1 / 57

Electroanalytical Chemistry

Electroanalytical Chemistry. Lecture #2. An Interfacial Process. For: O + ne - = R 5 separate events must occur: O must be successfully transported from bulk solution (mass transport) O must adsorb transiently onto electrode surface (non-faradaic)

Télécharger la présentation

Electroanalytical Chemistry

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Electroanalytical Chemistry Lecture #2

  2. An Interfacial Process • For: O + ne- = R • 5 separate events must occur: • O must be successfully transported from bulk solution (mass transport) • O must adsorb transiently onto electrode surface (non-faradaic) • CT must occur between electrode and O (faradaic) • R must desorb from electrode surface (non-faradaic) • R must be transported away from electrode surface back into bulk solution (mass transport)

  3. What is an Electrode? • Electrical double layer

  4. Electrode Classification • Based on the nature and number of phases between which electron transfer occurs • 3 Classes: • Electrodes of the First Kind • Electrodes of the Second Kind • Electrodes of the Third Kind

  5. Electrode of the First Kind • Metal in contact with its cations or non-metal in contact with its anions • EXAMPLES: • Cu2+ /Cu(s) • Zn2+/Zn(s) • SHE • Ag+/Ag (nonaqueous reference electrode) • Cl-/Cl2(g)/Pt Electrodes in Daniell cell

  6. Electrode of the First Kind (cont’d) • Electrode response given by Nernst equation (Nernstian): • E = E0 + (RT/nF) ln a(M2+) • NOTE: Fe, Al, and W electrodes are NOT electrodes of the First Kind • these have relatively thick surface oxide coatings

  7. Electrode of the Second Kind • Metal in contact with sparingly soluble salt of the metal • Common name: anion electrodes • EXAMPLES: • Ag/AgCl(s) • Hg/Hg2Cl2(s)/Cl- (saturated calomel electrode; SCE)

  8. Electrode of the Second Kind • Electrode response given by: • E = E0 - (RT/F) ln a(Cl-) • NOTES: • anion activity determines potential • make great reference electrodes because of low solubility of salt (potential very stable)

  9. The Calomel Reference Electrode Note: concentrations typically high  concentrations small  electrode doesn’t become polarized  potential constant

  10. Electrode of the Third Kind • Electrodes that merely serve as sources or sinks for electrons • Common names: redox, inert, unattackable • EXAMPLES: • metals: Pt, Au, GC, graphite, HOPG, Hg • semiconductors: Si, GaAs, In-SnO2/glass • Response: • for Pt in contact with Fe2+, Fe3+ in solution: • E = E0- 0.059 (V) log ([Fe2+]/[Fe3+])

  11. Electrode of the Fourth Kind • Electrodes that cannot be classified as 1-3 • EXAMPLES: • Chemically modified electrodes (CME’s)

  12. Reference Electrodes • Purpose: provide stable potential against which other potentials can be reliably measured • Criteria: • stable (time, temperature) • reproducible (you, me) • potential shouldn’t be altered by passage of small current = not polarizable • easily constructed • convenient for use

  13. Advantages International standard E0 0 V One of most reproducible potentials + 1 mV Disadvantages Convenience Pt black easily poisoned by organics, sulfide, cyanide, etc. Hydrogen explosive Sulfuric and hydrochloric strong acids SHE

  14. Aqueous SCE Ag/AgCl Nonaqueous Ag+/Ag pseudoreferences Pt, Ag wires Ferrocene Practical Reference Electrodes

  15. Cl-(aq)/Hg2Cl2/Hg(l) Hg22+ + 2e- = 2Hg(l) E0 = 0.24 V vs. SHE @ 250C Disadvantages Hg toxic solubility of KCl temperature dependent dE/dT = -0.67 mV/K (must quote temperature) SCE Advantages • Most polarographic data ref’d to SCE From BAS www-site: http://www.bioanalytical.com/

  16. Ag wire coated with AgCl(s), immersed in NaCl or KCl solution Ag+ + e- = Ag(s) E0 = 0.22 V vs. SHE @ 250C Disadvantages solubility of KCl/NaCl temperature dependent dE/dT = -0.73 mV/K (must quote temperature) Ag/AgCl Advantages • chemical processing industry has standardized on this electrode • convenient • rugged/durable From BAS www-site: http://www.bioanalytical.com/

  17. Ag+ + e-= Ag(s) requires use of internal potential standard Disadvantages Potential depends on solvent electrolyte (LiCl, TBAClO4, TBAPF6, TBABF4 Care must be taken to minimize junction potentials Ag+/Ag Advantages • Most widely used • Easily prepared • Works well in all aprotic solvents: • THF, CAN, DMSO, DMF From BAS www-site: http://www.bioanalytical.com/

  18. Pseudo-References • Pt or Ag wire (inert) • Idea:in medium of high resistance, low conductivity, wire will assume reasonably steady, highly reproducible potential (+20 mV) • Advantage: no solution contamination • Limitation: must use internal potential standard (ferrocene)

  19. Can Aqueous References Be Used in Nonaqueous Media? • Yes with caution! • May be significant junction potentials • Requires use of internal standard • May be greater noise • Electrolyte may precipitate/clog electrode frit • Don’t forget about your chemistry • Chemistry may be water sensitive

  20. Electrodes • Metal • solid • Pt, Au, Ag, C • liquid • dropping mercury electrode (DME) • Semiconductors • Si, GaAs • In-SnO2/glass (optically transparent)

  21. Carbon • Paste • With nujol (mineral oil) • Glassy carbon (GC) • Amorphous • Pyrolytic graphite - more ordered than GC • Basal Plane • Edge Plane (more conductive)

  22. Electrode Materials • Different Potential Windows • Can affect electron transfer kinetics

  23. Electrodes • Size • Analytical macro • 1.6 - 3 mm diameter • Micro • 10-100 m diameter From BAS www-site: http://www.bioanalytical.com/

  24. Electrode Geometry Geometry is critical and affects how the data are analyzed and interpreted • Disk • area: r2 • wire (cylinder) • area: l(2 r) r2 • Mesh • optically transparent • Sheet Note: Geometric area < effective surface area

  25. Cleanliness IS Next to Godliness in Electrochemistry • Working electrode must be carefully cleaned before each experiment • Mechanical • Abrasion with alumina or “diamond” polish • Chemical • Sonicate in Alconox • Soak in HNO3 • Electrochemical • Cycle in 0.5 M H2SO4 (Pt)

  26. Electrochemical Cleaning Taken from Table 4-7 in Sawyer, D.T.; Roberts, Jr., J.L. Experimental Electrochemistry for Chemists Wiley: New York, 1976.

  27. Counter Electrode • Area must be greater than that of working • Usually long Pt wire (straight or coiled) or Pt mesh (large surface area) • No special care required for counter From BAS www-site: http://www.bioanalytical.com/

  28. Ew = Ecell - iRcell - Epolarization • When is iR large? • I is high, I > 10 A • large electrodes • solvents with low conductivity • relatively polar organic solvents

  29. Two Common Configurations • 2-electrode cell • iR must be small < 1 mV (microelectrodes) • 3-electrode cell • Avoids internal polarization of reference electrode • Compensates for major potion of cell iR drop From BAS www-site: http://www.bioanalytical.com/

  30. 2-Electrode Cell • 2-electrode cell • Working • Reference electrode • Current passed between working and reference

  31. 3-Electrode Cell • 3-electrode cell • Working • Reference • Counter/auxilliary • Current is passed between working and counter • High impedance placed in front of reference (low current) so ref. Potential constant

  32. Potentiostat/Galvanostat • Potentiostat • Control potential • Cyclic voltammetry, chronoamperometry, etc. • Galvanostat • Control current • Potentiometry From BAS www-site: http://www.bioanalytical.com/

  33. Evolution of the Electrode Double Layer Models • Time-Line: • Helmholtz 1879 • Guoy-Chapman 1910-13 • Stern 1924 • Grahame 1947

  34. + + + + _ _ _ _ Helmholtz Model • Interface between electrolyte solution and electrode behaves like a capacitor in its ability to store charge Potential dies off sharply as we move away from electrode solution  electrode Distance from electrode Double Layer

  35. Helmholtz Model • Double charge layer = electrically neutral interface • Defects: • No interactions occur further away from first layer of adsorbed ions • [Electrolyte] - no effect

  36. Guoy-Chapman Model • Idea: Diffuse double layer - Double layer not compact but of variable thickness with ions free to move • Accounts for effects of applied potential and [electrolyte] Potential dies off exponentially as we move away from electrode  Distance from electrode

  37. + + + + + + + _ _ _ _ _ _ _ Stern Model • Combination of Helmholtz and Guoy Chapman models Bulk solution electrode Compact Layer Diffuse Layer

  38. Specifically adsorbed ions are desolvated, approach electrode surface closer, and feel greater potential 3 region model IHP - Inner Helmholtz Plane passes through center of specifically adsorbed ions OHP - Outer Helmholtz Plane passes through solvated and non-specifically adsorbed ions + + + + + + _ _ _ _ _ _ _ Grahame Model Bulk solution electrode IHP OHP

  39. Au/water • Pzc (potential of zero charge) 0.18 V • E negative of pzc  excess negative charge (electrostatic interactions possible) • Normally hydrophobic • has strong affinity for organic contaminants • Clean surface hydrophilic • wettability

  40. Junction Potential • Electrical potential that develops at the interface between two solutions • Since we isolate reference electrode from working by frit 1 or more junction potentials exist in cell Ew = Ecell - Ejunction

  41. Mass Transport • 3 Modes: • Diffusion • Migration • Convection • Natural • Mechanical • Movement of mass described by Nernst-Planck equation

  42. Diffusion • Movement of mass due to a concentration gradient • Occurs whenever there is chemical change at a surface, e.g., O  R

  43. Migration • Movement of a charged species due to a potential gradient • Opposites attract • Mechanism by which charge passes through electrolyte

  44. Convection • Movement of mass due to a natural or mechanical force • at long times ( > 10 s), diffusing ions set up a natural eddy of matter

  45. Movement of Ions in Solution • Can be described in 3 equivalent ways: • Molar ionic conductivity, i (electrochemistry) • Ionic mobility, ui (separations) • Frictional coefficients, fi (industry/engineering)

  46. Molar Ionic Conductivity • So, short and fat better than long and slender • units: S m2/mol Taken from Table 2.3.2 in Bard, A.; Faulkner, L. Electrochemical Methods Wiley: New York, 1980.

  47. Questions • What size conductivities do electrolyte ions have? • How do the cation and anion conductivities compare in electrolytes? Taken from Table 2.3.2 in Bard, A.; Faulkner, L. Electrochemical Methods Wiley: New York, 1980.

  48. Questions • Have we made any assumptions about concentration and ionization? • Will the conductivity of ions be the same in different solvents? Taken from Table 4-7 in Sawyer, D.T.; Roberts, Jr., J.L. Experimental Electrochemistry for Chemists Wiley: New York, 1976.

  49. Molar Ionic Conductivity • at infinite dilution, no interionic interactions, somolar conductivity of salt =  ion molar conductivity

More Related