1 / 1

Wake up

rEvodream Next Generation. Sure?. 2x. 1x. 6x. 3x. 4x. 2x. 5x. 6x. 4x. 3x. 2x. 1x. 5x. Quick. Quick. Quick. Quick. Quick. 0.21. 0.21. 0.95. 0.21. 0.95. 0.21. 0.21. Starting up with 2 cells selected. Wake up. ppO2 Cell 1. ppO2 Cell 2. Sleep. Sure?. Yes. Wake up!.

zev
Télécharger la présentation

Wake up

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. rEvodream Next Generation Sure? 2x 1x 6x 3x 4x 2x 5x 6x 4x 3x 2x 1x 5x Quick Quick Quick Quick Quick 0.21 0.21 0.95 0.21 0.95 0.21 0.21 Starting up with 2 cells selected Wake up ppO2 Cell 1 ppO2 Cell 2 Sleep Sure? Yes Wake up! 2x 3x 2x Starting up with 1 cell selected Calibration with O2 Calibration Too high Too high Select O2 Calibration Sure? Yes Quick Quick 2x 3x 3x 2x Voltage Cell 2 Voltage Cell 1 OK, Calibrate OK, Calibrate Calibration with Air Correct voltages for calibration: Calibration withVoltage range O2 (100%) 36 mV - 64mV Air (21%) 8.3mV - 13mV Select Air Calibration Setup Sure? Yes 2x Too low 4x Too low 4x 2x Quick Quick Change settings (*) not used in SCR mode SCR mode? Permanent backlight? Disable LEDs/HUD? Use only 1 Cell? Disable auto-off? Green zone 0.95-1.10? Select Settings (*) (*) Settings Sure? Sure? Yes No (no taps) No (no taps) No (no taps) No (no taps) No (no taps) No (no taps) 2x 5x 5x 2x Setup Select Set O2 % for calibration Set O2 % for calibration 1x 1x 1x 1x 1x 1x Sure?  Sure? Yes Yes Yes Yes Yes Yes Yes 2x 7x 7x 2x Verify settings (variables set to NO are skipped) SCR mode? Permanent backlight? (*) (*) Done Wait or 1,2,6 taps Disable LEDs/HUD? Use only 1 Cell? Disable auto-off? Green zone 0.95-1.10? Select ppO2 Display Setup ppO2 Display ppO2 Set O2 % for calibration LED Sequences Set calibration for cell 1 Keep tapping to decrease New level saved Backlight 15 sec.+ Display ppO2 cell 1 Backlight and Cell 1 Ok Quick Reference Card v3 Provided “as is” without warranty, use at your own risk. Hint: wait + 1 second after a response before tapping. 1x 1x 0.20 (*) Sleep is not possible if unit on for more than 2 minutes and ppO2>0.5 Set calibration for cell 2 Keep tapping to decrease New level saved (*) Yes Sleep Going to sleep Setup 3x 2x

More Related