Ethernet Temperature & Humidity Data Logger for remote monitoring

Measure and Record 2 Temperature Readings Using External Sensors<br>-40°C to 110°C Temperature Recording Range with ±0.3°C Temperature Accuracy<br> Configure, Setup and Manage Data Loggers over an Internet Connection and Browser<br>Free WebStorage Service, WebViewer and Current Readings Monitor Software IncludedPhone call, Email & SMS alert system (optional)<br> Stores up to 8,000 Sets of Recorded Readings onto Internal Non-Volatile Memory<br>User-Configurable Sampling Rate: 1 Second to 1 Hour<br>Email Alarm Notifications and Optional External Contact Terminal for Electromagnetic Contactor<br>AC Powered with Battery Backup for Power Failures and Emergency Use Only <br>Automatic Sending of Measured Readings via FTP or E-mail<br>

Télécharger la présentation

Ethernet Temperature & Humidity Data Logger for remote monitoring

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 14 May 2015 Ethernet Temperature & Humidity Data Logger for remote monitoring Features >> Measure and Record 2 Temperature Readings Using External Sensors >> -40°C to 110°C Temperature Recording Range with ±0.3°C Temperature Accuracy >> Configure, Setup and Manage Data Loggers over an Internet Connection and Browser >> Free WebStorage Service, WebViewer and Current Readings Monitor Software Included >>Phone call, Email & SMS alert system (optional) >> Stores up to 8,000 Sets of Recorded Readings onto Internal Non-Volatile Memory >> User-Configurable Sampling Rate: 1 Second to 1 Hour >> Email Alarm Notifications and Optional External Contact Terminal for Electromagnetic Contactor >> AC Powered with Battery Backup for Power Failures and Emergency Use Only >> Automatic Sending of Measured Readings via FTP or E-mail Specifications TR-701NW / 701AW TR-702NW / 702AW TR-702NW-H / 702AW-H TR-0106 THA-3151 HHA-3151(High-Precision Type) Temperature/Humidity Sensor (External) Polymer Resistance Platinum Resistance Electrostatic Capacitance Thermistor Thermistor Temperature 2ch Temperature 1ch Humidity 1ch Temperature 1ch Measurement Channels Humidity 1ch °C, °F °C, °F %RH °C, °F %RH Measurement Units -40 to 110°C(Supplied Sensor) -60 to 155°C(Optional Sensor: Fluoropolymer Coated Type) 10 to 95%RH 0 to 55°C -30 to 80°C 0 to 99%RH Measurement Range ±2.5%RH [at 25°C, 10 to 85%RH] ±4.0%RH [at 25°C, 0 to 10%RH or 85 to 99%RH] At temperatures other than 25°C and ≥ 0°C, add ±0.1%RH per degree of difference from 25. Humidity Hysteresis: ±1.5%RH or lower *1 Avg. ±0.3°C [- 20 to 80°C] Avg. ±0.5°C [- 40 to -20 / 80 to 110°C] ±0.3°C [0 to 50°C] ±0.5°C [at all other temperatures] ±5%RH [at 25°C, 50%RH] ±0.5°C Accuracy Measurement Resolution 0.1°C 0.1°C 1%RH 0.1°C 0.1%RH Thermal Time Constant: Approx. 75sec. Response Time (90%): Approx. 7min. Response Time (90%): Approx. 7min. Response Time (90%): Approx. 20sec. Responsiveness Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:sales.uae@vackerglobal.com www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

  2. 14 May 2015 Response Time (90%): Approx. 190sec. 8,000 data sets (One data set consists of readings for all channels in that type of unit.) Logging Capacity Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. Recording Interval Endless (Overwrite oldest data when capacity is full) Recording Mode Measurements (alternating display), Power Warning Mark, etc. LCD Display Items TR-701NW / 702NW: Wired LAN RJ45 Connector 100 Base-TX / 10 Base-T AutoMDI / MDI-X TR-701AW / 702AW: Wireless LAN Internal wireless LAN antenna IEEE 802.11b/g WEP(64bit/128bit) / WPA-TKIP/WPA2-AES USB Communication (For Setup) Communication Interfaces <Output Terminal: Photo Mos Relay Output> Voltage when OFF: AC/DC less than 50V Current when ON: less than 0.1A Resistance when ON: about 35Ω External Alarm Terminal HTTP, SMTP (POP before SMTP, SMTP-AUTH <LOGIN>), FTP, SNTP, DHCP, DNS Communications Protocol Main Power: AC Adaptor (AD-0638 or AD-0638-C) / Backup Power: Coin Type Lithium Battery (CR-2032) *2 Power Approx. 3 months (backup battery CR-2032 only without AC adaptor) Data Backup *3 H 55 mm x W 78 mm x D 37 mm Dimensions TR-701NW / 702NW / 702NW-H : approx. 82 g TR-701AW / 702AW / 702AW-H : approx. 80 g (including battery, excluding sensor) Weight Temperature: -10 to 60°C Humidity: 90 %RH or less (no condensation) Operating Environment High Precision Temperature/Humidity Sensor (HHA-3151) x 1 Temperature Sensor (TR- 0106) x 2 Temperature/Humidity Sensor (THA-3151) x 1 Accessories USB Communication Cable (US-15C), LAN Cable (LN-20W: For TR-701NW / 702NW only), AC Adaptor (AD-0638 or AD-0638-C), Coin Type Lithium Battery (CR-2032), Software (CD-ROM), Manual Set (Warranty Included) x 1 <Desktop Browser> Internet Explorer (6.0 or later), Firefox (15.0 or later), Chrome (22.0 or later), Safari (6.0 or later) <Mobile Browser> Safari (iOS), Chrome (iOS, Android), Firefox (Android) Supported Browsers *1: When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C 50%, 70°C 35%, and 80°C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal measurement capability. *2: The supplied lithium battery is for data backup during power failure and for emergency use only. Note that network communication cannot occur when using only the battery. *3: Battery life varies depending upon the ambient temperature and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life. Use via Network Connection The TR-700W Series Loggers allow you to make device settings, monitor current readings, gather recorded data and an array of other functions via LAN or Internet connection. The USB connection also allows for settings including wired LAN and wireless LAN settings to be made directly from a PC. Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:sales.uae@vackerglobal.com www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

  3. 14 May 2015 Various Monitoring Functions Using "WebViewer": The TR-700W Series WebViewer application enables the viewing of data graphs in your browser. In the browser you can not only view graphs and current readings, but also settings information for the target TR- 700W Series device. Using "T&D WebStorage Service": As long as you have access to the Internet, our "T&D WebStorage Service" is available; thus bringing you "anytime anywhere" access to your recorded data for monitoring, saving, analyzing, printing, and so on. This service also allows for the viewing, sharing and usage of data by multiple parties across distances at the same time, thus providing increased management efficiency. Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:sales.uae@vackerglobal.com www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

  4. 14 May 2015 Via "Current Readings Monitor": The "Current Readings Monitor" application included in the software package allows not only for the management of current readings, but also provides a way to manage all devices registered on the same network. Via Mobile Device: Both "WebViewer" and "T&D WebStorage Service" can be used with mobile devices such as smart phones and tablets, enabling easier access to data anytime, anywhere. Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:sales.uae@vackerglobal.com www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

  5. 14 May 2015 Efficient Warning Monitoring Functions It is possible to have warning report e-mails sent when user set conditions have been met. Warning report mails can be sent when an upper and/or lower limits have been exceeded, when a sensor error has occurred or when there has been a recovery from one of the set warning conditions. Also, by connecting a warning device to the external contact output terminal, it is possible to receive notification of a warning by buzzer, siren, lamp, or other electromagnetic contactor. It is also possible to select whether or not to have the external warning coupled with a warning report mail. Auto-Sending of Measurements Using Device Settings for TR-700W Series Data Logger: By making settings in the device it is possible to automatically have Recorded Data and/or Current Readings sent periodically via FTP or e-mail without the need for PC. Using the "Current Readings Monitor": If a server is not available, it is possible to use the "Current Readings Monitor" application to have recorded data automatically saved. Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:sales.uae@vackerglobal.com www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

  6. 14 May 2015 High-Performance User Friendly Graph Software Available Our newly designed software "T&D Graph" gives you greater management and analyzing power for dealing with the recorded data (TRZ format) collected from TR-700W Series loggers. "T&D Graph" allows you to read larger numbers of recorded data files (TRZ format) into the same graph, merge data, view and save data various ways. It can be downloaded free of charge at theT&D Website. This versatile graph tool not only allows the user to directly access data stored in the WebStorage Service, but the user can also specify conditions such as time period for which data to view and analyze. It is also possible to sample and filter data, add memos and write comments directly on the graph, as well as, save data to CSV Format for use with common spreadsheet software. Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:sales.uae@vackerglobal.com www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India

  7. 14 May 2015 All images and data above are copyrighted to the manufacturer T&D corporation, Japan Videos: Functioning demo : http://bit.ly/1jZAJRe Remote monitoring software demo : http://bit.ly/1srWvh8 Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55 email:sales.uae@vackerglobal.com www.vackerglobal.com Offices: UAE, USA, Kuwait, Oman & India