1 / 7

XP723: Momentum transport and the effect of rotation on confinement

XP723: Momentum transport and the effect of rotation on confinement. Make use of n=3 NRMP for rotation braking in various degrees Steady-state application: effect of v f on energy confinement; s-s momentum confinement/diffusivity (includes offset)

aisha
Télécharger la présentation

XP723: Momentum transport and the effect of rotation on confinement

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. XP723: Momentum transport and the effect of rotation on confinement • Make use of n=3 NRMP for rotation braking in various degrees • Steady-state application: effect of vf on energy confinement; • s-s momentum confinement/diffusivity (includes offset) • Perturbative application: Transient determination of momentum • confinement/diffusivity (offset can be ignored) • Make use NTV theory to determine n=3 torque • Main goals of XP were achieved (not enough good shots to • assess reproducibility, no pCHERS) Vf at R=131 cm Vfat center IRWM

  2. Momentum Diffusivity Does Not Show Any Clear Relation to Either Ion or Electron Diffusivities • cf ~ cI indicates importance of ITG modes • ExB suppression of these modes may be the cause of the lack of this relation in NSTX Use EF/RWM coils to control rotation (Er) to reduce ExB suppression Does cf ~ cI relation return?

  3. Run Plan • Use relatively MHD quiescent discharge as baseline • Still deciding: want something that is relatively long “steady-state” (400 ms), including rotation • May want to use a discharge with optimal error field correction developed early in the run • Impurity injection element needs several hundred ms for transport assessment • Establish baseline discharge • Inject impurity in comparison shot to see if non-perturbing (if so, can use impurity injection throughout rest of XP, with comparison shots every so often to check “perturbery” • Two phases of XP • Steady-state application of EF/RWM field to test effect of rotation on energy and impurity transport, determine “steady-state” momentum diffusivity/confinement • Perturbative application of EF/RWM to determine momentum diffusivity & pinch from transients • Space transient applications to be several tf(20-50 ms)

  4. Run Plan (cont’d) • Baseline Shot Development (2-4 discharges) • Determine maximum EF/RWm current for achieving near zero rotation (Imax) • Steady-State • EF/RWM on at 300 ms • Impurity injection at 350 ms • Four conditions (2 shots/condition) – 8 discharges • Shot Condition • 1 IRWM=0 • 2 IRWM=IMAX • 3 IRWM=1/3 IMAX • 4 IRWM=2/3 IMAX

  5. Run Plan (cont’d) • Constant EF/RWM “blips” for transient analysis (total 6 discharges) Shot Condition 1 Imax 2 2/3 Imax 3 1/3 Imax __________________________ • Step-up “blips” (total 4 shots) Shot Condition 1 3 steps 2 2 steps

  6. Run Plan (cont’d) • Step-down “blips” (total 4 shots) Shot Condition • 3 steps • 2 steps Total: 26 shots (a healthy day)

More Related