1 / 12

Wireless IP Surveillance Solution

Design and Deployment of Wireless Surveillance system for monitoring Cement industry.

Blaze_Hyd
Télécharger la présentation

Wireless IP Surveillance Solution

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Wireless IP Surveillance Solution

  2. Problem Statement • Design and Deployment of Wireless Surveillance system for monitoring Cement industry.

  3. Contents of the presentation • Details of various Solutions from BLAZE Automation. > Basic Solution with External Power Supply > Advanced solution with Solar Power Supply • Pricing and Other details of each solution. • Our recommendations

  4. Basic Solution • Objectives and requirements: • Provide Wireless Access points at each bunker to which a stand alone camera with night vision will be attached. This video will be relayed through the WAP to a bunker monitoring station / central station corresponding to that bunker where the Mine manager / Surveyor can view the video in the PC deployed over there. • The following are the equipment required at each bunker for relaying the video to the Central station / Unit corresponding to that bunker. • 1. IP Camera with night vision capability (1 in number) : There are various models depending on your requirement. The details are furnished in the quotation provided(singareni_CCTV_basicquote.pdf). • 2. WAP equipment with inbuilt directional patch antenna and other required accessories. Please refer the quotation for your reference (singareni_CCTV_basicquote.pdf). • 3. Power supply unit , surge suppressor , Lightening protector etc… • 4. Nine (9) such setups are required as there are 9 bunkers all over.

  5. Basic Solution (contd…) • Equipment required at the central unit : • 1. WAP equipment with inbuilt directional patch antenna and other required accessories. Please refer the quotation for your reference (singareni_CCTV_basicquote.pdf). • 2. Power supply unit , surge suppressor , Lightening protector etc… • 3. Nine (9) such setups are required as there are 9 bunkers all over.

  6. Basic Solution – Infrastructure at each Bunker Infrastructure at Bunker Central Unit Infrastructure Line of Sight comm link

  7. Basic Solution – Connection diagram at Bunker / Central unit

  8. Advanced Solution • Objectives and requirements: • This is nothing but basic solution + solar power pack for 24/7 power backup. This constitutes a solar power pack at each Bunker which can provide a power backup for 3 days autonomy. The PV panel and the battery components will be chosen accordingly. Also this can be supplemented with AC mains which can help in the situation of continuous power failure for three days in rainy season especially. • Provide Wireless Access points at each bunker to which a stand alone camera with night vision will be attached. This video will be relayed through the WAP to a bunker monitoring station / central station corresponding to that bunker where the Mine manager / Surveyor can view the video in the PC deployed over there. • The following are the equipment required at each bunker for relaying the video to the Central station / Unit corresponding to that bunker. • 1. IP Camera with night vision capability (1 in number) : There are various models depending on your requirement. The details are furnished in the quotation provided(singareni_CCTV_advancequote.pdf).

  9. Advanced Solution (contd…) • 2. WAP equipment with inbuilt directional patch antenna and other required accessories. Please refer the quotation for your reference (singareni_CCTV_advancequote.pdf). • 3. Power supply unit , surge suppressor , Lightening protector etc… • 4. Nine (9) such setups are required as there are 9 bunkers all over. • Equipment required at the central unit : • 1. WAP equipment with inbuilt directional patch antenna and other required accessories. Please refer the quotation for your reference (singareni_CCTV_advancequote.pdf). • 2. Power supply unit , surge suppressor , Lightening protector etc… • 3. Nine (9) such setups are required as there are 9 bunkers all over.

  10. Advanced Solution – System Architecture in Detail at each Bunker. Please find the detailed Image in the attachment provided with this Email under the following name: Blaze Wireless Surveillance system .jpg

  11. Advanced Solution- Typical layout for 3 bunkers and one Central unit.

  12. Thank you Sridhar Ponugupati Chief Executive Officer Blaze Automation Mobile: +91 9440490408

More Related