1 / 33

Testarea instalatiilor electrice conform SR EN 61557

Testarea instalatiilor electrice conform SR EN 61557. Adrian H ĂLĂNGĂU. Siguranta ….!?. Buna functionare a instalatiilor este extrem de important a ! Problemele care apar sunt : Soc e lectric prin atingere directa Pericol de incendiu datorita suprasarcinilor Impamantare slaba

vinny
Télécharger la présentation

Testarea instalatiilor electrice conform SR EN 61557

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Testarea instalatiilor electrice conform SR EN 61557 Adrian HĂLĂNGĂU

  2. Siguranta….!? • Buna functionare a instalatiilor este extrem de importanta! Problemele care apar sunt: • Soc electric prin atingere directa • Pericol de incendiu datorita suprasarcinilor • Impamantare slaba • Modificari artizanale sau eronate ale instalatiei electrice

  3. Standarde Asigura confomitatea cu reglementarile legale Indeplinirea cerintelor Codurilorde practica IEC 60364 - standard Pan–European pentru practicile din instalatiile electrice in constructii. SR EN 61557 - Securitate electrică în reţele de distribuţie de joasă tensiune - instrumentele utilizate

  4. SR EN 61557 • Inspectia vizuala a circuitului • Rezistenta de izolatie • Impedanta buclei • 3. Rezistenta legaturii la pamant • 4. Rezistenta de dispersie a prizei de pamant • 5. Comportarea DPD-urilor • 6. Succesiunea fazelor

  5. Testarea instalatiilor • Inaintea conectarii alimentarii • Continuitatea conductorilor si inspectia vizuala • Rezistenta de izolatie • Cu alimentarea conectata • Impedanta buclei • Continuitatea legaturilor la pamant • Rezistenta de dispersie a prizelor de pamant • Testarea DPD-urilor • Succesiunea fazelor

  6. Inspectia vizuala a circuitelor • Defecte vizibile, de natura mecanica • Componentele defecte trebuie inlocuite • Realizarea celorlalte teste se va face numai dupa inlocuirea componentelor defecte

  7. Rezistenta de izolatie • Megohmmetru • Cabluri, transformatoare, motoare • Valoarea tensiunii injectate • Valoarea rezistentei de izolatie

  8. Impedanta buclei • Bucla de impamantare si a liniei • Caracterizare imediata • Bucla impamantare = priza de pamant + circuitul de impamantare • 4Ω

  9. Continuitatea legaturilor la pamant • Existenta fizica a unei cai de scurgere spre pamant a curentului care apare in cazul unui defect. • Acest lucru este asigurat de sistemul de impamantare, deci practic se verifica legatura corecta a instalatiei electrice la sistemul de impamantare.

  10. Rezistenta de dispersie a prizelor de pamant • maxim 4Ω pentru intalatiile electrice rezidentiale si industriale • maxim 1Ω pentru instalatiile aferente sistemelor de telecomunicatii

  11. Testarea DPD-urilor • DPD = DDR= RCD • Diferenta de curent > valoarea nominala => declansare • Parametri: • Prag de declansare • Timpul de declansare

  12. Testarea DPD-urilor Verificarea conexiunilor Timp declansare ms Testarea timpului de declansare Curentul de declansare mA Setarea tipului diferentialului Testarea curentului de declansare Indicatia sensului de testare

  13. Pentru acestea avem nevoie de … Testere instalatii, testere de izolatie si testere de impamantare!

  14. Tester instalatii Fluke 1653B • Rezistenta de dispersie a prizelor de pamant • Megohmetru 1000V • Impedanta buclei de pamant si impedanta liniei (trip / no trip) • PSC si PFC • Testare DPD • Succesiunea fazelor • Rezistente mici

  15. Tester instalatii Fluke 1653B • Compensarea rezistentei sondelor • Intrerupere test la detectare tensiune > 30V • Garantat la caderi de la 1m • Interfata PC • Memorie: 500 locatii • Aprobare de model

  16. Toate testerele masoara conform standardului, dar...

  17. Fara meniuri Simboluri grafice …pot fi greoaie in utilizare (daca nu le folositi zilnic)

  18. Sonda test cu buton de pornire a testului …”a treia mana” pentru realizarea masurarii

  19. Compact si usor (numai 1,2 kg) • Forma ergonomica …prea mare si prea greu

  20. Baterii normale: 6 baterii AA de 1.5Vsau 6 acumulatori AAreincarcabili de 1.2V …fara baterii speciale (scumpe, dificil de gasit)

  21. Unele masurari se fac in circuite de-energizate …iluminare afisaj

  22. Alteavantaje • USOR DE UTILIZAT! • Verificarea automata a propriei sigurante • Mod Auto la testarea DPD-urilor • Sondele de test - variate • Geanta transport dura (standard) • Robust • Rapoarte !!!

  23. FlukeView Forms • FlukeView Forms • FlukeView Forms Designer Particularizare completa!!

  24. Rapoarte • La inceputul si sfarsitul verificarii unei instalatii noi sau dupa modificarea uneia existente. • Includ: detalii despre instalatie si despre modificarile facute, ce s-a masurat si rezultatele masurarilor

  25. Testere izolatie Tensiuni pana la 10kV Curent de test: 2mA Rezistenta: 2 TΩ Descarcare automata Test strapungere Aprobare de model Interfata PC PI, DAR

  26. Testere izolatie Tensiuni pana la 1000V Curent de test: 2mA Multimetre de izolatie Aprobare de model PI, DAR

  27. Testere izolatie Pentru o testare completa si corespunzatoare: • Sistemul testat trebuie sa fie de-energizat • Selectati tensiunea de test corespunzatoare • Conectati sondele • Realizati citirea clara a rezultatului • Permiteti descarcarea tensiunii de test • Testati fiecare conductor fata de masa si fata de celelalte conductoare

  28. Bucla de impamantare • Fluke 1630 • Facilitati: • Fara deconectarea prizei de la retea si fara nici un alt tarus • Masurare curenti de scurgere • Continuitatea buclei de impamantare • Autocalibrare

  29. Rezistenta de dispersie a prizelor de pamant • Fluke 1621 • Metoda celor 3 tarusi • Masurare rezistenta, tensiune AC/DC • afisaj mare, iluminat • posibilitate setare limite • aprobare de model

  30. Fluke 1623 & 1625 • toate metodele de masura • rezistivitatea solului • masurare rezistenta • setari valori limita • AFC • IP56 • variante: BASIC, KIT • aprobare de model

  31. Testarea initiala a unui sistem Fluke 1621 Fluke 1653 Fluke 1623/1625 Proiectare sistem Fluke 1623 Fluke 1625 Instrument / aplicatie Teste repetitive Fluke 1630 Fluke 1623/25 Testarea impamantarii Fluke 1621, Fluke 1653 Fluke 1630 Fluke 1623/25

  32. Multumesc pentru atentie!

More Related