1 / 5

TS-1x The Future of Monitoring.

TS-1x The Future of Monitoring. 5”. 4”. TS-1x Puck (900mhz or wifi (802.11)) 14 Channels Acceleration / Displacement. 7 Channels, BCN Connection Tachometer. 1 Channel, BNC Connection Process, Temp/Pressure/ Flow/Level. 6 Channels 24 volt DC powered

zack
Télécharger la présentation

TS-1x The Future of Monitoring.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TS-1x The Future of Monitoring. 5” 4” • TS-1x Puck • (900mhz or wifi (802.11)) • 14 Channels • Acceleration / Displacement. 7 Channels, BCN Connection • Tachometer. 1 Channel, BNC Connection • Process, Temp/Pressure/ Flow/Level. 6 Channels • 24 volt DC powered • Range, 2500 Feet, Line of Sight

  2. Ethernet Bridge • Connects directly to the Ethernet Network • Ethernet Connection • 24 vdc • POE • Up to 300 ft. from the switch • Up to 6 Zones

  3. Thermal Amplifier • Thermal Amp • Type J & K Thermocouple, RTD • 4-20 ma Input • Two Channels • Thermal Amp II • Type J & K Thermocouple, RTD • 4-20 ma Input • Six Channels

  4. Software • 1 Computer anywhere on Ethernet network • Up to 6 Zones

  5. How It Works The TS-1x connects To your asset via BNC cable Communicates data wirelessly to Uptime’s Ethernet Bridge Data appears on your office computer Updates every 30 sec to several hrs. Stores historical data according to disk space or upon fault. Uptime Pathfinder Software • Bar graphs. Grn/Yel/Red • Displays the alarm page, • The alarm limits, Overall & Banded are determined by the vibration dept. and are easily modified. • Alarm can be set to email or text • Full spectrums and waveforms are available upon each update. • Updates every 30 sec to several hours. • All information can be viewed millwide. Ethernet Bridge- Plugs into Ethernet port near asset (up to .25 miles away) • Collects data wirelessly from the TS-1x • Sends data to the computer where software resides.

More Related