540 likes | 884 Vues
PXL-500/-510 Tiger Controller II. The PXL-500 Controller. Manages up to 65,535 cardholders Buffers up to 3,640 events Events stored in FIFO ( F irst- I n- F irst- O ut) order. The PXL-500 Controller. Controller addressing via push-button and LEDs NO dip switches to set.
E N D
PXL-500/-510 Tiger Controller II
The PXL-500 Controller • Manages up to 65,535 cardholders • Buffers up to 3,640 events • Events stored in FIFO (First-In-First-Out) order
The PXL-500 Controller • Controller addressing via push-button and LEDs • NO dip switches to set
The PXL-500 Controller • Auto configuration: • Doors software automatically downloads controller/network information - no manual data entry • Controller network termination
The PXL-500 Controller • Auto configuration: • Controller communication mode (direct connect, modem, Ethernet) • SB-593 Satellite board installation
The PXL-500 Controller • Inputs and Outputs are transient protected • Handles either • 1 or 2 Readers for single door In/Out controlOR • Two doors using optional SB-593 Satellite board
Power Specifications • Power - 12 VDC @ 1 A • Worst case current draw – with all features and options active • Current Draw • 120 mA for the PXL-500 • 150 mA for an SB-593 • 50 mA to 200 mA dependent upon reader type1 • 200 mA for a LAN-500 • Relay Contact Rating - 1A @ 24 VDC 1 – Wiegand readers may draw more current, refer to the reader’s manual for specifics
Wiring Specifications • RS-232 Serial Communication Cable • 3 conductor, shielded, stranded, AWG-2450 feet maximum run length (per RS-232 spec) • RS-485 Controller Network Cable • 1-pair, twisted, shielded, stranded, AWG-2416,000 feet total network run length
Wiring Specifications • Controller Power • 2 conductor, stranded, AWG-18 • 200 feet maximum run length • Earth Ground • Single conductor, AWG-18 (or larger gauge) • Minimize run length for best grounding conditions
Wiring Specifications • Input and Output Lines • 2 conductor, stranded, AWG-22 • 500 feet maximum run length • Readers • 6 conductor, shielded, stranded (for Keri Prox) • 4 to 7 conductor, shielded, stranded (for Wiegand, by reader type) • MS-3000, MS-4000, MS-5000 • 500 feet maximum run length with AWG-24 • MS-7000 • 500 feet maximum run length with AWG-20
Block Diagram - Communication RS-485 Controller Network RS-232 PC to Master Controller PXL-510 Serial Port PXL-510 Alarm Panel LAN-500 Ethernet
Block Diagram Unit Protection EE Prom Reader Connections
Block Diagram Status LEDs Address LED Battery
Controller Block Diagram Unit Power Inputs and Outputs Selection Switch
PCB Features • Microprocessors • CPU to manage controller general operation • RISC* processor to manage I/O processing • RISC* processor to manage the Reader receivers * (Reduced Instruction Set Computer )
PCB Features • Socketed EE Prom andPIC • Quick, easy firmware updates • Battery • 5-year, Lithium
PCB Features • Quick disconnect terminals for allwiring connections • Unique RS-485 connector • easily distinguish network connectionfrom other connections • Red power connector • easily distinguish power from other connections
Certifications • CE Declaration of Conformity • C-Tick • CSA C22.2 No. 142 • UL 508 Part XVII • FCC
Communications - PC to Master Controller • RS-232 serial port(TB-12) • Controller automatically detects connection type
Communications - PC to Master Controller • Via direct serial connection OR • Via a pair of modems
Communications - PC to Master Controller • Optional, plug-in TCP/IP module (TB-13) • Controller automatically detects TCP/IP connection • Jumpers reconfigure communication
Communications - Inter-Controller Network • RS-485 serial port (TB-1) • Auto-configuration of network termination • Total network length up to 16,000 feet • Network configuration flexibility • “T” and “star” configurations • Single, twisted-pair, shielded cable • Link up to 128 controllers and 256 doors
Communications - Options • PXL-510 – with second serial COM port • Used as the Alarm Panel interface (TB-11), connecting to Caddx NX8E alarm panels
Inputs • Inputs (TB-4) • Door Status • Request to Exit • Global Unlock (1) or • Aux/Secondary RTE (2) • Master controller only • Master or slave controllers
Outputs • Form-C Output Relays (TB-3) • Door Lock • Alarm • In a Form-C relay, the common always creates a complete circuit with either • The normally-open contact OR • The normally-closed contact
Readers • 2 Reader ports per Controller • Controls either 1 or 2 doors • In / Out control of 1 door • 2-door control with optional SB-593 board
Readers - PXL-500P • Exclusively for MS-Series Proximity Readers • MS-3000 • MS-4000 • MS-5000 • MS-7000 A-Reader: Single Door, In Door, or Door 1 (TB-5) B-Reader: Out Door or Door 2 with SB-593 (TB-6)
Readers - PXL-500W • For Wiegand compatible reader technologies • Pyramid Associates Readers (P-300, P-400, P-500, P-600, P-700) • Bar code, mag-stripe, biometric, etc. A-Reader: Single Door, In Door, or Door 1 (TB-5) B-Reader: Out Door or Door 2 with SB-593 (TB-6)
Readers - PXL-500W • Warning LED (LED-10) • Lights when 12 VDC is selected (as shown in picture) • Protects 5 VDC readers from over-voltage condition • Jumper selectable (JP-5) for either 5 or 12 VDC Wiegand readers (5 VDC is the factory setting)
Unit Addressing • LED Display • Address displayed via easy-to-read LEDs • Provides diagnostic information • Displays over or under supply voltage value
Unit Addressing • Selection Button (S1) • Set unit address • no DIP or rocker switches • no PC pre-configuring • Select diagnostic options
Unit Reset • Reset Jumper (JP3) • Clears unit memory and resets unit • Used in conjunction with S1
Master versus Slave Operation • Master Controller • Must be assigned address “01” • Manages communication between host PC and the controller network • Handles presentation card enrollment (using A-Reader), Show Photo, and ID Card features • Slave Controllers • Can be assigned any other unique address from “02” to “128” • Do not have to be addressed in sequential order
Status LEDs • TXD and RXD for RS-232 • LEDs 2 and 3 for primary serial port • LEDs 4 and 5 for optional serial port • LEDs flicker red/green as data is transferred
Status LEDs • Lock Relay • Lights when relay is active • Alarm Relay • Lights when relay is active
Status LEDs • Power • Lights GREEN when power is ON and OK • Lights RED when power is over or under specification • Communications for RS-485 • Flickers red/green as data is transferred
System Protection • The PXL-5xx controller has the following system protection features: • Metal-oxide Varistors • Transorbs • Gas Discharge Tube • Fused over/under voltage detection • Power status LEDs • Socketed RS-485 IC
System Protection • Power Status (Fuse) LED • Warns the installer of unsafe power conditions • Glows RED if power is reversed • Glows GREEN if there is a power line short or an over current draw condition
System Protection • Gas Discharge Tube • Protect the PCB from damage caused by transients and power surges • MOVs • Protect relays from damage caused by transients and power surges
System Protection • Socketed RS-485 communication IC • For quick repair of damage caused by voltage spikes
System Protection • Thermal Fuse opens under unsafe power or current conditions • CAUTION – Do not touch this component, it is very hot during operation
System Protection • Transorbs protect all signal inputs from damage caused by transients and power surges
Environmental Operating Range • Temperature • 0° to 140 °F (-18° to 60° C) • Humidity • 0% to 90% relative humidity, non-condensing
SB-593 Satellite Expansion Board • Jumper selectable for either: • Second door control with 2 programmable outputs and 6 programmable inputs OR • 4 programmable outputs and 8 programmable inputs • Uses Form C relays
SB-593 Satellite Expansion Board • Snaps into place on the PXL-500 controller • align header connectors and plastic mounting pins to corresponding locations on controller and press into place • Installation LEDs • indicates correct board installation
SB-593 Satellite Expansion Board • Controller auto-detects an installed SB-593 • no additional configuration needed • Status LEDs • Indicate relay active/inactive status • Relay Contact Rating • 1A @ 24 VDC
Options - LCD-1 • LCD-1 - plug-in liquid-crystal display for: • Firmware revision • Date and time • Diagnostic information
Options - LAN-50/100/500 • Provides low cost TCP/IP communication using either: • LAN-50/100 external modules • LAN-500 plug-in module • IT experience required for proper configuration of LAN device
Options - Alarm Panel Interface • Fully integrated access and alarm panel control using the secondary serial port on the PXL-510 panel • Interfaces with the Caddx NX-8E alarm panel