1 / 77

Red Lion Controls

Red Lion Controls. Company Introduction. Founded in 1972 Located in York, Pennsylvania Employees 166 people Part of Spectris, the productivity-enhancing instrumentation and controls company. Beginnings.

alaina
Télécharger la présentation

Red Lion Controls

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Red Lion Controls Company Introduction

  2. Founded in 1972 • Located in York, Pennsylvania • Employees 166 people • Part of Spectris, the productivity-enhancing instrumentation and controls company. • Beginnings

  3. Spectris plc (www.spectris.com) is a public company listed on the London Stock Exchange (Symbol - SXS) with annual sales approaching £800million (1.33 billion USD in 2008). • Headquartered in Egham, England, Spectris supplies productivity-enhancing instrumentation, equipment and controls to a diverse range of end-use markets on a global basis. • The group comprises thirteen principal operating businesses organised into four divisions; Industrial controls, Materials Analysis, Test & Measurement and In-line Instrumentation • Spectris plc - division

  4. 90% of Red Lion’s business is distribution • 600+ distributors worldwide • 5% is catalog sales • 5% is direct customers • Channels

  5. Red Lion produces most of its products in the USA. • Manufacturing covers over 100,000 Sq. ft. • Most products ship from stock • Manufacturing

  6. Protocol Gateway Operator Interface Process Controller • Product suite – 3,000 products Interface Indication Panel Meters Signal Conditioner Sensors

  7. All-in-one data management • More than a gateway • Protocol conversion • Data collection • Web server • Remote access • Data Station Plus (DSP) – Communications gateway and much more! Data Station Plus (DSP)

  8. Convert over 200 protocols • Mitsubishi Omron Panasonic • Yaskawa Yokogawa Koyo • Allen-Bradley Siemens Honeywell • And many more • Share data on any port with any other ports • Ethernet port capable of TEN protocols • Three serial ports • Drag-n-drop data mapping • Protocol Conversion

  9. Expansion cards for other networks • DeviceNet • ProfibusDP • CAN • J19393 • Extra serial ports (2) • Cell Modem - GSM • Protocol Conversion - continued

  10. Collect: • Data logs • Security logs • Alarm and event logs • Custom logs • Use built in math and logic functions • Data Collection

  11. Direct to CSV file • Excel ready • Save to compact flash • No special software required • Set files for shift, day, month, etc. • Auto-reset • Automatically send files to FTP • Automatically send files by email • Data Collection - continued

  12. Built-in, no software required • Uses standard web browser • See actual visualization • Or see data only • Via Ethernet, modem, or serial • Upload logged files • Download configurations • Add you own web pages • Web Server

  13. Download configurations • Upload logged files • Pass through programming to PLC • Program alarms and events • Email alarms or events • Text message alarms or events • Remote access • Serial • LAN • Analog modem • Cellular modem • Remote Access

  14. C-style programming • User security • USB programming port • Includes Crimson S/W • Crimson is included • Download from our website • Still More

  15. Operator Interface G3 series G3 Kadet series

  16. Operator Interface + DSP = Display G3 series

  17. Same functions as DSP plus a display, keypad, touchscreen • Protocol conversion • Data collection (CompactFlash) • Web server • Remote access • Includes Crimson S/W • Ten Ethernet protocols • 3 serial ports • Indoor / outdoor units • Touchscreen • And keypad • G3 Series

  18. 3" monochrome unit non-touch keypad only • 6" QVGA, color TFT and mono, indoor/outdoor • 8" VGA, color TFT and DSTN, indoor/outdoor • 10" VGA color TFT, indoor/outdoor • 15" XGA color TFT, indoor/outdoor • Expansion cards • Cellular modem (GSM) • DeviceNet • CANopen • J1939 • ProfibusDP • Serial - 2 ports • G3 Series - continued

  19. When all the features of standard G3 are not required • Includes Crimson S/W • Protocol conversion • 2-3 serial ports • Ethernet on 6" • CF to install database • 4" 480x272 pixels, color TFT, 2 serial ports • 6" QVGA, color TFT, 3 serial ports, Ethernet • G3 Kadet Series 6" 4"

  20. Process Controllers Dual Loop Controller Modular Controller Single loop temperature controller Single loop process controller

  21. Modular Controller + DSP PID and I/O modules = Modular controller

  22. Same functions as DSP plus I/O • Includes Crimson S/W • Add I/O as needed, up to 16 modules • Manage up to 32 multi-zone PID loops • Great data acquisition platform • Hot swap modules • Module types: • PID modules • Analog input • Analog output • Digital I/O • Strain gage • Thermocouple • RTD • Modular Controller - continued

  23. Enable the plant floor to speak • Plant Floor Marquee (PFM) Plant Floor Marquee (PFM)

  24. Increase productivity • Key performance indicators • Uptime • Downtime • Parts produced • OEE • Overall equipment effectiveness • Measurement of asset utilization • Andon • Alarms • Machine down • machine jammed • Parts outage • PFM Series

  25. Four tricolor graphical displays • Different models for 115 or 230 VAC • RS-485 port allows multi-drop • PFM Models

  26. PC-based solutions • Requires S/W to PLC • Requires S/W to display • Requires S/W to integrate • Located away from factory floor • Competitive Method

  27. Direct I/O solution • Connects to sensors or PLC outputs • Calculates results automatically • Can’t display any other message • Competitive Method - continued

  28. Display anything a G3 can • Require DSP, G3, or MC • Connects to any PLC • Calculate results • Display any message • Send alarm / event notices • Red Lion Method

  29. Protocol conversion • Data collection • Web server • Remote access • Red Lion Solution

  30. Indication Products

  31. Indication Position Price PAX PAX Lite CUB5 CUB4 CUB7 CUB3 Performance

  32. Measure and display volts / amps • Measure and display temperature • Measure and display strain gauges • Count, time, and rate • Add outputs for set-point control • Ideal for small control applications • What do Panel Meters do?

  33. Local display for machine operators • Local operator adjustments • Sensor conversion • Redundant systems • Small machine builders w/ small budgets • Where are meters used?

  34. Multiple Sizes 2.95" x 1.5" (75 x 38 mm) 3.80" x 1.95" (97 x 50 mm) PAX Lite series CUB5 series 3.80" x 1.95" (97 x 50 mm) 26" x 7.87" (660 x 200 mm) PAX series LD series

  35. PRS/PRA – Released 1977(??) • CUB1 – Released 1980 • CUB3 – Released 1983 • Apollo Series – Released 1985 • Gemini Series – Released 1985 • IM Series – Released 1988 • Red Lion Stability…

  36. Widely recognized Since 2001 Red Lion panel meters have been voted #1 by Control Design readers.

  37. CUB5 Series – Small Size – Full Feature CUB5

  38. Compact size • Complete product range • Includes Crimson S/W • Display color change at setpoints • Easy USB connection • Custom units indication (analog only) • CUB5 Series

  39. Large .46" display • Reflective and backlight • DC powered • Min/max display capture • UL listed, UL508 • No competition • CUB5 Series - continued

  40. Front panel • Use Crimson S/W • USB • Serial • Easy to program

  41. Reflective, LED, green / red • Up to 2 field replaceable cards • RS-232 • RS-485 • Single relay output (1 Amp) • Dual Sink OC output USB (programming) • The only meter you’ll need CUB5

  42. PAX series – unmatched features

  43. Includes Crimson S/W • AC or DC powered versions • Complete product range • Retransmitted analog output • Unit label kits • PAX Series

  44. Bright .56" LED red / green display • Variable intensity display • Programmable key & user inputs • Display flashing alarm condition • UL listed 508, CE tested • NEMA 4X/IP65 • PAX series - continued

  45. Up to 3 field replaceable cards • RS-232 RS-485 • DeviceNet Profibus • Modbus • Dual relay output • Quad relay output • Analog out • USB (programming) • Unmatched by competition • PAX series - continued

  46. Check out these displays… Sunlight readable RED display Standard GREEN display

  47. Digital Models PAXI Timer/Real Time Clock Count PAXCK Rate PAXR

  48. Analog Models Voltage Current Temperature PAXD PAXT PAXH PAXS PAXP Strain Gage Process

  49. PAX Lite Series – Basic Needs

  50. Includes Crimson S/W • Ideal for the OEM market • Field replaceable cards are not needed • Bright .56” display • Universal AC power 85 – 250VAC • Some units have dual outputs • PAX Lite Series