Two op amp measurement loop

Two op amp measurement loop. Power Supply Rejection Ratio. PSRR test part 1 of 2. PSRR = ΔV OS / ΔV S. Min Supply. 999 R1. R1. +1.85V. DUT. -. +. V OS. A2. 1000·V OS. -0.85V. Power Supply Rejection Ratio. PSRR test part 2 of 2. Max Supply. PSRR = ΔV OS / ΔV S. +3.25V.

Télécharger la présentation

Two op amp measurement loop

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Two op amp measurement loop

  2. Power Supply Rejection Ratio PSRR test part 1 of 2 PSRR = ΔVOS / ΔVS Min Supply 999 R1 R1 +1.85V DUT - + VOS A2 1000·VOS -0.85V

  3. Power Supply Rejection Ratio PSRR test part 2 of 2 Max Supply PSRR = ΔVOS / ΔVS +3.25V 999 R1 R1 DUT - + VOS A2 1000·VOS -2.25V

  4. Power Supply Rejection Ratio VOS vs. VS “Soft” breakdown at high voltage. VOS(μV) Operation “falling out” at low voltage. 1 2 3 4 5 6 Total Supply Voltage

  5. 120 90 60 30 0 -30 -60 -90 -120 PSRR is slope over end-points. VOS(μV) Max Vs Min Vs Power Supply Rejection Ratio At TA = +25°C, RL = 10kW connected to VS/2 and VOUT = VS/2, unless otherwise noted. PSRR = ΔVOS / ΔVS 1 2 3 4 6 Total Supply Voltage