ME- 495 Mechanical and Thermal Systems Lab Fall 2011

ME- 495 Mechanical and Thermal Systems Lab Fall 2011. Chapter 5: MEASURING SYSTEM RESPONSE Professor: Sam Kassegne, PhD, PE. Signal. Response of Measurand?. RESPONSE.

axelle
Télécharger la présentation

ME- 495 Mechanical and Thermal Systems Lab Fall 2011

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ME- 495Mechanical and Thermal Systems LabFall 2011 Chapter 5: MEASURING SYSTEM RESPONSE Professor: Sam Kassegne, PhD, PE

  2. Signal Response of Measurand?

  3. RESPONSE • System Response: an evaluation of the systems ability to faithfully sense, transmit and present all pertinent information included in the measurand and exclude all else: • Key response characteristics/components are: • Amplitude response • Frequency response • Phase response • Slew Rate

  4. COMPONENTS OF SYSTEM RESPONSE 1) Amplitude response: • ability to treat all input amplitudes uniformly • Overdriving – exceeding an amplifiers ability to maintain consistent proportional output • Gain = Amplification = So/Si • Smin<Si<Smax Overloaded in this range.

  5. COMPONENTS OF SYSTEM RESPONSE 2) Frequency Response • ability to measure all frequency components proportionally • Attenuation: loss of signal frequencies over a specific range Attenuated in this range.

  6. COMPONENTS OF SYSTEM RESPONSE 3) Phase Response • amplifiers ability to maintain the phase relationships in a complex wave. • This is usually important for complex waves unlike amplitude and frequency responses which are important for all types of input wave forms. Why?

  7. COMPONENTS OF SYSTEM RESPONSE • 4) Delay/Rise time: time delay between start of step but before proper output magnitude is reached. • Slew rate: maximum rate of change that the system can handle (de/dt) (i.e. for example 25 volts/microsecond)

  8. Dynamic Characteristics of Simplified Mechanical Systems Generalized Equation of Motion for a Spring Mass Damper System(1-axis) • F(t) = general excitation force •  = fundamental circular forcing frequency

  9. FIRST ORDER SYSTEM(I.A) Step Forced If mass = 0, we get a first-order system. E.g. Temperature sensing systems • F(t)=0 for t<0 • F(t) = F0 for t >= 0 • t=time, k=deflection constant • s=displacement, =damping coefficient • Fo=amplitude of input force • This can be reduced to the general form: (after integration over time and simplification) • P=magnitude of any first order system at time t • P=limiting magnitude of the process as t  • PA=initial magnitude of process at t=0 •  = time constant = /k The above equation could be used to define processes such as a heated/cooled bulk or mass, such as temperature sensor subjected to a step-temperature change, simple capacitive-resistive or inductive-resistive circuits, and the decay of a radioactive source.

  10. Figure (a) depicts progressive process Figure (b) depicts decaying process

  11. FIRST ORDER SYSTEM(I.B) Harmonically Excited F(t) = Fo cosWt

  12. PHASE LAG

  13. First Order System – Harmonically Excited – ExampleTemperature Probe Example

  14. TEMPERATURE PROBE EXAMPLE - Continued

  15. TEMPERATURE PROBE EXAMPLE - Continued

  16. (II) SECOND ORDER SYSTEM(II.A) Step Input • Step input • F=0 when t<0 • F=Fo when t>0 • Underdamped Eq:

  17. OVERDAMPED SECOND ORDER SYSTEM • =  / C >1 This represents both damped and under-damped cases.

  18. (II) SECOND ORDER SYSTEM(II.B) Harmonically Excited F(t) = Fo cosWt

  19. MICROPHONE EXAMPLE Second Order System – Harmonically Excited ExampleMicrophone Example

  20. MICROPHONE EXAMPLE