1 / 11

First Operation of MI8 Collimation

First Operation of MI8 Collimation. Bruce C. Brown All Experimenters Meeting 22 January 2007. MI8 Collimation. Loss Control for Main Injector High Intensity Operation – Demand goes UP Run II began with one Booster Batch Operation ~ 4.5 E 12 p NuMI operation added 5 Booster Batches

Télécharger la présentation

First Operation of MI8 Collimation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. First Operation of MI8 Collimation Bruce C. Brown All Experimenters Meeting 22 January 2007

  2. MI8 Collimation Loss Control for Main Injector High Intensity Operation – Demand goes UP • Run II began with one Booster Batch Operation ~ 4.5 E 12 p • NuMI operation added 5 Booster Batches • Run II slip-stacking added another Batch with higher losses • Operation for Run II & NuMi with slip-stacking uses 11 Batches Losses and Residual Radiation • Residual Radiation Survey beginning in June 2004 showed many loss points – especially surprising at Defocusing Quads • Slip-stacking and NuMI operation have raised the average • Careful tuning has kept down the rate of rise. • New Loss Monitor Electronics allow better studies AEM - Bruce C. Brown, Fermilab - Main Injector

  3. MI8 Collimation Collimation Efforts: MI8 – Collimate halo on top-bottom-left-right, two locations (90o advance) with fixed-aperture collimators (2” x 2”) Installed in 2006 Facility Shutdown MI – Collimate slip-stacking losses with a primary (thin) and 4 secondary collimators (fixed aperture) positioned in MI300 Region. For Installation in 2007 AEM - Bruce C. Brown, Fermilab - Main Injector

  4. MI8 Collimation Devices for MI836 and MI838 • Two Collimators with motion systems plus Marble Mask • Vertical and Horizontal BPM’s • Loss Monitor (upstream of Mask, on Wall) AEM - Bruce C. Brown, Fermilab - Main Injector

  5. MI8 Collimation AEM - Bruce C. Brown, Fermilab - Main Injector

  6. MI8 Collimation AEM - Bruce C. Brown, Fermilab - Main Injector

  7. MI8 Collimation Implementation Plan: • Study Collimator Losses vs. Position (LM at 836, 838) • Choose position for each edge • Horizontal and vertical - 4 devices • Measure Effect in MI • Vertical Aperture at Q301 • Loss pattern following injection AEM - Bruce C. Brown, Fermilab - Main Injector

  8. MI8 Collimation Scans of Transmission and Loss Axis: Collimator Position -- 838BV (left) – 836AH (right) Yellow: Transmission (I:TOR806/I:TOR852) Green: Marble Mask Loss Monitor (LM8C1 or LM8C3) Red: Wall-mounted Loss Monitor (LM8C2 or LM8C4) AEM - Bruce C. Brown, Fermilab - Main Injector

  9. MI8 Collimation With Collimation: 6 mm loss free Without Collimation: 2 mm loss free Vertical Aperture Scan at Q301 Scan vs. I:V231 Trim Current Yellow is LM301, Red is VP301 AEM - Bruce C. Brown, Fermilab - Main Injector

  10. MI8 Collimation MI Loss Monitors around ring sampled during 40 ms near injection Black No Collimation Red Horizontal Coll Blue Hor & Ver Coll Big Losses at Lambertson Locations Inj, RR Transfer, Abort, MI52, MI60, MI62 AEM - Bruce C. Brown, Fermilab - Main Injector

  11. MI8 Collimation Next Steps: • Scrape with modest collimation (1/8% per jaw) [Study was with ½% loss per jaw – 3.5% observed] This began on Jan 18. • Study loss effects • Notice operational issues (trip from tune-up beam…) • Scrape more halo as we gain experience MI300 Collimation System: • Install during 2007 Shutdown AEM - Bruce C. Brown, Fermilab - Main Injector

More Related