An Introduction to TR-55

An Introduction to TR-55. Kristina Schneider February 27, 2001. Model Overview. Applies to small urban and urbanizing watersheds but can be used with other watersheds if limitations are met. Uses simplified methods for estimating: Storm runoff volume (SCS Method)

Albert_Lan
Télécharger la présentation

An Introduction to TR-55

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. An Introduction to TR-55 Kristina Schneider February 27, 2001

  2. Model Overview • Applies to small urban and urbanizing watersheds but can be used with other watersheds if limitations are met. • Uses simplified methods for estimating: • Storm runoff volume (SCS Method) • Peak rate of discharge (Graphical Method) • Hydrographs (Tabular Method) • Storage Volumes (Quick Manual Method)

  3. Rainfall • Includes four regional 24 hour rainfall distributions • The critical parameter is the time of concentration. • Tc = Sum ( Time of travel for segments) Tt = L/V

  4. Rainfall Distributions • Types I and IA – • Pacific maritime climates with wet winters and dry summers • IA is the least intense rainfall • Type III – • Atlantic coastal areas and the Gulf of Mexico where tropical storms with large 24 hour rainstorms occur. • Type II – • The rest of the country • Most intense short duration rainfall

  5. Rainfall Distributions

  6. Rainfall Distributions

  7. SCS Runoff Curve Number Method Runoff Rainfall

  8. Runoff Calculation Limitations • CNs are for average conditions • Does not account for rainfall intensity or duration • Less accurate when runoff is less than 0.5 inches

  9. Graphical Peak Discharge Method • Allows you to calculate the peak discharge • Equation: qp = quAmQFp qp = peak discharge(cfs) qu = unit peak discharge (csm/in) Am = drainage area (mi2) Q = runoff (in) Fp = pond and swamp adjustment factor

  10. Graphical Peak Discharge Method • Inputs: • Tc (hr) • Drainage Area (mi2) • Appropriate Rainfall Distribution (I, IA, II, or III) • 24-hour Rainfall (in) • CN

  11. Graphical Peak Discharge Method • Use Inputs to find the Ia/P ratio

  12. Graphical Peak Discharge Method • Determine qu with Tc, Ia/P, and rainfall distribution type. Example distribution There is one distribution for each rainfall type. qu Tc

  13. Graphical Peak Discharge Method Worksheet available to aid in calculation • See Worksheet 4 in the back of your slides • Limitations • Can only be used for peak discharge • Watershed must be homogenous • Only one main stream • Cannot perform valley or reservoir routing • Ia/P must be in range given in the manual (3.000 – 0.041)

  14. Tabular Hydrograph Method • Used to compute peak discharges from rural and urban areas. • Can develop partial composite flood hydrographs for any point in the watershed by dividing up the watershed into homogenous subareas. • Also, can be used for estimating the effects of proposed structures.

  15. Tabular Hydrograph Method • Required Information: • Subdivision of the watershed into areas of homogenous watershed characteristics • Drainage Area (mi2) • Tc (hr) • Tt – time of travel for each reach (hr) • Weighted CN • Appropriate Rainfall Distribution (I, IA, II, or III) • Total Runoff (in) • Ia for each subarea • Ia/P ratio of each subarea

  16. Tabular Hydrograph Method:Composite Flood Hydrograph • Use worksheet 5a to summarize the basic watershed data • Worksheet 5b is used to develop the tabular discharge summary • q= qtAmQ q= hydrograph coordinate (cfs) at hydrograph time t qt=tabular unit discharge located in exhibit 5 (csm/in) depends on rainfall distribution Am = drainage area of individual subarea (mi2) Q = runoff (in)

  17. Storage Volume for Detention Basins: Manual Method • Quick way for planners to examine multiple alternatives. • Good for both single- and multi-stage storage basins • Constraints • Each stage requires a design storm • A storage is calculated for each stage

  18. Storage Volume for Detention Basins: Manual Method • Use Worksheet 6a to calculate the volume of storage (Vs) if the following factors are known: • qo = peak outflow discharge • qi = peak inflow discharge • Vr = runoff volume • Use Worksheet 6b to estimate qo The worksheets are in the back of your handout.

  19. Storage Volume for Detention Basins: Manual Method

  20. Storage Volume for Detention Basins: Manual Method • Limitations • Less accurate as the qo/qi ratio reaches the limit of the relationship graph • Biased towards overestimating the storage needed • Should be used as an initial design step

  21. General Limitations • Flow is based on open and unconfined flow over land or in channels. • Graphical Method is used only for homogenous watersheds. • Tabular Method can be used for heterogeneous watersheds divided up into homogenous subwatersheds. • Approximate storage-routing curves should not be used if the adjustment for ponding is used.

  22. References • Soil Conservation Service (SCS), Urban Hydrology for Small Watersheds, Tech. Release 55, Washington, DC. 1986. Available online at http://www.wcc.nrcs.usda.gov/water /quality/common/tr55/tr55.pdf • McCuen, R.H., Hydrologic Analysis and Design, Prentice-Hall, Inc., Englewood Cliffs, NJ, 1998.