  1. RHEEM COMMERCIAL WATER HEATING TRAINING

  2. TRAINING COURSE OBJECTIVES • Introduction to Rheem Commercial Booklet • Range appreciation • Familiarise key design / installation criteria • Introduction to manifolding • Introduction to sizing • Value added service

  3. Commercial Water Heating course contents • Chapter 1 - Range overview - Commercial Booklet • Chapter 2 - Heat Pump • Chapter 3 - Commercial Solar • Chapter 4 - Equaflow Manifolding • Chapter 5 - Commercial Continuous Flow • Chapter 6 - Commercial Storage Gas systems • Chapter 7 - Raypak Heating and Hot Water • Chapter 8 - Commercial Electric • Chapter 9 - Guardian Warm Water • Chapter 10 – Pump Sets • Chapter 11 - Sizing and Selecting • Chapter 12 - Commercial installation and design

  4. Chapter 1 Range Overview & Rheem Commercial Booklet

  5. Chapter 2 - Commercial Heat Pump

  6. COMMERCIAL HEAT PUMP LAYOUTS

  7. COMMERCIAL HEAT PUMP LAYOUTS

  8. Chapter 3 - Commercial Solar

  9. Commercial Solar • Terminology • Split / Pumped / Loline • Close Coupled / Thermosiphon / Hiline • Direct / Indirect (Premier Hiline)

  10. Commercial Solar Loline

  11. Commercial Solar Loline • Pumped system • Collectors and tank are split • Fluid is pumped between collectors and tanks • Can be on same level or different levels • Direct system • Consumed water passes through the collectors • Partial frost protection • In series boost

  12. Commercial Solar Loline • 325L and 410L vitreous enamel storage tanks • Manifold tanks as required • NPT200 collector • Painted aluminium selective surface • 7 riser tubes • Good performance in all regions

  13. Commercial Solar Loline • Frost • Limited frost protection • Frost sensor strategy • Electric or gas frost heater • Secondary Solar Recirculation • Maximum solar energy use • reduces energy use • BMS output • Run and fail status

  14. Commercial Solar Premier Hiline

  15. Commercial Solar Premier Hiline • Thermosiphon system • Collectors and tank are close coupled • Fluid rises through collectors naturally to tank • Tank is always above collectors • Indirect system • Transfer fluid passes through the collectors and transfers heat to tank via heat exchanger • Full frost protection • In series or in- tank electric boost

  16. Commercial Solar Premier Hiline • 300L stainless steel tank • Manifold systems as required • 8 systems per array, multiple arrays possible • S200 collector • Steel collector • Painted selective surface • Good performance in all regions

  17. Flat Plate vs Evacuated TubeCollectors

  18. Chapter 4 EQUA-FLOW MANIFOLDING

  19. EQUA-FLOW BASICS

  20. EQUA-FLOW BASICS • Header diameters for cold/hot to be equal • Branch diameters for cold/hot to be equal • Hydraulic water flow “In one side, out the opposite” • Balanced performance per unit. Full delivery capacity from system Flow direction Out In Line Flow direction In

  21. EQUA-FLOW BASICS Flow direction Out Back to Back Flow direction In

  22. EQUA-FLOW BASICS 1 1 B 0+1+1=2 A 0

  23. PATH of LEAST RESISTANCE 1 1 B A 1 1

  24. MORE EQUA-FLOW PRINCIPLES A B 1 2 1+2+2+1+0=6 1+2+1+2=6 0+2+1+1+2=6 1 2

  25. ANGLED MANIFOLD A 3 + bend 1 1 3 + bend B

  26. BACK TO BACK MANIFOLD 0.75 1 1 H4: 0.75+1+1 = 2.75 H6: 0.75+1+1 = 2.75 A B H2: 0.75+1+1 = 2.75 H5: 1+1+0.75 = 2.75 H1: 0+1+1+0.75 = 2.75 H3: 1+1+0.75 = 2.75 1 1 0.75

  27. EQUAFLOW PRINCIPLES IN PRACTICE

  28. COMPLICATED EQUAFLOW PRINCIPLES IN PRACTICE When designing/ inspecting complicated manifolds consideration must be given to primary loops as well as hot and cold headers

  29. EQUAFLOW PRINCIPLES IN PRACTICE

  30. COMPLICATED EQUAFLOW PRINCIPLES IN PRACTICE

  31. BRANCHES • NEVER use non-return valves or pressure limiting valves in the branch • These create imbalance in the branches • Non-return and pressure reducing valves must be in a train on the cold water inlet COLD WATER SUPPLY TO WATER HEATER MANIFOLD

  32. BRANCHES • Last branch should be a T piece, not an elbow, to maintain equal resistance in all branches T PIECE

  33. Chapter 5 - Commercial CFWH

  34. USE MM AND FF ADAPTERS IF HORIZONTAL LENGTH OF HORIZONTAL TERMINATING FLUE EXCEEDS 2.7M TRIM RING USE CONDENSATE DRAIN & TRAP IF VERTICAL SECTION OF HORIZONTAL TERMINATING FLUE EXCEEDS 2M RHEEM INDOOR CFWH – FLUE SYSTEMS

  35. Rheem Multipak, Tankpak, Commpak and Commpak PlusCommercial Continuous Flow Hot Water Solutions

  36. Chapter 6 - Commercial Gas Storage

  37. RHEEM Commercial Gas Storage • Work horse of the industry • 3 input sizes – 50, 110, 200MJ/hr • Indoor and outdoor models • Multi-fin flue technology • Flue damper • Hot Surface Ignition • Up to 82oC • Room sealed flue

  38. HD Gas Layout

  39. 631275 Room Sealed Flue • Converts outdoor model to indoor room sealed • Ideal where no ventilation, contaminated air supply or fluing to roof impractical • 3m and 3 x 90o bends • Re-use flue terminal • Kit P/No 299135

  40. Chapter 7 – Raypak Heating and Hot Water

  41. Raypak Layouts

  42. Chapter 8 - Commercial Electric Storage

  43. RHEEM Commercial Electric Storage • Work horse of the industry • 2 x 3 element models – 50 & 315L • 1 x 6 element model – 315L • Up to 36kW output • Indoor and outdoor installation • Heavy Duty enamel • Larger anode • Models up to 82oC

  44. HD Electric Layout

  45. Chapter 9 - Rheem Guardian Warm Water

  46. Chapter 10 - Pump Sets