1 / 43

GeneralMeasure_Weighing Indicator

General Measure compact designed weighing transmitters fit your business better.

Télécharger la présentation

GeneralMeasure_Weighing Indicator

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 、Profinet、Ethernet IP

  2. GMT-X1 WEIGHING TRANSMITTER

  3. GMT-X1 Weighting Transmitter GMT-X1, a DIN rail mounted weighing transmitter for industrial automation, can be used in various system weighing applications, such as weight checking, loss- in-weight, liquid filling, batching, vessel and silo weighing, etc. Programmable I/O Various Configurations Bluetooth Communication Remote Setting Weasy Support Tool Mobile App: connect with app through Bluetooth for setting the parameters and monitor indicator status; Programmable I/O by PLC. Software Highlight Calibration without weights (by loadcell sensitivity value ); Printer function; Self-testing for I/O and Communication port; Self-editable boot screen. Hardware Highlight Stainless steel case with compact design; Different configuration choice, a variety of combination; Bluetooth communication; Standard: RS485 + RS485/RS232(Selectable). Hardware Option1: 3 Input 5 Output or 3 Input 4 Output (relay) Hardware Option2: RS485+16bit Analog or 2 Input 4 Output Hardware Option3: Modbus TCP or Ethernet/IP or Profinet (Hardware Option1,2,3 can be selected at the same time) ANALOG OUTPUT RS485/RS232

  4. GMT-H1 Weighing Transmitter PRODUCT INTRO GMT-H1 weighing transmitter is designed for industrial weighing application. It's harsh mount, IP65 protection widely used in silo and vessel application. FEATURES Anti-dust and waterproof harsh mount case; 6-wire loadcell interfaces, connecting up to 8 loadcell in 350Ω; Support theoretical data calibration; Support GPRS, Modbus-RTU, Modbus-TCP/IP, RS485 for communication; The function of automatic upload relevant weighing data; Through IO port to get the information of material level. RTU DIMENSION Unit:mm

  5. SPECIFICATION Model GMT-H1 Power AC 90-260V 50Hz(or 60Hz) ±2% -20~60℃;90%R.H Without dew 10W Temperature General Specification Power consumption Weights 750g A/D conversion 24bit Delta-Sigma Sampling rate Sampling rate, initial value:100times/sec, range: 50,60,100,120,200,240,400,480 times/sec Nonlinearity 0.01%F.S 10PPM/℃ 0.1μV/d / 0.5μV/d Gain drift Measurement Paramenters Sensitivity Input range MAX 0.02~15mV Maximum display accurarcy 1/100,000 1 simulated weighing platform load cell interface can connect up to 8 load cell that is in 350Ω,and the sensitivity in 1mV/V、 2mV/V、 3mV/V. 5V 200mA(Max) Weighing platform load cell Load cell excitation RS485(Standard); Support ModbusRTU, continuous transmission protocol RJ 45(Standard); Support Modbus-TCP, continuous transmission protocol I/O Interfaces and Communications GPRS data transmission function Fixed IO: 3 Input, 3 Output Optional IO: 3 more(can be selfdefined as output or input) APPLICATION The high-speed transmission Room2208, Block A, Building 6, Shenzhen International Innovation Valley,Nanshan District, Shenzhen, Guangdong Province, P.R.China.

  6. GM9907 Series Touch Screen Weighing Controller

  7. Making the World Measurable Linking Your Smart Life It can be widely used in food, feed, seed, fertilizer, powder and other industries.

  8. User-friendly Design, Easy Operation With Hopper Ton Scale Technician Operator 2020/4/16 13:58 2020/4/16 13:58 1 0.00g 0pcs 1 0.00g 0pcs 50.00 0.00g 0.00g • 7-inch Touch screen for displaying clearly and operating easily, Single/double scale interface mode switching; • Different types of Home Screen for Different Application; A B 50.00 50.00 kg kg t Run Run Run ScaleFi-FillZEROManual HoldderHanging Lift Bag Lock Bag Pause Lock Screen > > > Bacth Set: 0 Bacth Left: 0 1 75.00 1 0.00 4 0.00 4 0.00 Target 0.0t Co-Fi Remain User ACUM: 80.0t 2 0.00 5 0.00 2 0.00 5 0.00 More More 0.0t Me-Fi Remain 0pcs > > > 0.00kg 6 0.00 6 0.00 3 0.00 3 0.00 0.0t Free Fall Recipe Details > Start Start Peripherals Peripherals Menu E-Stop Menu Recipe E-Stop Recipe Statistic Filling Test Statistic Filling Test • All Parameter Matched and Displayed according to the Scale; • Modular design, guided step-by-step operation, one key switch; • Screen Saver Displaying after the Set Time,Dynamic display of operating status and data; 0.20 Run 2021/01/06 14:00 t Recipe Operator Filling Values Process Parameter Run 0.20 t Technician Menu 0.20 0.20 停止 Run 2021/01/06 14:00 t t 超级管理员 Operator 配方参数 Recipe Target 10.00 零区 I/O Function Weight Zero Rang.Filter... Running Calibration Ton Scale Prarmeter 0.5 s 吊袋延时 支架控制模式 自动上升/下降 I/O Function Select... Unit,Scale... 定量参数 Filling Values 吹气方式 5.0 s 支架上行时间 上行延时前开始吹气 81.20 Motor COM Master Write Data To Other... 0.5 s 5.0 s 支架下行时间 Time&Language 吹气时间 Remain PCS Frequaecy,Gate Open Steps... Time,Language... t 回气阀关闭方式 E-Stop Start 加料后关闭 Peripherals Home Recipe Statistic Filling Test Process 0 过程参数 Parameter 0.5 s 吊袋复位时间 0.00 Ton Scale Tatal ACUM PCS 吨包参数 Prarmeter HMI Ver.010102 Complie Time 2020/12/22 09:30:25 0 脱钩上行功能 脱钩上行功能 开始 调试 外设 急停 E-Stop 主界面 Home 配方 统计 Start Peripherals Home E-Stop Recipe Statistic Filling Test Start Peripherals Recipe Statistic Filling Test Intelligent Function Design, Smart Operation • USB for importing and exporting data, upgrading software and customizing boot screen, etc. • Self-adaptive Function,Support a variety of scale structure mode; Statistic 35.00 g Running Statistic 0.98 Run 0.98 2021/01/06 14:00 Run 2021/01/06 14:00 kg kg Technician Recipe Esc Esc Admin Admin 0.0 s Filling PreDelay Timer 0 0.01 kg Fill PreZero Interval Weight 5 pcs Target Total ACUM Time SN Recipe ACUM Recipe ACUM 1-8 Fiiling Values 0.0 s Result Check Mode Result Waiting Timer Wait Stable Recipe ID Print Recipe ACUM 1 ACUM pcs ACUM Weight kg 75.00 86.61 2021-02-22 11:07:27 0.5 s 支架下行时间 吹气时间 Adaptive 10000000.00 20 01 2 2021-02-22 11:07:16 75.00 76.09 History Data Edit 9-16 User ACUM 回气阀关闭方式 User ACUM 加料后关闭 50000000.00 5 02 2021-02-22 11:07:10 3 Print Select Recipe ACUM Data Print Total ACUM Process Paramet 5 Adaptive Level 0.5 s Permanent Replace 吊袋复位时间 Adaptive Switch 3-Speed Fill 40 03 0.00 4 17-20 Clear History Data Info USB Data Export Print All Recipe ACUM Print Recipe ACUM 0.05 0 04 5 History Data History Data Adaptive Hopper Scale Parameter Adaptive 3-Speed Fill 0.00 0 05 6 Clear All Recipe ACUM Jog Flow ON/OFF Over/Under Check 50 06 50000000.05 Print Data Management 开始 Start 开始 Start Start Peripherals Home E-Stop Recipe Statistic Filling Test Peripherals Home E-Stop Recipe Statistic Filling Test Peripherals Home E-Stop Recipe Statistic Filling Test • Host Mode: Can be Used as Industrial Control Panel to Configure PLC or Transducer.

  9. GM9907-L2/LD Packing Controller (L2:Single Hopper; LD:Double Hopper) GM9907-L2/LD is the single/double hopper packing controller, widely used for, granule packing scale, powder packing scale,big bag,valve type scale-cement, etc. Version Features Ton Scale With Hopper Operator Technician 2020/4/16 13:58 2020/4/16 13:58 User-Friendly · Better Experience 1 0.00g 0pcs 50.00 1 0.00g 0pcs 0.00g 0.00g A B 50.00 50.00 • Memory card build in, 7-inch Touch screen for displaying clearly and operating easily, Single/double scale interface mode switching; kg kg t Run Run Run ScaleFi-FillZEROManual HoldderHanging Lift Bag Lock Bag Pause Lock Screen > > > Bacth Set: 0 Bacth Left: 0 1 0.00 1 75.00 4 0.00 4 0.00 Target 0.0t Co-Fi Remain User ACUM: 80.0t 2 0.00 5 0.00 2 0.00 5 0.00 More More 0.0t Me-Fi Remain 0pcs > > > 0.00kg 6 0.00 6 0.00 3 0.00 3 0.00 0.0t Free Fall Recipe Details > Start Start Peripherals Menu Peripherals E-Stop Menu Recipe E-Stop Recipe Statistic Filling Test Statistic Filling Test • Self-Adaptive: I/O Programmable; • L2: single hopper; LD: single or double hopper, can be choosed, interface displayed accordingly; • Multi-Mode: With Hopper, No Hopper, Big Bag Scale,Valve Scale,PLC; User Logic(1) Scale Structure Run 0.20 t Technician Menu OFF To On Edge Trigger OFF To On Edge Trigger Scale Structure Manual Unlock Bag With Hopper User Logic Type User Logic Type DISC Gate Pos Detect Single Scale Working Mode Recipe ACUM Logic Trigger Type Logic Trigger Type I/O Function Input-1 By Trigger Function Weight Zero Rang.Filter... Calibration I/O Function Select... Unit,Scale... 触发输入断口 Filling 无定义 Scale Structure None Trigger Fune(IN) 输出信号端口 Fill Ga 无定义 Motor COM Master Write Data To Other... Trigger Func(OUT) Trigger Fune(OUT) None None Time&Language Big Bag Scale No Hopper With Hooper Frequaecy,Gate Open Steps... Time,Language... 延时接通端口 User ACUM Clamp Delay ON Timer Delay ON Timer 0.0s 0.0s PLC Valve Scale 0.0s Logic Output On Timer 0.0s Logic Output On Timer History Data HMI Ver.010102 Complie Time 2020/12/22 09:30:25 Start Peripherals Home E-Stop Recipe Statistic Filling Test Communication USB RS485+RS232 12 Input/16 Output • For staring, stopping, feeding, unloading, clamping/loosening bags,etc; • For connecting PC,PLC,Printer,Label Printer, Romote Display,Code Printer,or other external devices,for reading and setup remotely; • For importing and exporting recipes,works,I/O function communication and other parameters, upgrading system software,customizing boot screen,etc; Modbus TCP • For connecting PC, PLC, Printers,etc., for reading remotely.

  10. Specification Model GM9907-L2/LD Power Supply DC24V Operating Temperature -10~40℃ General Specification Maximum Humidity 90%R.H without dew Test Standard Class III 6000e,1μV/d Power Consume A/D converter type A/D Conversion Rate Non-Linear About 15W 24 bit Sigma-Delta 120/240/480/960 times /per second 0.01%F.S Gain Drifting 10PPM/℃ Minimum Sensitivity 0.02μV/d Measurement parameters Analog Input Range 0.02~15mV Display Accuracy 1/100,000 Power Source for Load Cell Input Resistance Zero Point Adjustment Range 12 Input 16 Output, I/O Selectable 12 Input, Active-low Start, Emergency stop, Stop, Zeroing, Clear alarm, Clear total ACUM, Bag Lock/Unlock, Manual discharge, Manual fine flow, Manual coarse flow, Change recipe, Empty material 16 Output, Single drive current 500mA Run, Stopped, Coarse flow, Medium flow, Fine flow, Bag lock, Result waiting, Ready, Discharge, -NZ-, Pat bag, FILL, EMPT, Alarm, Batch complete, Over/Under DC5V 125mA(MAX) 10MΩ 0.002~15mV(load cell 3mV/V ) I/O Interfaces and Communications 113±1mm 124±0.2mm 179±1mm 41±0.2mm Installation dimensions 48±0.2mm 190±0.2mm Application Schematic Diagram Start StopClip/Loose bag StartStopClip/Loose bag StartStopClip/Loose bag StartStopClip/Loose bag A B Add Add Add Add Add Add Add A B A B A B Discharge Discharge Discharge Discharge Discharge Discharge Discharge Punching bag Punching bag Clip bag Clip bag Clip bag Punching bag Punching bag Punching bag conveyor Single Channel Packaging Controller with Hopper Double Channel Packaging Controller without Hopper Double Channel Packaging Controller with Hopper Double Channel Packaging Controller without Hopper GM9907-L2 GM9907-LD

  11. GM9907-L4 Reduce weight method packing controller GM9907-L4 is designed for Loss-in-weight bagging machine. It can be widely used in rice, grains, feeds, chemical industry, etc. Version Features Admin Descease Scale 2020/4/16 13:58 Recipe 50.00 kg Run 2021/01/06 14:00 Recipe ID 01 Target: 0g 0pcs User-Friendly · Better Experience 0g Esc Admin 50.00 75.00 kg Target 02号 02 01 Filling Values 0.00 0.00 0.00 • Memory card build in, 7-inch Touch screen for displaying clearly and operating easily; 50.00 kg Co-F FILL Co-Fill Remains kg 04 03 Me-F FULL 20.00 kg Me-Fill Remains 0.00 0.00 Fi-F Not Emptty Filling Timers 1.00 kg Total Supply Weight:50.00 HOLD 05 06 Free Fall 0.00 0.00 0.00 kg Co-Fill Me-Fill Fi-Fill Clear Alarm Bag Lock ZERO Lock Screen Over Value Over/Under FreeFall Correction 08 07 > > Batch: Batch Remain: 5pcs 3pcs 0.00 kg 0.00 1 75.00 0.00 Under Value > > User ACUM: Total ACUM: 09 10 More ... 2 0.00 Patting Para/ Overtime Monitor 0pcs 7pcs 178.84 kg 0.00 9.00 > 178.84 kg 3 0.00 Start Peripherals Menu E-Stop Recipe Statistic Filling Test Start Peripherals Menu E-Stop Recipe Statistic Filling Test • Starting Patting mode when filling material to shape bags by setting relevant parameter; • Data backup and recovery function can save the optimal parameters and improve the working efficiency; • It can store 20 groups of recipes, 9 groups of users accumulation data; System Info 0.20 Recipe Run 2021/01/06 14:00 Statistic 0.98 50.00 kg Run Run 2021/01/06 14:00 2021/01/06 14:00 t kg Esc Esc Admin Admin Esc Admin Communication All Reset Reset 0.01 kg 5 pcs Total ACUM 02号 02 Patting Para. 01 Overtime Monitor Recipe ACUM 1-8 0.00 0.00 0.00 Filling Values Version Reset Basic Para. Reset All(No Calibration) Recipe ID No-Patting 5 s Supply Overtime ACUM pcs ACUM Weight kg Patting Mode 04 03 Patting Mode Advanced Para. Reset Recipe Reset 10000000.00 20 01 0.00 0.00 Filling Timer 9-16 User ACUM Reset Calibration I/O Function Reset 50000000.00 5 02 05 06 Reset 0.00 0.00 When Filling No-Patting 40 03 Over/Under FreeFall Correction 0.00 08 07 17-20 0.00 0.00 0.05 0 04 History Data 09 10 Parameter Backup 0.00 Backuo 0 05 Backup Date: 2021/01/06 13:00:00 Patting Para/ Overtime Monitor Others Clear All Recipe ACUM 0.00 9.00 Recovery From Backuo Reset Delete 50 Delete Backup 06 50000000.05 Print 开始 Start Start Peripherals Home E-Stop Recipe Peripherals Statistic Filling Test Home E-Stop Recipe Statistic Filling Test Start Peripherals Home E-Stop Recipe Statistic Filling Test Communication USB RS485+RS232 12 Input/16 Output • For staring, stopping, feeding, unloading, clamping/loosening bags,etc; • For connecting PC,PLC,Printer,Label Printer, Romote Display,Code Printer,or other external devices,for reading and setup remotely; • For importing and exporting recipes,works,I/O function communication and other parameters, upgrading system software,customizing boot screen,etc; Modbus TCP • For connecting PC, PLC, Printers,etc., for reading remotely.

  12. Specification Model GM9907-L4 Power Supply DC24V Operating Temperature -10~40℃ General Specification Maximum Humidity 90%R.H without dew Test Standard Class III 6000e,1μV/d Power Consume A/D converter type A/D Conversion Rate Non-Linear About 15W 24 bit Sigma-Delta 120/240/480/960 times /per second 0.01%F.S Gain Drifting 10PPM/℃ Minimum Sensitivity 0.02μV/d Measurement parameters Analog Input Range 0.02~15mV Display Accuracy 1/100,000 Power Source for Load Cell Input Resistance Zero Point Adjustment Range DC5V 125mA(MAX) 10MΩ 0.002~15mV(load cell 3mV/V ) 2 Input 16 Output, I/O Selectable 12 Input, Active-low I/O Interfaces and Communications Start, Emergency stop, Stop, Zeroing, Clear alarm, Change recipe, Bag Lock/Unlock, Manual discharge, Manual fine flow, Manual coarse flow, Clear total ACUM, etc. 16 Output, Single drive current 500mA Run, Stopped, Coarse flow, Medium flow, Fine flow, Bag lock, Result waiting, Pat bag, FILL, Batch complete, Supply full, Pause, etc. 113±1mm 124±0.2mm 179±1mm 41±0.2mm Installation dimensions 48±0.2mm 190±0.2mm Application Schematic Diagram Start Stop Clip/Loose bag Fill Add Clip bag Punching bag Reduce weight method packing

  13. GM9907-L5 Bulk Scale Controller GM9907-L5 is designed for bulk scale to solve the problem of batch weight and automatic totalizing of incoming and outgoing material. It can be used widely used in chemical, grain, feeds, construction and harbor logistics industry, etc. Version Features Bulk Scale: Stock-In User-1-Administrator 2020/4/16 13:58 Recipe 50.00 kg Run 2021/01/06 14:00 Recipe Recipe 1 Target: 0.00kg 0pcs 0.00kg 50.00 0.00 t/h User-Friendly · Better Experience Esc Admin 75.00 kg Target 02号 02 01 Filling Values 0.00 0.00 0.00 • Memory card build in, 7-inch Touch screen for displaying clearly and operating easily; 50.00 kg Co-Fill Remains kg 04 03 20.00 kg Me-Fill Remains 0.00 0.00 Filling Timers RUN Co-F Fi-F HOLD DISC -NZ- 1.00 kg 05 06 Free Fall 0.00 0.00 Co-Fill Fi-Fill DISC EmptyBin ZERO ClearAlarm Lock Screen 0.00 kg Over Value Over/Under FreeFall Correction 08 07 Target FlowrateStock-Out Total > > > Stock-In ACUMTotal ACUM > 0.00 kg 0.00 0.00 Under Value 0pcs 0g 09 10 0pcs 0g Patting Para/ Overtime Monitor 0.00 9.00 0g/h 0g Start Peripherals Menu E-Stop Recipe Statistic Filling Test Start Peripherals Menu E-Stop Recipe Statistic Filling Test • Flow rate function can discharge material automatically and alarm when flow rate is low,which is more intelligent; • Two packing mode: Motor or Pneumatic; Add/Discharge feed is more convenient; • Two scale mode: Stock-In or Stock-Out; Data information is more convenient to operate; Motor 50.00 kg Run 0.98 Run 2021/01/06 14:00 2021/01/06 14:00 ACUM Info&Scale Mode 50.00 kg Recipe Run 2021/01/06 14:00 kg Back Back Admin Admin Back Admin 5 pcs Filling DISC Stock-In Scale Mode Permanent ACUM Target Flowrate On/OFF 02号 02号 01 Filling Values Recipe ACUM 0.00 0.00 0.00 20.00 t/h 0.00 kg 0.00 kg DISC Gate Driver Normal Motor(One Pos.) Fill Gate Driver Motor Drived Target Flowrate Stock-Out Total 04 03 Filling Timers Scale Mode 0 Filler Motor Cfg ID DISC Gate Pos.Signal Flowrate Low Alarm On/OFF ON:If Closed 0.00 0.00 User ACUM Over/ Under 3 PCS 0.8s Flowrate Low Alarm Trigger Count 05 06 Co-Fill Gate Open Time DISC Gate Pos.Detect when Filling 0.00 0.00 3.0s DISC Gate Close OverTime Stock-Out 0.2s Stock-In Flowrate Low Auto Adjust On/OFF Fi-Fill Gate Open Time Floerate/ Function 08 07 Scale Mode 0.00 0.00 1.0s 4.0s DISC Gate Open Timer Filler Gate Close OverTime 09 10 Filler Gate Pos. Signal ON:If Closed Motor Group ID 0.00 9.00 History Data Start Start Peripherals Menu E-Stop Recipe Peripherals Home E-Stop Statistic Filling Test Recipe Statistic Filling Test Start Peripherals Home E-Stop Recipe Statistic Filling Test Communication USB RS485+RS232 12 Input/16 Output • For staring, stopping, feeding, unloading, clamping/loosening bags,etc; • For connecting PC,PLC,Printer,Label Printer, Romote Display,Code Printer,or other external devices,for reading and setup remotely; • For importing and exporting recipes,works,I/O function communication and other parameters, upgrading system software,customizing boot screen,etc; Modbus TCP • For connecting PC, PLC, Printers, etc., for reading remotely.

  14. Specification Model GM9907-L5 Power Supply DC24V Operating Temperature -10~40℃ General Specification Maximum Humidity 90%R.H without dew Test Standard Class III 6000e,1μV/d Power Consume A/D converter type A/D Conversion Rate Non-Linear About 15W 24 bit Sigma-Delta 120/240/480/960 times /per second 0.01%F.S Gain Drifting 10PPM/℃ Minimum Sensitivity Measurement parameters 0.02μV/d Analog Input Range 0.02~15mV Display Accuracy 1/100,000 Power Source for Load Cell Input Resistance Zero Point Adjustment Range DC5V 125mA(MAX) 10MΩ 0.002~15mV(load cell 3mV/V ) 12 Input 16 Output, I/O Selectable 12 Input, Active-low Start, Emergency stop, Stop, Zeroing, Clear alarm, Fill permission, Clogged, Manual fine flow, etc. 16 Output, Single drive current 500mA I/O Interfaces and Communications Run, Stopped, Clogged, Coarse flow, Fine flow, Result waiting, Over/under, Alarm, Stock-out Done, Last feed, DISC, -NZ-, etc. 113±1mm 124±0.2mm 179±1mm 41±0.2mm Installation dimensions 48±0.2mm 190±0.2mm Application Schematic Diagram Start Stop Add Discharge Bulk Weight Packing

  15. GM9907-LB Batching Scale Controller GM9907-LB is designed for batching scale that can sort feeding orders of a variety of materials. It can be widely used in concrete mixing, bituminous mixing, metallurgy, chemical, feeds industry, etc. Version Features 2020/4/16 13:58 2020/4/16 13:58 Batching Controller Batching Controller Administrator Administrator Running Running User-Friendly · Better Experience • Memory card build in, Dynamic batching process can be graphically displayed for better understanding and monitoring;. 04 04 Recipe: Recipe: 10.31 10.31 517 pcs 517 pcs 20 20 Total ACUM: Total ACUM: Batch Cfg: Batch Cfg: 2600.021 kg 2600.021 kg kg kg 20 20 Batch Left: Batch Left: 0.00 50.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 #1 #2 #3 #4 #5 #6 #1 #2 #3 #4 #8 #5 #9 #11 #12 #7 #6 #10 Supplenment 2 Percentage Supplenment Percentage 10.31 kg TARE TARE Clear Tare Clear Tare 10.31 kg 70% 70% Manual DISC Manual DISC Manual Stir Manual Stir DISC DISC Co-F Co-F Stir Stir 50% 50% Start Start Recipe Recipe ZERO Pause ZERO Pause EmptyBin EmptyBin Menu Menu Statistic Statistic • Support the batching of 12 kinds of materials. It can be customized according to the batching process sequence, which is flexible to use; • The working process is clear. Feeding value and time of the material can be set, and real-time feeding dynamic can be displayed; • User-friendly design: Save function when power down and monitoring alarm function; Recipe Recipe False alarm 9 0.5s 1 Recipe Name: Corifig Mumbers Of Supplenment: No definition Recipe:1 Supplement:2 Filling PreDelay Timer Reset Order 0.5s 50.00kg COMP.Inhibit Timer(Co-F) Target Batching Process Order Defined By Following Sequence: Ingredients timeout 0.5s 10.00kg COMP.Inhibit Timer(Me-F) Co-Fill Ramin Silo 2 Silo 6 Silo 1 Silo 5 Silo 3 Silo 4 Useing recovery 0.5s 3.00kg Me-Fill Ramin COMP.Inhibit Timer(Fi-F) 确定 0.80kg 0.5s Free Fall Stir Control 0.05kg Over Limit Value Silo 7 Silo 11 Useing recovery? Silo 10 Silo 8 Silo 9 Silo 12 0.05kg Under Limit Value Fill Pause Control NO YES More 100s Near Zero Band 9999,99 kg Power Loss Resume Result Waiting Timer Communication USB RS485+RS232 12 Input/16 Output • For staring, stopping, feeding, unloading, clamping/loosening bags,etc; • For connecting PC,PLC,Printer,Label Printer, Romote Display,Code Printer,or other external devices,for reading and setup remotely; • For importing and exporting recipes,works,I/O function communication and other parameters, upgrading system software,customizing boot screen,etc; Modbus TCP • For connecting PC, PLC, Printers,etc., for reading remotely.

  16. Specification Model GM9907-LB Power Supply DC24V Operating Temperature -10~40℃ General Specification Maximum Humidity 90%R.H without dew Test Standard Class III 6000e,1μV/d Power Consume A/D converter type A/D Conversion Rate Non-Linear About 15W 24 bit Sigma-Delta 120/240/480/960 times /per second 0.01%F.S Gain Drifting 10PPM/℃ Minimum Sensitivity 0.02μV/d Measurement parameters Analog Input Range 0.02~15mV Display Accuracy 1/100,000 Power Source for Load Cell Input Resistance Zero Point Adjustment Range DC5V 125mA(MAX) 10MΩ 0.002~15mV(load cell 3mV/V ) 12 Input 16 Output, I/O Selectable 12 Input, Active-low Start, Emergency stop, Stop, Pause, ZERO, Clear alarm, Change recipe, M-DISC permission, TARE, Clear tare, Manual stir, etc. 16 Output, Single drive current 500mA Run, Stopped, Coarse flow, Medium flow, Fine flow, Result waiting, Over/under, DISC, -NZ-, Alarm, Stir, etc. I/O Interfaces and Communications 113±1mm 124±0.2mm 179±1mm 41±0.2mm Installation dimensions 48±0.2mm 190±0.2mm Application Schematic Diagram Industrial control host Discharge Add 1# 2# 3# 4# 5# 6# 7# 8# 9# 10# 11# 12# Batching, up to 12 materials