height. • Stability • pH value drifted by 0.5 pH when applied temperature drift test. 0.5pH

  23. Electrode Comparison Summary HORIBA METTLER ORION WTW FISHER TOADKK InLab 410 InLab 413 #9611 GST- 13-620- #9610 8202 8272 SenTix61 Sentix20 5731C (old) (new) 285 ROSS/ Accumet Strong・pH ROSS Sure-Flow standard Glass Strong・ Superior Superior ToupH ToupH electrode pH durability durability Filling Feature Solid Platinum Silver Silver Reference solution Filter Gel polymeric electrode electrode ion trap ion trap saturated electrolyte with Ag Tap water response ◎ × ◎ × × ○ ◎ × × × (after three months) Durability ◎ ○ ○ ◎ × △ △ × ◎ × Ranking No.1 No.7 No.2 No.3 No.8 No.5 No.3 No.8 No.5 No.8

  24. Micro ToupH (9669-10D) World’s smallest w/temp. sensor 1.No sample contamination Ag+ Trap Technology No contamination! In the past… Internal solution ooze out from Liquid junction, contaminating the sample 2.Unbreakable ToupH Design Strength even breaking the beaker! In the past… Electrode hit stirrer or beaker and broke 3.High Precision Built-in Temperature Sensor Reliable measurement! In the past… Calibration in room temperature →measurement at 37℃ pH0.1error against pH4 solution 4.For microvolume or Precious samples In the past… Enough volume of precious or large container has to be prepared 3mm diameter sensor Requires only 0.3ml of your sample

  25. ToupH Sleeve (9677-10D) Ideal for viscous or slurry sample 1.No sample contamination Ag+ Trap Technology No contamination! In the past… Internal solution ooze out from Liquid junction, contaminating the sample 2.Unbreakable ToupH Design Strength even breaking the beaker! In the past… Electrode hit stirrer or beaker and broke 3.Works with difficult samples Slurry Design Viscous sample still contacts with liquid junction, cleaning is also easy In the past… Hard to measure viscous sample (does not come in contact with liquid junction) or slurry sample (clogs the liquid junction)

  26. ISFET Electrode (0030-10D) Ideal for food measurement 1. Easy maintenance ・No need to replace or refill KCl internal solution ・Just replace a tip when sensor is consumed Easy to use 2. Ideal for food measurement ・Food additives (CMC, Glycerine, KCl) is used for internal solution ・Glass will not break into sample (food) ・Tip design allows for easy sample entry For meat and fruit 3. Minimize running cost ・Replaceable tip makes it economical and environmentally friendly. Just replace the tip!

  27. Optional Products Cleaning Reagent Model #220 10% Thiourea, 1% HCl Effective for liquid junction cleaning, removing contamination from inorganic sample Over 50% of electrodes recovers, based on HORIBA experience. Digital Simulator Model X-51 Digital Simulator Model X-52 Checks meter performance Gives simulation signal to the meter (for Conductivity check ) Checks meter performance Gives simulation signal to the meter (for pH, mV, Ion, DO check ) Electrode Stand For Portable meters AC Adatper For Portable meters Ink Printer For GLP/GMP compliance