1 / 31

A COMMON R&D ON THE HIGH GRADIENT Nb CAVITIES

A COMMON R&D ON THE HIGH GRADIENT Nb CAVITIES. Kenji Saito Takayuki Saeki Yasuo Higashi Fumio Furuta. Bernard Visentin Fabien Eozénou Mélanie Bruchon. A CRUCIAL R&D ON HIGH GRADIENT Nb CAVITIES. International Linear Collider ~ 17000 Superconductive Nb cavities > 31.5 MV/m 1 Tev.

abradshaw
Télécharger la présentation

A COMMON R&D ON THE HIGH GRADIENT Nb CAVITIES

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A COMMON R&D ON THE HIGH GRADIENT Nb CAVITIES Kenji Saito Takayuki Saeki Yasuo Higashi Fumio Furuta Bernard Visentin Fabien Eozénou Mélanie Bruchon - Fabien Eozénou - FJPPL 2008 A_RD_04

  2. A CRUCIAL R&D ON HIGH GRADIENT Nb CAVITIES - Fabien Eozénou - FJPPL 2008 A_RD_04

  3. International Linear Collider ~17000 Superconductive Nb cavities > 31.5 MV/m 1 Tev TWO MAIN ROJECTS RELATED TO THE “COLD” TECHNOLOGY • XFEL (X-Ray Free-Electron Laser) • 17.5 GeV λ=0.1nm • 808 cavities E=23.5 MV/m assembled in 101 cryomodules - Fabien Eozénou - FJPPL 2008 A_RD_04

  4. Electro-Polishing (EP) And Baking: Reminder ‘Standard’ preparation to reach high gradients: Barrel Polishing + EP + Anneal + Final EP + HPR + Rinse + Baking Electro-Polishing: Internal Surface Treatment of the Cavity filled with acid in presence of Current Standard Baking: Cavity is baked under vacuum to remove high field Q-Slope whose origin remains mysterious ‘Standard’ parameters: 120°C: 48h - Fabien Eozénou - FJPPL 2008 A_RD_04

  5. Process - Nb polished internally with an electrolyte (concentrated H2SO4 - HF mixture) under voltage - Cavity = Anode & Cathode is an Al pipe inside the cavity Chemical reactions - Anode: Niobium oxidation 2 Nb + 5 H2O  Nb2O5 + 10 H+ + 10 e- - Cathode: H2 generation 2 H+ + 2 e- H2 (Teflon net to prevent H contamination) - HF: dissolution of oxide Nb2O5 layer - H2SO4: forming of a viscous layer Electro-Polishing (EP): More details - Fabien Eozénou - FJPPL 2008 A_RD_04

  6. Electro-Polishing (EP) and Baking: Main Breakthroughs Nb Cavity Performances ( 1991 - 1999 ) Continuous improvements with Heat Treatments @ 800 and 1400°C, High Pressure Rinse, Baking & ElectroPolishing. 42 MV/m hard barrier (  2004 ) - Fabien Eozénou - FJPPL 2008 A_RD_04

  7. GOALS OF THE COMMON R&D PROGRAM • Improvement of the Baking Procedure: • Facilitate the baking procedure • Decrease the baking time • Improvement of Electro-Polishing: • Obtaining of high reproducible gradients • Better understanding of the process (use of modelling) - Fabien Eozénou - FJPPL 2008 A_RD_04

  8. IMPROVING THE BAKING PARAMETERS - Fabien Eozénou - FJPPL 2008 A_RD_04

  9. FAST ARGON BAKING B.Visentin IR baking system in Clean Room at Saclay. Use of Argon Instead of high Vacuum 120°C 48h 145°C 3h In terms of Oxygen diffusion in the bulk niobium - Fabien Eozénou - FJPPL 2008 A_RD_04

  10. BAKING RESULTS ON ICHIRO CAVITIES “Ichiro” (or Low Loss) Geometry makes it possible to reach higher gradients → Two cavities received from KEK IS8 Baked under argon during 1 hour at 145°C → + 9MV/m + 1hour additional baking : removal of residual slope. 2 hours = optimal duration for “fast argon” baking Will be presented at EPAC 2008: MoPP154 (B. Visentin et al.) An additional test will be done to reach the quench - Fabien Eozénou - FJPPL 2008 A_RD_04

  11. IMPROVING THE EP PARAMETERS - Fabien Eozénou - FJPPL 2008 A_RD_04

  12. LOW REPEATITIBILITY TESTS ON 9-CELL CAVITIES SHOW A LOW REPEATITIBLITY OF THE GRADIENT COMPARED TO THE CHEMICAL POLISHING. MANY CAVITIES ARE LIMITED BY FIELD EMISSION. IT IS NECESSARY TO IMPROVE RINSING PROCEDURES. - Fabien Eozénou - FJPPL 2008 A_RD_04

  13. ILC GDE S0 PROGRAM ON SINGLE CELL ILC S0 International Program on single-cell cavity: Different Rinsing procedures are evaluated: 6 tests for each “recipe” to have statistics: - Fabien Eozénou - FJPPL 2008 A_RD_04

  14. EXAMPLE: EVALUATION OF FRESH EP AT KEK - Fabien Eozénou - FJPPL 2008 A_RD_04

  15. RESULTS WITH ETHANOL RINSING WITHIN GDE S0 PROGRAM ON 1-CELL Test Within S0 program on single cell: Recipe: Light EP + 30’ Ethanol Rinsing + HPR Mixture: HF(40%) - H2SO4 (95%) with ratio 1 – 9 3 Cavities (Tesla Shape): Before EP at Saclay: • 1DE1: 37 MV/m • 1DE3: 30 MV/m • 1C03: 40 MV/m - Fabien Eozénou - FJPPL 2008 A_RD_04

  16. RESULTS FOR 1DE1 AND 1DE3 CAVITIES - Fabien Eozénou - FJPPL 2008 A_RD_04

  17. SUMMARY FOR THE 6 TESTS FOR S0 - Fabien Eozénou - FJPPL 2008 A_RD_04

  18. FINAL TABLE AND AVERAGE GRADIENT *Additional HPR At Saclay before Test #2 For the 5 EP on Desy Cavities Eacc Max = 41.35 +/- 1.27 Q0 @ Eacc Max= 1.29E10 +/- 5.27E9 ETHANOL RINSING + HPR SHOULD BE CONSIDERED AS A RELIABLE RECIPE! - Fabien Eozénou - FJPPL 2008 A_RD_04

  19. SEARCH FOR NEW PARAMETERS: EP at LOWER VOLTAGE (5V) PROCESS EASY TO CONTROL! = Current Oscillation Regime at any Temperature and stirring conditions. + It does not seem to depend on bath aging. + Low heating of the Bath Surface after 130 µm EP at 5V • Tests With 1C21 Cavity: 2 sequences: 80 µm + 50 µm +Ethanol Rinsing. EP at low temperature first (~20°C) • Very Bright and little grainy surface Ratio Removal @ Iris / Removal @ Equator seems promising 110 µm / 90 µm in the half cell were acid is better renewed Lower than for Standard EP (17V) ? → To be confirmed What is the result in terms of RF performance?... - Fabien Eozénou - FJPPL 2008 A_RD_04

  20. RF RESULTS AFTER LOW VOLTAGE EP Promising Result :1C21 cavity belong to a batch of cavities that show poor results after BCP (Baking Resistant cavities! Eacc<20 MV/m) OUTLOOK: → EP at low Voltage with ICHIRO/1DE1 Cavities + Standard EP on 1C21 → EP at higher temperature to increase the removal rate - Fabien Eozénou - FJPPL 2008 A_RD_04

  21. IMPROVING THE EP PROCESS - Fabien Eozénou - FJPPL 2008 A_RD_04

  22. IMPORTANCE OF THE FLUID DISTRIBUTION Example of study of the process by E. Kako (KEK) - Fabien Eozénou - FJPPL 2008 A_RD_04

  23. Composition of the bath: In practice: Mixture of hydrofluoric and sulfuric acids (1:9 in volumes) Modelling: Density and viscosity of sulfuric acid Nb oxydation: 2 Nb + 5 H2O → 5 H2 + Nb2O5 (1) Nb2O5 + 10 HF → 2 H2NbOF5 + 3 H2O (2) Modelling: Only equation 2, Nb2O5 is continuously formed Kinetic equation: HOW CAN MODELLING HELP US? STUDY WITH COMSOL SOFTWARE M. Bruchon Is the standard EP responsible for the dissymmetric attack of the surface? →Modelling of fluid dynamics and chemical reactions in 2D • x is the production of H2NbOF5 at time t, α and β the initial concentration of Nb2O5 and HF - Fabien Eozénou - FJPPL 2008 A_RD_04

  24. Phenomenon transport : High concentrated electrolyte Diffusion Migration Convection • Navier Stockes equation (incompressible fluid) • Electroneutrality • Gravity effect • HF concentration versus time and fluid velocity GENERAL EQUATIONS • Mass balance equation: - Fabien Eozénou - FJPPL 2008 A_RD_04

  25. ASSYMETRIC EP FOR SINGLE-CELL CAVITIES Modelling of Saclay EP Set-up for different shapesof single cell Velocity LL TESLA HF Left beam tube is badly swept by the acid Acid “rebounds” on the right iris HF Velocity - Fabien Eozénou - FJPPL 2008 A_RD_04

  26. Velocity field HF at 20 000s IMPROVEMENT FOR SINGLE-CELL CAVITIES Inflow and outflow like 9-cells cavities New symmetric acid distribution → more uniformattack (be careful for the irises) Will be experimentally testedat Saclay - Fabien Eozénou - FJPPL 2008 A_RD_04

  27. Specifications from KEK (size of holes, inflow and outflow of acid) Fluid velocity [HF] at 4 000 s [HF] at 20 000 s 9-CELL CAVITIES MODELLING ICHIRO Cavities TESLA Cavities HF Velocity Good electropolishing of central cell #5 Electropolishing needs to be improved in the other cells Explanation to the field flatness degradation experimentally observed at KEK after electropolishing ? →Outlook: 3D Modelling, Alternative cathode shape - Fabien Eozénou - FJPPL 2008 A_RD_04

  28. IMPROVING THE INFRASTRUCTURES - Fabien Eozénou - FJPPL 2008 A_RD_04

  29. NEW EP FACILITY AT KEK 9-Cell Cavity EP at Nomura Plating Building of a new set-up for 9-Cell cavities EP at KEK http://www.linearcollider.org/newsline/readmore_20080327_atw.html - Fabien Eozénou - FJPPL 2008 A_RD_04

  30. STUDY FOR 9-CELL EP SET-UP IMPLEMENTATION AT SACLAY - Fabien Eozénou - FJPPL 2008 A_RD_04

  31. Ultra Pure water plant XFEL cold mass assembly 6.5 m X 14 m XFEL cryomodule assembly 4.4 m X 35 m SPIRAL2, SOLEIL, … cryomodule assembly10 m X 13 m NEW EQUIPMENT EXISTING EQUIPMENT Preparation and Assembly Facilitiesfor SRF Activities at Saclay Surface characterization (optical microscope, MEB, SIMS, …) chemical treatment of multicell cavities (+US and UP water rinsing) CLEAN ROOMS ISO 7 (class 10000) 6 x 7.5 m ISO 5 (class 100) 6 x 6 m ISO 4 (class 10) 6 x 14.4 m EP multi-cells Chemistry storage area Gas cleaning plant CP monocell EP monocell R&D on samples - Fabien Eozénou - FJPPL 2008 A_RD_04

More Related