1 / 27

IV Measurements on RD50 Sensors

IV Measurements on RD50 Sensors. Carl Goodrich 5-1-08. Inventory. 23 Boxes Each contains a long sensor (L) and two short sensors (S1 and S2) A “completed” box means we have IV measurements for all three sensors Boxes are grouped by: Type (P-type or N-type)

helen
Télécharger la présentation

IV Measurements on RD50 Sensors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IV Measurements on RD50 Sensors Carl Goodrich 5-1-08 Carl Goodrich- VELO Meeting

  2. Inventory • 23 Boxes • Each contains a long sensor (L) and two short sensors (S1 and S2) • A “completed” box means we have IV measurements for all three sensors • Boxes are grouped by: • Type (P-type or N-type) • Method for crystal growth (MCz or FZ) Carl Goodrich- VELO Meeting

  3. MCz (11 total) 10 completed 1 not completed FZ (11 total) 7 completed 4 not completed FZN (1 total) 0 completed 1 not completed P-type (11 total) 9 completed 2 not completed N-type (12 total) 8 completed 4 not completed Inventory- method and type 23 Boxes  17 completed Carl Goodrich- VELO Meeting

  4. Sensor: 2535-10 Type / Silicon Method: N-type / FZ Vbias Ground Carl Goodrich- VELO Meeting

  5. Sensor: 2535-8 Type / Silicon Method: N-type / FZ Vbias Ground What causes this dip? Carl Goodrich- VELO Meeting

  6. Time Between Runs Increasing time between runs Type / Silicon Method: P-type / MCz - Long Sensor Carl Goodrich- VELO Meeting

  7. Sensor: 2552-11 Type / Silicon Method: N-type / MCz Vbias Ground Carl Goodrich- VELO Meeting

  8. Sensor: 2553-13 Type / Silicon Method: P-type / MCz Vbias Ground Carl Goodrich- VELO Meeting

  9. Sensor: 2553-14 Type / Silicon Method: P-type / MCz Vbias Ground Carl Goodrich- VELO Meeting

  10. Effect of Irradiation • 4 Sensors were irradiated • Dose: 1E15 n equ / cm2 • Pre-irradiation measurements performed by Sadia • When returned, we did not know which sensors were which… Carl Goodrich- VELO Meeting

  11. Type / Silicon Method: P-type / MCz (1) and FZ (3) Ground Vbias Pre-Irradiation Guard Ring Current Total Current = + Bias Ring Current FZ MCz Carl Goodrich- VELO Meeting

  12. Irradiated Sensors- Results • The current increased by approximately 5 orders of magnitude. • To protect the sensors, we limited the current to 1mA. • The irradiated sensors obtained this current between 250V and 400V. • One sensor showed a significantly greater current, suggesting it might be the MCz sensor. Carl Goodrich- VELO Meeting

  13. Type / Silicon Method: P-type / MCz (1) and FZ (3) Vbias Ground Post-Irradiation Dose: 1E15 n equ / cm2 Carl Goodrich- VELO Meeting

  14. Type / Silicon Method: P-type / MCz (1) and FZ (3) Pre- and Post-Irradiation Post-Irradiation Note: We do not know which pre-irradiated sensor corresponds to each post-irradiated sensor Log Scale!!! Pre-Irradiation Carl Goodrich- VELO Meeting

  15. Backup Slides Carl Goodrich- VELO Meeting

  16. What circuit to use? • Biasing the rubber pad increases the current, especially after 600V. • Also increases the uncertainty in the measurement • Cannot measure the Guard Ring and Bias Ring currents separately. Carl Goodrich- VELO Meeting

  17. Czochralski (Cz) Method Method for forming single silicon crystals • Process: • Melt polysilicon • Introduce a single silicon “seed” and pull up slowly • Silicon freezes at the solid-liquid interface to form a single crystal Carl Goodrich- VELO Meeting

  18. Czochralski (Cz) Method • High concentrations of oxygen impurities • Increases the radiation hardness (RH) • Good- needed due to high radiation • Decreases the resistivity • Bad- high resistivity needed for detectors • Increase the resistivity by applying a strong magnetic field during growth • Magnetic Czochralski Method (MCz) Carl Goodrich- VELO Meeting

  19. Float Zone (FZ) Method Another method for forming single silicon crystals • Process • Place a single silicon “seed” below a polysilicon rod • RF coil (heater) moves upward • Silicon melts and refreezes as a single crystal Carl Goodrich- VELO Meeting

  20. Float Zone (FZ) Method • Low concentration of impurities • Low radiation hardness (RH) • Bad • High resistivity • Good • To increase RH, add: • Oxygen (DOFZ) • Nitrogen (FZN) Carl Goodrich- VELO Meeting

  21. References • Panja-Riina Luukka. Ph.D. Thesis. “CHARACTERIZATION OF CZOCHRALSKI SILICON DETECTORS.” INTERNAL REPORT SERIES. Helsinki Institute of Physics. • Gianluigi Casse's PhD thesis • http://hep.ph.liv.ac.uk/~gcasse/thesis.html Carl Goodrich- VELO Meeting

  22. Sensor: 2535-7 Type / Silicon Method: N-type / FZ Vbias Ground Carl Goodrich- VELO Meeting

  23. Sensor: 2552-9 Type / Silicon Method: N-type / MCz Vbias Ground Carl Goodrich- VELO Meeting

  24. Sensor: 2552-10 Type / Silicon Method: N-type / MCz Vbias Ground Carl Goodrich- VELO Meeting

  25. Sensor: 2552-12 Type / Silicon Method: N-type / MCz Vbias Ground Carl Goodrich- VELO Meeting

  26. Sensor: 2552-14 Type / Silicon Method: N-type / MCz Vbias Ground Carl Goodrich- VELO Meeting

  27. Sensor: 2553-12 Type / Silicon Method: P-type / MCz Vbias Ground Carl Goodrich- VELO Meeting