1 / 11

Energy Efficiency Considerations in the Design of the Southern Seawater Desalination Plant

Energy Efficiency Considerations in the Design of the Southern Seawater Desalination Plant. SSDP. Electrical Consumption. Stage 1 Energy Forecast 24.673 MW and 187.876 GWh /year. Stage 2 Energy Forecast 52.556 MW and 401.873 GWh /year. Procurement Process.

venice
Télécharger la présentation

Energy Efficiency Considerations in the Design of the Southern Seawater Desalination Plant

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Energy Efficiency Considerations in the Design of the Southern Seawater Desalination Plant

  2. SSDP

  3. Electrical Consumption • Stage 1 Energy Forecast 24.673 MW and 187.876 GWh/year. • Stage 2 Energy Forecast 52.556 MW and 401.873 GWh/year

  4. Procurement Process

  5. Key Elements for Alliance Development • Each bidder paid a sum determined by the Corporation • Facilities Engineer and Constructor selected • Basis for Design and Construct • Basis for Operations and Maintenance (25 years) • Alliance Agreement • They all stress ‘whole of life’ • Embedded staff • Engagement / Technical Presentation • Commercial negotiations • Final presentation after bids received

  6. Evaluation • Submission included • Engineering Summary Report • Draft O&M Plans • D&C Budget • 25 year O&M Budget including asset replacement. • Agreement • Technical Review • Normalisation • Most likely WOL outcome

  7. Commercial Drivers for WOL • Rigid selection process – the right partners • Competitive bid – embedded assistance • Evaluation on WOL – using Owners knowledge • Long term O&M commitment (25 years) • Risk / Reward regime in O&M – 50/50

  8. Alliance Phase • Lessons learnt from losing bid • Lessons learnt from evaluation • Embedded key staff • Design review • Procurement review • Emphasis on WOL and Sustainability

  9. Some energy outcomes • Tunnelling – optimise gravity; • RO Design – split / hybrid • Extensive use of VSD’s • Best available Energy Recovery System • Gravity Discharge of Brine • Sustainability assessment for procurement • Modified DWPS design for Stage 2

  10. Advantages of Split / Hybrid Pumping Pressures = energy

  11. Questions ? ? ?