1 / 9

Prototype Multi-Energy Soft X-ray Diagnostic for EAST

Supported by. NSTX-U. Prototype Multi-Energy Soft X-ray Diagnostic for EAST. Kevin Tritz Johns Hopkins University. Coll of Wm & Mary Columbia U CompX General Atomics FIU INL Johns Hopkins U LANL LLNL Lodestar MIT Lehigh U Nova Photonics ORNL PPPL Princeton U Purdue U SNL

Télécharger la présentation

Prototype Multi-Energy Soft X-ray Diagnostic for EAST

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Supported by NSTX-U Prototype Multi-Energy Soft X-ray Diagnostic for EAST Kevin Tritz Johns Hopkins University Coll of Wm & Mary Columbia U CompX General Atomics FIU INL Johns Hopkins U LANL LLNL Lodestar MIT Lehigh U Nova Photonics ORNL PPPL Princeton U Purdue U SNL Think Tank, Inc. UC Davis UC Irvine UCLA UCSD U Colorado U Illinois U Maryland U Rochester U Tennessee U Tulsa U Washington U Wisconsin X Science LLC Culham Sci Ctr York U Chubu U Fukui U Hiroshima U Hyogo U Kyoto U Kyushu U Kyushu Tokai U NIFS Niigata U U Tokyo JAEA Inst for Nucl Res, Kiev Ioffe Inst TRINITI Chonbuk Natl U NFRI KAIST POSTECH Seoul Natl U ASIPP CIEMAT FOM Inst DIFFER ENEA, Frascati CEA, Cadarache IPP, Jülich IPP, Garching ASCR, Czech Rep NSTX-U Monday Physics Meeting PPPL, Princeton, NJ June 25th, 2012

  2. ME-SXR fast Te technique used to reconstruct RF heated Te profile between MPTS measurements L. Delgado-Aparicio, et al., JAP 102, 073304 (2007). L. Delgado-Aparicio, et al., PPCF 49, 1245 (2007). • • Reconstructed Te shows peak >4keV ~15% higher than MPTS measurement • MPTS profiles used to cross-check ME-SXR reconstruction, provide normalization

  3. Original diode-based ME-SXR system operated on NSTX during 2010 run Edge ME-SXR tangential, mid-plane view on NSTX vacuum hardware mounted on 6” Conflat attached to port-mounted gate valve amplifiers mounted on back (atmosphere-side) of Conflat flange

  4. Abel inversion of tangential ME-SXR data shows detailed edge dynamics before profile crash • • 16 kHz internal MHD mode coupled to edge • edge MHD slows prior to profile crash • • SXR profile begins to flatten • strong steepening of edge emission profile prior to crash (possible C accumulation?)

  5. Atmospheric re-entrant ‘in-vessel’ design necessary to accommodate EAST port geometry

  6. ME-SXR assembly to be mounted at mid-planeon port side wall • • ME-SXR provides coverage from edge to mid-radius • FOV footprint in plasma can be adjusted by changing mounting position/angle

  7. In vessel housing provides compact systemfor ease of mounting

  8. Expanded view of ME-SXR assembly

  9. Toroidally-displaced core/edge ME-SXR systems currently proposed for EAST under DOE international solicitation • • ME-SXR proposed in “International collaboration to advance the three dimensional science of stability and control for long-pulse, high-performance tokamaks” Gates/Sabbagh • System designed to study lithium effects on ELM and MHD/NTM behavior, disruption pre-cursors and thermal quench, and positioned to study effects of planned 3D coils on plasma

More Related