1 / 10

GlueX Luminosity Limits

GlueX Collaboration Meeting, Newport News, May 8-10, 2008. GlueX Luminosity Limits. Richard Jones, University of Connecticut. Design luminosity Physics possibilities at higher luminosities Limiting factors in current design. Design Luminosity.

zia-walton
Télécharger la présentation

GlueX Luminosity Limits

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GlueX Collaboration Meeting, Newport News, May 8-10, 2008 GlueX Luminosity Limits Richard Jones, University of Connecticut • Design luminosity • Physics possibilities at higher luminosities • Limiting factors in current design

  2. Design Luminosity • Goal – produce sufficient samples of exclusive reations to be systematics-limited (maximum sensitivity to weak exotic waves) in amplitude analysis for key channels. • Translation – when that occurs depends on the final state, ie. specific backgrounds, PID demands, … • Rule of thumb: 107 events is sufficient for a decent PWA • Consider a hypothetical case: s = 50 nb BR = 30% e = 25% GlueX Collaboration Meeting, Newport News, May 8-10, 2008

  3. Design Luminosity • At Ibeam = 107g/s, it would take 57 khr (~ 20 years) to collect these statistics. • At Ibeam = 108g/s, it would take 6 khr (~ 2 years) to collect these statistics. • Result: 108g/s is sufficient to complete the hybrid spectroscopy program. But is it optimal ? g cm3 L = .071 x 30 cm x 6.0 1023x 10-33x Ibeam 1 g cm2 nb = 1.3 10-9 nb-1x Ibeam GlueX Collaboration Meeting, Newport News, May 8-10, 2008

  4. Design Luminosity • Define: tagger figure of merit • Factor that rescales the amount of run time needed to reach a given level of statistical error in a tagged histogram. • Reference for FOM shown is the GlueX tagged beam under nominal conditions at 9 GeV, but with no mistags. • Assumes detector identifies correct beam bucket 100% of the time. • Shows some gains up to 3 108 Hz. • Gains are only about 25% for factor 3 in backgrounds. GlueX Collaboration Meeting, Newport News, May 8-10, 2008

  5. Design Luminosity • For 25% more statistics, what do we lose? • x3 radiation damage in FCal • x3 accidentals in the TOF and Start • x3 pileup in the FDC, extra tracks, etc. • x3 in channel count in the microscope – $$$ • x3 in radiator thickness – reduced polarization GlueX Collaboration Meeting, Newport News, May 8-10, 2008

  6. Design Luminosity • If this argument was not made before, what was the basis of the design goal of 108g/s? • the intuitive criterion of 50% accidental tags • evidence from Monte Carlo simulation that detector backgrounds are going to preclude higher luminosities • FCal radiation damage – already an issue at 108 • TOF occupancy – within a factor of 3-5 of ceiling • FDC pileup and extra tracks – within factor of 3-5 GlueX Collaboration Meeting, Newport News, May 8-10, 2008

  7. Physics at Higher Luminosity • What physics might make this interesting? • inverse DVCS – looks feasible • threshold J/Y – statistically difficult • Cascade baryons – needs kaon PID GlueX Collaboration Meeting, Newport News, May 8-10, 2008

  8. Beam Limiting Factors • Tagging near the end-point • no polarization • no significant collimation • amorphous radiator – factor 100 more luminosity available (if untagged) • current tagger design has full coverage over 9-11.4 GeV, designed to run up to 50 MHz / GeV. • at 50 MHz / GeV in end-point region, detector backgrounds are comparable to nominal conditions with polarized beam at 108g/s. GlueX Collaboration Meeting, Newport News, May 8-10, 2008

  9. Detector Limiting Factors • FCal radiation damage • Inner blocks could be shielded, giving up low-angle g acceptance, ok for some physics. • FTOF occupancy • ditto. • FDC pile-up – will be ultimate limiting factor. • essential for just about any physics • no effective means to shield them GlueX Collaboration Meeting, Newport News, May 8-10, 2008

  10. Conclusions • Design luminosity is optimized for carrying out the hybrid spectroscopy program. • Nominal high-intensity running conditions are consistent with tagging at 50 MHz / GeV at the end-point. • The photon source will produce as much intensity as the experiment can handle in any scenario. • With a dedicated end-point tagger, one can tag effectively up to 250 MHz, provided the detector can trigger. • With 250 MHz on 11 < Eg < 12 GeV, detector background would be x5 nominal, probably an upper limit. • FDC pile-up will be the limiting factor – how to estimate it? GlueX Collaboration Meeting, Newport News, May 8-10, 2008

More Related