An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MAGNETOMETRY Theoretical and experimental research Baltag Octavian Ioan Ligns of force of the geomagnetic field (Glatzmaier et Roberts, 1995). http://paleomag.uqar.ca/spip.php?article44

  2. 1971 B.Sc. in Physics - specialized in Electroradiophysics "Alexandru Ioan Cuza" University of Iasi 1982 Ph.D. with a thesis entitled "Contributions to development of low magnetic fields magnetometers" Central Institute of Physics - Bucuresti

  3. THEORETICAL AND APPLICATIVE RESARCH IN MAGNETOMETRY DIRECTIONS 1971 - 2001 MAGNETOMETRY Space applications Marine applications and naval degaussing Terrestrial – special applications Laboratory – research & industry MAGNETIC DETECTION Magnetic naval and terrestrial mines Industrial applications -buried metallic bodies METROLOGY, TRANSDUCERS & SPECIAL DEVICES PROTECTION OF INTELECTUAL & INDUSTRIAL PROPERTY Patents Trademarks ELECTROMAGNETIC COMPATIBILITY • Special applications • Research & industry

  4. RESEARCH DOMAIN 2001 - 2008 HIGH RESOLUTION MAGNETOMETRY • Biomedical applications MICROWAVE RADIOMETRY • Microwave Thermografy – early detection of the breast cancer

  5. Hex Hex Iex h U2f h + Hex h - Hex h h ferrofluid h Hex Iex U2f h I ex h Iex h U2f MAGNETOMETRY • Theoretical & experimental research on the fluxgate transducers for low magnetic field

  6. B B +Bs H t -Bs d/dt H=H0sint h=0 h>0 t h>0 H U2f t Core I Core II  t Fluxgate diagram

  7. RESULTS AND APPLICATIONS • Research on the fluxgate transducers & magnetometer electronics –applications forIntercosmos satellites • Technical data: • range: +/- 80.000 nT • frequency of pulse excitation: 2 kHz, • second harmonic: 4 kHz • noise: < 1 nT • nonlinearity : < 1% • applications: triaxial magnetometer for Intercosmos satellites

  8. FLUXGATE WITH MULTIPLE PATH OF FLUXpatent RO, nr. 60.346, Int. Cl. G01R33/00 • Fluxgate sensor with multiple path of flux, O. Baltag, D. Costandache„ “Studies in applied electromagnetics and mechanics”, vol.13, pp.337-340, 1998, Editor: V. Kose, J. Sievert, IOS Press- Amsterdam, ISSN: 1383-7281 • Specifications: • Measuring range: +/- 200.000nT • noise: < 1 nT • excitation: pulse • liniarity: < 1% Core: permalloyprocessed by photogravure, trated in hidrogen, coil support: noriland cuartz powder

  9. FLUXGATE WITH MULTIPLE PATH OF FLUXpatent RO, nr. 60.346, Int. Cl. G01R33/00

  10. NONLINEAR RESONANCE PHENOMENA IN FLUXGATE Fluxgate transfer characteristic in nonlinear resonance regime • Specific phenomena: • In certain operation conditions the fluxgate transducer no longer works as a magnetic field sensor and it is generating an almost quasisinusoidal signal with a frequency equal to the odd or even harmonics of the excitation signal • The second harmonic phase can only be changed (with 180°) by applying a continuous or alternative magnetic field exceeding the threshold value characteristic to the regime.

  11. Fluxgate – nonlinear resonance Transfer characteristic U2ω = f (h) of the fluxgate in second harmonic resonance regime U2f second harmonic amplitude H external magnetic field Uex excitation voltage f excitation frequency • Hysteresis response to applied field of the fluxgate on second harmonic: • UQ second harmonic quadrature component • US second harmonic, sinphasic component • UA second harmonic amplitude • H external magnetic field

  12. Nonlinear resonance - Applications • Double pumping magnetometer and measuring method, patent Ro, No. 67520, Int. Cl. G01R33/02 • Functional instability of ferromagnetic sensor in nonlinear resonance regime, digest, INTERMAG 96, Seattle, 1996 • Pecularities of the fluxgate responses in the parametric resonance regime, O. Baltag, D. Costandache, Sensors Letters, Vol. 7, No.3, pp. 276–277 (2009) Excitation frequency f=2000Hz: first pumping frequency External magnetic field frequency F=200Hz: second pumping frequency

  13. DOUBLE PUMPING MAGNETOMETERPatent RO, no. 67520, Int. Cl. G01R33/02 Fluxgate responses U2f (second harmonic 2f) at second pumping field F=200Hz, and measuring field Ho Second harmonic U2f of the fluxgate modulated in amplitude by second pumping field with frequency F=200Hz • Functional characteristics: • first pumping frequency(fluxgate excitation): f=2 kHz • second pumping frequency: F=200 Hz • noise: < 0,1 nT • measuring range: +/- 200.000 nT

  14. FERROFLUID FLUXGATE TRANSDUCER • Behaviour of some nonlinear devices with ferrofluid, O. Baltag, D. Costandache, C. Cotae, JMMM, vol. 157 , pp. 591,1996 • Magnetometer with ferrofluid sensor, Baltag O., D.Costandache, IEEE Instrumentation & Measurement Technology Conference IMTC 96, Brussels, 1996, pp.263-265, ISBN: 0-7803-3312-8, IEEE Xplore, INSPEC Number: 5391810 • Sensor with ferrofluid for magnetic measurements, O. Baltag, D. Costandache, IEEE Trans. on Instrumentation and Measurement, vol. 46, nr.2, pp. 629-631, 1997 • Nonlinear behaviour of the ferrofluid in orthogonal magnetic fields, O. Baltag, D. Costandache, JMMM, 201, pp.123-125, 1999 • The study of a magnetic fluid based sensor, C. Cotae, O. Baltag, R.Olaru, D.Calarasu, D.Costandache, JMMM, 201, pp.393-397, 1999 • Sensor with ferrofluid for magnetic measurements, O. Baltag, D. Costandache, Conference on Precision Electromagnetic Measurements, Braunschweigh, June 1996, CPEM-96, pp.61-62, ISBN: 0-7803-3376-4

  15. FERRITE FLUXGATE • Gaussmeter, O.Baltag, D. Costandache, IEEE Proceedings of the International Symposium on Signal, Circuits & Systems, Iasi 1995, pp. 473 • Magnetic field measurement with soft ferrite cored sensors, Baltag O., D. Costandache, 7-th, International Conference on Ferrites, Bordeaux,1996 • Toroidal Fluxgate Sensor Compared in Dynamic Preisach Framework, Salceanu A., Baltag O., Costandache D., The 7-th European Magnetic Materials and Applications Conference, EMMA ‚98, Zaragoza, Spain, pp. 248

  16. AMORPHOUS AND NANOCHRISTALINE FLUXGATE • Preisach approach for modelling an amorphous toroidal fluxgate sensor, A. Salceanu, O. Baltag, D.Costandache, Sensor and Actuators, A, vol. 81, pp.207-211, 1999, ISSN: 0925-4005 • Study of a magnetic field sensor with nanocrystalline materials, Salceanu A., Baltag O., et all, Bul.Inst.Politehnic Iaşi, Tom XLV (IL), Fasc.5A, pp.381-384, 1999, ISSN 0258-9109 • Fluxgate sensor with nanocrystaline ferromagnetic core, Baltag O., M.Craus, D. Costandache, "43 Internationales Wissenschaftliches Kolloquium", Ilmenau , sept. 1998 • Study of a ferrite sensor for medium magnetic field intensity measurement, O. Baltag, D. Costandache, A. Salceanu, Studies in applied electromagnetics and mechanics, in „Studies in Applied Electromagnetics and Mechanics”, vol.18, Editori: P.di Barba, A. Savini, pp.665-669, 2000, IOS Press-Amsterdam, ISSN: 1383-7281

  17. ELECTRONIC CIRCUITS FOR FLUXGATE MAGNETOMETER Electronic devices for fluxgate excitation and generating of reference signal,Patent RO., No. 80140 (1982), Int. Cl. G01G33/02

  18. Reference 2f  Negative feedback circuit Us D.C. Amplifier h Ue Excitation Generator S  Excitation generator Ur = Ue Selective amplifier Phase shift Synchro-nous Detector ir Ur hr Fluxgate f Feedback coil Ku , Ki , rr Frequency divider 1/2 Generator 2f Reference 2f ELECTRONIC CIRCUITS FOR FLUXGATE MAGNETOMETER • Negative feedback network

  19. ELECTRONIC CIRCUITS FOR FLUXGATE MAGNETOMETER Integrated hybrids circuits for magnetometry - ceramics support - resistors – laser trimming - active components: integrated circuits - packaging – epoxy resins and quartz powder