1 / 27

OPERATOR, Tester & INSTALLER Licensing WWQRR, Chapter 17, Part L

OPERATOR, Tester & INSTALLER Licensing WWQRR, Chapter 17, Part L. OPERATORS. Class A Class B Class C WWQRR, Chapter 17, Section 46 Page 17-100. All facilities. Must have designated operators May not hire a contractor to be the licensed operator. Class A Operator.

anja
Télécharger la présentation

OPERATOR, Tester & INSTALLER Licensing WWQRR, Chapter 17, Part L

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. OPERATOR, Tester & INSTALLER LicensingWWQRR, Chapter 17, Part L

  2. OPERATORS • Class A • Class B • Class C WWQRR, Chapter 17, Section 46 Page 17-100

  3. All facilities • Must have designated operators • May not hire a contractor to be the licensed operator

  4. Class A Operator WWQRR, Chapter 17, Section 46(a) Page 17-100 • Must Pass ICC W-6 Exam • Generally the area manager with multiple locations Five Years

  5. Class B Operator • Has to pass the ICC National U-B Exam • DEQ may accept another state’s ICC exam however the license expires after two years (other states once you pass you never have to take it again). • If it is an AST facility may take the W-5 exam • Defined as the person in responsible charge Five years unless a Notice of Violation with Order is issued and then they have to take the ICC W-6 within 90 days

  6. Class C Operator • The managers and fuel clerks who are not in responsible charge of the location • Must be trained by the Class A or B operator for that location • They must be trained onsite • Records of Class C operator training must be kept onsite.

  7. Class C Operator Training • Proper procedures to follow when the dispensers or any other part of the system are damaged • Location of emergency switches • Limits of maintenance • What to do when fuel is released • What records have to be kept • Delivery procedures and hazards • Alarm recognition • Location and function of all leak detection and CP devices and systems

  8. Unattended Stations • The Class A,B or C operator must visit the site daily • Fire Code already requires daily visits.

  9. Monthly Inspections • If the Class A operator is over more than one facility • Conducted by the Class A or B operator that is designated for that facility • Must be documented • Emergency power generators are now exempted

  10. Monthly Inspection • Presence of any sensor or alarm condition responding appropriately • Integrity of spill containment (spill buckets) • Condition of single wall piping • Hanging hardware and other visible piping

  11. Quarterly Inspection • If the site has double wall piping and sumps • Clean sumps if necessary • Sump sensors are to be placed within ½” from the bottom of the sump

  12. Quarterly Inspection

  13. CP Testers WWQRR, Chapter 17, Section 47 Page 17-103 • Have to be certified by NACE or STI • Renew every three years

  14. CP Experts • Certified by NACE • Possess a current PE license and have three years experience in the CP field

  15. Installers WWQRR, Chapter 17, Section 45 Page 17-99 • Must pass W-6 exam • Must have current 40 hour HAZWOpER • Must pass ICC AST installation and retrofitting exam if doing AST installs • Must pass ICC UST installation and retrofitting exam if doing UST installs. • If they do any maintenance or repairs to anything underneath the fire valve. • Three years

  16. Tank and Line Testers WWQRR, Chapter 17, Section 48 Page 17-104 • Must pass ICC U-3 Exam • Must have current manufacturers training certification for type of tank or line testing performed • Two years

  17. Revocation WWQRR, Chapter 17, Section 49 • Submission of falsified data • False reporting • License revoked (ICC, NACE, PE Board Etc)

  18. Questions Who is responsible to train the Class C operator? • The DEQ • The company training officer • The Class A or B Operator designated for the site • An independent third party training company WWQRR, Chapter 17, Section 46(h) Page 101

  19. Questions What is the maximum number of facilities a Class B operator can be in responsible charge of? • 10 • 15 • 20 • There is no limit WWQRR, Chapter 17, Section 46(b) Page 100

  20. Questions What is the maximum number of facilities a Class A operator can be in responsible charge of? • 10 • 15 • 20 • There is no limit WWQRR, Chapter 17, Section 46(a) Page 100

  21. Questions Given: A gas station has a Class A Operator that is in charge of 5 facilities. Question: How often do the double wall piping sumps have to be inspected by the Class A or B Operator for that facility? • Monthly • Every 60 days • Quarterly • Annually WWQRR, Chapter 17, Section 46(d)(ii) Page 101

  22. Questions Which of the following organization’s certification is acceptable for CP testers? • API (American Petroleum Institute) • ICC (International Code Council) • STI (Steel Tank Institute) • PEI (Petroleum Equipment Institute) WWQRR, Chapter 17, Section 47(a)(ii) Page 103

  23. Questions What of the following certifications is not required to become licensed as a tank installer/retrofitter? • API 650 Certification • 40 Hour HAZWOpER • ICC W-6 Operator’s Exam • ICC Installation/Retrofitting exam WWQRR, Chapter 17, Section 45(a)(i) Page 99

  24. Questions Within how many days of first date of employment must an operator obtain a license from the department? • Within 30 days • Within 60 days • Within 90 days • Within 6 months WWQRR, Chapter 17, Section 46(c) Page 100

  25. Questions Within how many days must the owner/operator of a facility notify the department that a licensed operator is no longer responsible for a facility? • Within 7 days • Within 30 days • Within 90 days • Within 6 months WWQRR, Chapter 17, Section 46(n) Page 103

  26. Questions Within how many days must the Class B operator for a facility take the ICC W-6 Exam if a Notice of Violation and Order has been issued for the reasons issued in the Delivery Prohibition section? • Within 7 days • Within 30 days • Within 90 days • Within 6 months WWQRR, Chapter 17, Section 46(m) Page 103

More Related