An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 29 CFR 1910.304(f)(4); or • 29 CFR 1910.304(f)(5)(v); or • 29 CFR 1910.334(a)(3)(i) • Portable electric equipment must be grounded (unless double insulated type).

  2. 29 CFR 1910.303(g)(1) & 1910.303(b)(2) – Maintain ready access to panel & repair panel door. • 29 CFR 1910.305(b)(2) – Cover open junction box. • 29 CFR 1910.157(c)(1) – Do not block fire extinguisher.

  3. 29 CFR 1910.219(d)(1) & 1910.219(e)(1) Guard belt and pulleys.

  4. 29 CFR 1910.151(c) – Provide immediate access to emergency eyewash; maybe need an emergency shower. • 29 CFR 1910.22(a)(1) – Maintain clean & orderly workspace. • More…

  5. 29 CFR 1926.1053(b)(13) – construction • 29 CFR 1910.25(d)(2)(xii) – general industry Top of stepladder must not be used as a step.

  6. 29 CFR 1910.157(c)(1) • Do not block fire extinguisher.

  7. 29 CFR 1910.23(c)(1) Open-sided floor or platform 4 feet or more above adjacent floor or ground level must have guardrail except where there is entrance to a ramp, stairway, or fixed ladder.

  8. 29 CFR 1926.405(b)(1) – construction • 29 CFR 1910.305(b)(1) – general industry Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.

  9. 29 CFR 1910.178(g)(12) Tools and other metallic objects shall be kept away from the top of uncovered batteries.

  10. General Duty Clause Employer must provide a safe surface from which to work.

  11. 29 CFR 1926.501(b)(4)(i) Each employee on walking/working surfaces shall be protected from falling through holes more than 6 feet above lower levels…

  12. 29 CFR 1910.106(e)(2)(iv) or 1910.106(e)(2)(ii) and • 29 CFR 1910.1200(f)(5) • Containers must be closed and labeled…more…

  13. 29 CFR 1910.1030(d)(4)(iii)(A)(3)(i) • Prevent protrusion of contaminated sharps.

  14. 29 CFR 1926.1052(c)(1) Stairways with four or more risers or higher than 30” must be equipped with a stair-rail system along each unprotected side or edge.

  15. 29 CFR 1910.134(h)(1)-(4) & 1910.94(a)(5)(iv) • Abrasive blasting respirator must be cleaned, stored in a clean environment, inspected, and repaired.

  16. 29 CFR 1910.305(g)(1)(iii) • Flexible cord is not to be used as a substitute for fixed wiring.

  17. 29 CFR 1910.213(h)(1) & (h)(4) • Radial arm saw needs lower guard and saw blade needs to automatically return to the starting position when released.

  18. 29 CFR 1910.23(c)(1) and 1910.178(l)(4) Employee must be provided a safe work surface with guardrails; employee needs refresher forklift training.