1 / 10

LO/IF System PDR

LO/IF System PDR. LO/IF Switches Doug Scott. LO/IF System PDR. Type of Switches (# per antenna) IF High Band Switches (4) IF Low Band Switches (4) IF Transfer Switches (2) LO Switches (2). LO/IF System PDR. IF High Band Switch Specifications Frequency Range: 8 to 12 GHz

bourg
Télécharger la présentation

LO/IF System PDR

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LO/IF System PDR LO/IF Switches Doug Scott LO/IF System PDR 22-23 January 02

  2. LO/IF System PDR • Type of Switches (# per antenna) • IF High Band Switches (4) • IF Low Band Switches (4) • IF Transfer Switches (2) • LO Switches (2) LO/IF System PDR 22-23 January 02

  3. LO/IF System PDR • IF High Band Switch Specifications • Frequency Range: 8 to 12 GHz • VSWR: 1.4 to 1 max • Insertion Loss: 0.4 db max • Isolation: 60 db min • # of poles: 1 per switch • # of throws: 9 min per switch LO/IF System PDR 22-23 January 02

  4. LO/IF System PDR • IF Low Band Switch Specifications • Frequency Range: 1 to 8 GHz • VSWR: 1.3 to 1 max • Insertion Loss: 0.4 db max • Isolation: 70 db min • # of poles: 1 per switch • # of throws: 6 min per switch LO/IF System PDR 22-23 January 02

  5. LO/IF System PDR • IF Transfer Switch Specifications • Frequency Range: DC to 12 GHz • VSWR: 1.4 to 1 max • Insertion Loss: 0.4 db max • Isolation: 60 db min • # of poles: 2 per switch • # of throws: 2 min per switch LO/IF System PDR 22-23 January 02

  6. LO/IF System PDR • LO Switch Specifications • Frequency Range: 12 to 20 GHz • VSWR: 1.8 to 1 max • Insertion Loss: 0.8 db max • Isolation: 55 db min • # of poles: 1 per switch • # of throws: 6 min per switch LO/IF System PDR 22-23 January 02

  7. LO/IF System PDR • Mechanical Switches • Better Insertion Loss • Better VSWR & BW • Better Phase & Amplitude Performance • Electronic Pin Diode Switches • Lower Cost • High Reliability LO/IF System PDR 22-23 January 02

  8. Switch Costs IF High Band IF Low Band IF Transfer $1775 (1-2) $965 (1-2) $435 (1-2) $1511(3-5) $821 (3-5) $370 (3-5) $1384 (6-10) $743 (6-10) $328 (6-10) $1162 (51-100) $612 (51-100) $261 (51-100) LO Switches to use recycled FE switches. LO/IF System PDR 22-23 January 02

  9. LO/IF System PDR • LO/IF Switch Physical Locations • IF High Band, Outside B Rack • IF Low Band, Outside B Rack • IF Transfer, Inside B Rack • LO, Outside B Rack • Additional Control Switch Module LO/IF System PDR 22-23 January 02

  10. LO/IF System PDR • Current Status • Obtaining more switch price quotes • Purchase Requisitions signed by 2/02 • Switches available in 6-10 wks LO/IF System PDR 22-23 January 02