Isolated footing with axial load and moment. Design Input. Grade of concrete - 35 Grade of steel - 460 Allowable soil pressure – 200 KN/m 2 Column load – 1260 KN(D.L+L.L) Moment – 100 kN.m Condition about overburden of soil - No. By ACI 318. Design procedure. Checking the footing area.

Télécharger la présentation

Isolated footing with axial load and moment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Isolated footing with axial load and moment Design Input • Grade of concrete - 35 • Grade of steel - 460 • Allowable soil pressure – 200 KN/m2 • Column load – 1260 KN(D.L+L.L) • Moment – 100 kN.m • Condition about overburden of soil - No L&T-GES

  2. By ACI 318 Design procedure Checking the footing area • Arrive footing size • Total load=wt of footing+column load • Average soil pressure q= total load / footing area • Allowable soil pressure > Average soil pressure • Then footing are is ok L&T-GES

  3. Finding factored loads • Factored column load=1.4xdead load+1.7xlive load • Average factored soil pressure qnet=Factored column load/footing area • Average dv=total thick – cover - bar dia • Eccentricity e = Mu/Pu • Solving two equations to get q1 and q2 • Service load equation • Vertical equilibrium L&T-GES

  4. Check for One way shear • Take the critical section as ‘d’ distance from the • face of the column (as per ACI 318 ) • 1.find pressure at critical section • 2.find Vu • 3.find Vu • If Vu>Vu Check for Two way shear • Take the critical section as ‘d/2’ distance all around • the face of the column (as per ACI 318 ) • find pressure at critical section • Find the value of bo • 2.find Vu • 3.find Vu is smallest of these L&T-GES

  5. Safe against two way shear Otherwise increase the depth L&T-GES

  6. Check for flexural reinforcement Max moment occurs at the face of the column • Find average pressure • Find required moment Mn=Mu/ • Find required Ast • Min Ast=0.0018bh • Max spacing=18 in Development length L&T-GES

  7. Isolated footing with axial load and moment • Word document (IS Method) • Word document (ACI method) • Spread sheet (ACI method) • STAAD output (ACI method) L&T-GES

  8. Final comparison L&T-GES