1 / 36

Chapter 8

Chapter 8. Sensors The Eyes & Ears of the system. Alarms: The First Line of Defense. Perimeter Sensor Objective. To Detect an Event. An Open Door. A Broken Window. Entry Thru Wall, Roof or Floor. Entry Thru Outer Perimeter. Perimeter. The perimeter is the outer reaches of a system.

augustin
Télécharger la présentation

Chapter 8

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chapter 8 Sensors The Eyes & Ears of the system Alarms: The First Line of Defense © 2001 National Burglar & Fire Alarm Association 8-1

  2. Perimeter Sensor Objective • To Detect an Event. • An Open Door. • A Broken Window. • Entry Thru Wall, Roof or Floor. • Entry Thru Outer Perimeter. © 2001 National Burglar & Fire Alarm Association 8-2

  3. Perimeter • The perimeter is the outer reaches of a system. • For a building system it is the walls, floor and ceiling. • For an outdoor system it is a fence or perhaps the outer edge of the sensors pattern. © 2001 National Burglar & Fire Alarm Association 8-3

  4. Magnet Magnet Magnetic Reed Switch Switch changes with magnet away from switch. Contacts are enclosed In hermetically sealed tube. © 2001 National Burglar & Fire Alarm Association 8-4

  5. Mechanical Switches • Simple & inexpensive. • Easily defeated. • Subject to corrosion. © 2001 National Burglar & Fire Alarm Association 8-5

  6. Door & Window Switch False Alarms • Doors & windows must be tight fitting & locked. • Door & window contacts must be free of paint & varnish. • Make sure there is no door or window warping. • Any broken contacts should be replaced immediately. © 2001 National Burglar & Fire Alarm Association 8-6

  7. Foil Patterns 18 ” Plate Glass Tempered Safety Re-inforced or Sun Film Coated Multi-pane © 2001 National Burglar & Fire Alarm Association 8-7

  8. Foil False Alarms • Foil contains lead & needs to be replaced every 3-5 years due to extreme summer weather. • It can be easily scratched or damaged. • Scratched or damaged foil can cause false alarms. © 2001 National Burglar & Fire Alarm Association 8-8

  9. Shock or Vibration Detectors • Vibration causes contacts to open. • Tension on contacts is adjustable. • Contact opening may be too fast. © 2001 National Burglar & Fire Alarm Association 8-9

  10. Mercury Devices Closed • Vibration of mercury sealed in tube causes an alarm. • Sensitivity adjusted by varying tube angle. Open © 2001 National Burglar & Fire Alarm Association 8-10

  11. Piezo Electric Devices • Small crystal vibrates to produce electricity when glass is broken • Can be self contained or be wired to a processor. © 2001 National Burglar & Fire Alarm Association 8-11

  12. Shock Sensors Impact • Use simple sensors connected to processors that decide when to initiate an alarm. At Rest © 2001 National Burglar & Fire Alarm Association 8-12

  13. Screens • Screen is laced with thin wire. • Alarm circuit is run through the wiring. © 2001 National Burglar & Fire Alarm Association 8-13

  14. Interior Sensors • Combination Motion Sensors • Ultrasonic Detectors • Microwave Detectors • Passive Infrared Detectors • Photoelectric Detectors • Audio Processors © 2001 National Burglar & Fire Alarm Association 8-14

  15. Motion or Space Detection What changes occur when people move? The detector must respond! © 2001 National Burglar & Fire Alarm Association 8-15

  16. Avoid False Alarms!! • What changes occur when there are no people present or moving? • Detector must NOT respond! © 2001 National Burglar & Fire Alarm Association 8-16

  17. Disguised Sensors Various types of sensors can be concealed or disguised as: 1. Duplex Electrical Outlets. 2. Thermostats. 3. Speaker Grills. 4. Smoke Detectors. 5. Light Fixtures. © 2001 National Burglar & Fire Alarm Association 8-17

  18. Trap Channel Spot Volumetric Motion Sensor Uses © 2001 National Burglar & Fire Alarm Association 8-18

  19. Older Motion Sensors • Ultrasonic • Listens to reflected sound, & responds to a change from movement. • Microwave • Monitors for a reduction in level of transmitted energy which may be caused by motion. • Photoelectric • Responds to an interruption the light beam sent between a transmitter & receiver. © 2001 National Burglar & Fire Alarm Association 8-19

  20. Passive Infrared Responds to changes of infrared energy levels within specific fields of view. © 2001 National Burglar & Fire Alarm Association 8-20

  21. Poor or No Catch Gradual Change Motion + 0 © 2001 National Burglar & Fire Alarm Association 8-21

  22. Good Catch Rapid Change Motion + 0 © 2001 National Burglar & Fire Alarm Association 8-22

  23. PIR Patterns Pet Alley Think! Pets climb, jump, & go places they shouldn’t. If a pet can cause a false alarm assume it will. © 2001 National Burglar & Fire Alarm Association 8-23

  24. Microwave PIR Dual Technology Sensors Overlapping patterns of the two technologies provide stability preventing false alarms in harsh environments. © 2001 National Burglar & Fire Alarm Association 8-24

  25. What Can Cause Motion Detector False Alarms? • helium balloons (especially mylar) • pets • bugs on the lens • curtains All interior equipment should be dusted, vacuumed around, etc for bugs & spiders. © 2001 National Burglar & Fire Alarm Association 8-25

  26. Glassbreak Sensors Audio discriminators listen for the sounds of forced entry; • Glass Breakage • Splintering Wood • Etc. © 2001 National Burglar & Fire Alarm Association 8-26

  27. Glass Break Sensor False Alarm Sources • Single technology glass break sensors can mistake the following for glass breaking: • Clinking glasses • Strong or heavy vibrations • Pots & pans hitting each other • Other sounds similar to the sound of glass breaking • USE DUAL TECHNOLOGY SENSORS! © 2001 National Burglar & Fire Alarm Association 8-27

  28. Pressure Mats Mounted under carpet in area likely to be walked upon. Pressure on the mat shorts the metal strips together. © 2001 National Burglar & Fire Alarm Association 8-28

  29. Stress Sensors Mount under joists in area to be covered. © 2001 National Burglar & Fire Alarm Association 8-29

  30. Mats & Stress Sensor False Alarm Sources Both are stable until furniture is rearranged around or on top of them © 2001 National Burglar & Fire Alarm Association 8-30

  31. Manual Devices • Foot rail. • Holdup button. • Money clip. • Portable duress sensor. • Touchpad Activated © 2001 National Burglar & Fire Alarm Association 8-31

  32. Manual DevicesFalse Alarm Sources • Improper user training • ”Single action" buttons • “Single action” money clips • Batteries in wireless buttons that are not replaced when the manufacturer recommends. © 2001 National Burglar & Fire Alarm Association 8-32

  33. Fire Alarm Sensors • Smoke Detectors. • Heat Detectors. • Flame Detectors. • Manual Pull Stations. © 2001 National Burglar & Fire Alarm Association 8-33

  34. Condition Monitoring • Alarms Can Be Used to Monitor: • Medical Emergencies. • Low or High Temperature. • Failure of Equipment. • Operation of Equipment. • (Generators, Sump Pumps , Etc..) • Water or Moisture • Power Failure © 2001 National Burglar & Fire Alarm Association 8-34

  35. Carbon Monoxide Gas Alarms • Indicates an unacceptable level of carbon monoxide gas is present in a room. • May indicate a failure in a furnace or improper ventilation in a room with a fireplace or wood stove. • Even limited exposure to high levels of carbon monoxide can be lethal to humans and animals. © 2001 National Burglar & Fire Alarm Association 8-35

  36. 1- Introduction 2- What is an Alarm System 3- What is A False Dispatch 4- Impact of False Dispatches 5- Causes of False Dispatches 6- Preventing False Dispatches 7- User Controls 8- Sensors 9- The Control 10- The Central Station 11- How Authorities Respond 12- What to expect for Alarm Co.s 13- The Alarm Ordinance 14- Sources of Information 15- Site Survey Alarms: The First Line of Defense Next Chapter 5 Minute Break 10 Minute Break 30 Minute Lunch 60 Minute Lunch © 2001 National Burglar & Fire Alarm Association 8-36

More Related