1 / 3

IMI FAS Watson Smith 8mm CHIPSOL MS Direct acting Solenoid Valves

"CHIPSOL features the performance of a 10mm solenoid valve in an 8mm body. Industry-leading flow to size ratio, 0.5W power consumption, cartridge mount, and excellent repeatability make it ideal for integration in portable devices. CHIPSOL platform includes on/off, proportional, and media separated valves.<br><br>2/2 NC media separated<br>Cartridge or manifold mounting<br>Long-life up to 30 million cycles""<br>"<br>For More Information visit on our website:- www.instronline.com<br>Our E-mail Address:-info@instronline.com <br>

Instronline
Télécharger la présentation

IMI FAS Watson Smith 8mm CHIPSOL MS Direct acting Solenoid Valves

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FAS 8 mm CHIPSOL MS Direct acting solenoid valve > 2/2 NC Media separated Cartridge or manifold mounting > Low internal volume, virtually no unswept volume > Very compact design (ø 8 x 21 mm) > Low power consumption (0,5 W) > Long life up to 30 million cycles > 100% ED operation up to 50°C fluid temperature Technical features Medium: Neutral or aggressive gases and liquids Operation: Direct acting 2-way valves, normally closed Operating pressure: 0 ... 2,1 bar (0 ... 30 psi) at port 1 0 ... 0,2 bar (0 ... 2,9 psi) at port 2 0,5 bar (7,2 psi) maximum back pressure at port 2 Mounting: Cartridge or manifold Size: 8 mm Orifice: 0,8 mm Response time: < 15 ms Response time measured according to ISO 12238 Life expectancy: ≥30 Mio. cycles Ambient/media temperature: -10 ... +50 °C (+14 ... +122°F) Air supply must be dry enough to avoid ice formation at temperatures below +2 °C (+35°F). Materials: Body in contact with media: PEEK Seat seals: EPDM or FFPM Electrical details Following options on request Voltage: Rating: Voltage tolerance Power consumption: Electrical insulation Insulation class 12 & 24 V d.c. 100 % E.D. ± 10% 0.5 [W] 500 V a.c. F (155°C) kv Operating pressure Medium temperature Ambient temperature Power consumption Electric connection Voltage (3, 5 or 6 V d.c.) Manifold for catridge version Sub-base material Pulse width modulation (PWM) control A PWM can be used to control the valve and should be set as follows: Definition Voltage used for he valve to commute Voltage applied to he valve after commutation Value to be applied Valve nominal voltage Set duty cycle to guarantee specified holding voltage. 50% of nominal voltage can be used if no value specified. Hit voltage Holding voltage Hit time PWM frequency Maximum time required to ensure full valve commutation 40 ms at T > 15 °C *1) ~20 kHz *1) Please contact us for application outside of those conditions. Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2014 - 5016c) © 2015 Fluid Automation Systems s.a. 6/15 en 5.2.022.01

  2. FAS 8 mm CHIPSOL MS Direct acting solenoid valve Technical data - standard models Symbol Mounting op- tion Voltage (V d.c.) Seal Material Drawing No. Model Manifold Manifold Cartridge Cartridge Manifold Manifold Cartridge Manifold 12 12 12 12 24 24 24 24 EPDM FFPM EPDM FFPM EPDM FFPM EPDM FFPM 2 2 1 1 2 2 1 1 14-213EM01-B5+AWF 14-213EM01-B6+AWF 14-213CM01-B5+AWF 14-213CM01-B6+AWF 14-213EM01-B5+AYJ 14-213EM01-B6+AYJ 14-213CM01-B5+AYJ 14-213CM01-B6+AYJ 2 12 10 1 Accessories 12 2 0 Electrical connection 2 10 Manifold (PEEK) 300 mm flying leads mounted with 4 mm (or 2 x 2 mm) pitch SIL socket housing (Harwin M22-3010300) Page 3 S140.0361 (M5 ports) S140.0362 (1/4-28 UNF ports) S141.0466 *1) Two valve mounting screws are in scope of delivery Typically flow rate vs back pressure l/min Inlet pressure (bar) 10 2,5 9 8 2,0 7 Air flow 1,5 6 5 1,0 4 0,5 3 2 1 0 bar 0 0,05 0,1 0,15 0,2 0,25 0,3 0,35 0,4 0,45 0,5 Back pressure Typically response time vs temperature m/s 15 Response time 10 Electric (TE) Pneumatic (T on 10%) Pneumatic (T off 90%) 5 0 0 10 20 30 40 50 60 °C Temperature Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2014 - 5016c) © 2015 Fluid Automation Systems s.a. en 5.2.022.02 6/15

  3. FAS 8 mm CHIPSOL MS Direct acting solenoid valve Dimensions Cartridge valve 1 Dimensions shown in mm Projection/First angle Manifold valve 2 5 5 5 ± 0,05 2,5 <1,1 2 2 (5,5) 14,5 ø7,9 ø7,9 1,35 1,35 1 1 ≤21 5 ≤21 5 2 1 0,5 0,5 M1,6 3 4 4 3 3 > 10 1+ 0,02 0 3,6± 0,025 7,8+ 0,05 0 ø6,3 ± 0,05 ø8,1± 0,1 < 1,1 4 1 Inlet port 2 Outlet port 3 Do not weld 4 Pins ø 1 h8 x >10 (ISO 2338) not in scope of delivery 5 Sealing area ø1,75+ 0,05 ø2,5+ 0,05 0 0 2,25+ 0,05 0 2,5 3,1+ 0 ± 0,05 All valves are supplied with gasket. Mounting screws are in scope of delivery for manifold valve as well. 0,1 > 5 0,8 Manifold Model: S140.0361 (M5); S140.0362 (1/4-28 UNF) (PEEK) 1 4 17 3,1 3 11,5 16 2 1,1 5 3 4 8 3 1 Threads for mounting screws - M2 x 5 mm deep 2 Mounting hole 3 Threads to fix valve in position - M1,6 x 6 mm deep 4 Sealing surface 5 Port size M5 or 1/4-28 UNF 2,5 11,3 23 Warning These products are intended for use in industrial compressed air, neutral or aggressive gases only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features«. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult IMI FAS. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2014 - 5016c) © 2015 Fluid Automation Systems s.a. en 5.2.022.03 6/15

More Related