1 / 24

Higher order Laguerre-Gauss modes in future gravitational wave detectors

Higher order Laguerre-Gauss modes in future gravitational wave detectors. S. Chelkowski University of Birmingham 25.09.2008 LSC Meeting, Amsterdam. Overview . Motivation for using Higher-Order Laguerre modes Summary of length and alignment sensing with higher order Laguerre-Gauss modes

connie
Télécharger la présentation

Higher order Laguerre-Gauss modes in future gravitational wave detectors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Higher order Laguerre-Gauss modes in future gravitational wave detectors S. Chelkowski University of Birmingham 25.09.2008 LSC Meeting, Amsterdam LSC Meeting, Amsterdam 09/2008

  2. Overview • Motivation for using Higher-Order Laguerre modes • Summary of length and alignment sensing with higher order Laguerre-Gauss modes • Arm cavity mirror radii of curvature trade-off analysis • Using advanced Virgo as an example • Use inspiral ranges as figure of merit • Three scenarios lead to four different comparisons of the fundamental LG00 and the proposed LG33 mode LSC Meeting, Amsterdam 09/2008

  3. Thermal noise in future GW detectors Advanced Virgo Conceptual Design VIR–042A–07 LSC Meeting, Amsterdam 09/2008

  4. Integrated beam power for modes with 1ppm loss on a mirror with d =35cm by M. Laval and J.-Y. Vinet LSC Meeting, Amsterdam 09/2008

  5. Thermal noise of LG and Flat beams LGnm modes: Flat beams: HG00 mode: Bondu et al. Physics Letters A 246 (1998) 227 Bondu et al. Physics Letters A 246 (1998) 227 J.-Y. Vinet CQG 22 (2005) 1395 formulas valid for infinite media only LSC Meeting, Amsterdam 09/2008

  6. TN scaling factors of LGnm modes n 0 1 5 2 3 4 m 1 0.69 0.57 LG33 0 0.60 0.50 0.44 1 0.46 0.41 0.37 2 LG55 0.31 3 0.27 4 0.25 5 personal communication J.-Y. Vinet numbers shown are for an infinite mirror size LSC Meeting, Amsterdam 09/2008

  7. Expected thermal noise improvements All values given for beam sizes corresponding to 1ppm clipping losses References: C. TN: personal communication J.-Y. Vinet S. TN: Mourset al. . CQG 23 (2006),5777 T. E. N: personal communication J.-Y. Vinet LSC Meeting, Amsterdam 09/2008

  8. Comparison of LG and Flat beams • Spherical phase fronts • Compatible with current interferometers • Beam shape and phase fronts change on propagation • Mirror surfaces are more complex L=3km L=3km Etr Etr Ecav Ecav E0 E0 By M. Laval and J.-Y. Vinet Eref Eref M1 M2 M1 M2 Flat top beam cavity design HG & LG mode cavity design LSC Meeting, Amsterdam 09/2008

  9. Comparison of length and alignment signals for a single cavity LG00 5.0º 1mrad LG33 0.4º for more details see my Elba talk about higher order LG modes LSC Meeting, Amsterdam 09/2008

  10. Clipping loss comparison LSC Meeting, Amsterdam 09/2008

  11. Arm cavity mirror radii of curvature trade-off analysis Simulation parameters: • Bench version 4.1 • Latest IFO model of Adv.Virgo • Rescaled beam size for LG modes • Used thermal noise scaling factor by J-.Y. Vinet • Thermo-elastic TN compensation included • Coating radius 17cm according to Virgo note VIR-038A-08 (2008) Figure of merit: Inspiral ranges LSC Meeting, Amsterdam 09/2008

  12. Advanced Virgo sensitivity LSC Meeting, Amsterdam 09/2008

  13. Three Scenarios • We buy one a set of optimized mirrors for each mode configuration; same clipping losses • We buy mirrors which are compatible with both mode configurations; same radii of curvature • We buy mirrors optimized for the LG00 mode and use the TCS system to optimize them later for LG33 and vice versa LSC Meeting, Amsterdam 09/2008

  14. Scenario 1: Same clipping losses Reference configuration Problem: The mirrors are not compatible! 17% 25% 27% 23% 24% 32% LSC Meeting, Amsterdam 09/2008

  15. Scenario 2: Same radii of curvature • Trade-off concerning clipping loss • LG00 configuration much worse than current baseline Not a good option! -21% 21% -24% 32% -24% 28% Problem: LSC Meeting, Amsterdam 09/2008

  16. Scenario 3: Use thermal compensation system to the change RoC Credit to S. Hild LSC Meeting, Amsterdam 09/2008

  17. Scenario 3a: Use thermal compensation system to the change RoC Advanced LIGO TCS TCS range of 120m LSC Meeting, Amsterdam 09/2008

  18. Scenario 3a: Change RoC with TCS, optimisation for fundamental mode Problem: Implementation of such TCS might be difficult Looks promising! 0% 21% 0% 32% 0% 29% LSC Meeting, Amsterdam 09/2008

  19. Scenario 3b: Use thermal compensation system to the change RoC Advanced LIGO TCS TCS range of 120m LSC Meeting, Amsterdam 09/2008

  20. Scenario 3b: Change RoC with TCS, optimisation for LG33 mode Problem: Implementation of such TCS might be difficult Looks promising! -15% 17% -18% 27% -18% 24% LSC Meeting, Amsterdam 09/2008

  21. Conclusion • LG modes reduce the thermal noise in the IFO • LG modes compatible with current IFO designs • Beam parameters are different • RoC have to be matched, or clipping loss are different • Length and alignment signals of LG33better than LG00 for the same mirror sizes • Inspiral ranges of RoC compatible IFO configuration (Scenario two) are low for fundamental LG00 mode • Best solution uses Thermal Compensation System to adapt RoC to the desired mode LSC Meeting, Amsterdam 09/2008

  22. Higher order Laguerre Gauss modes in triangular cavities LSC Meeting, Amsterdam 09/2008

  23. Behaviour of LG modes in triangular cavities • Two possible solutions for this problem • Do not use triangular cavities • Use sinusoidal LG modes • Thermo-elastic noise of sinusoidal LG modes needs to be investigated! For more details see talk by M. Barsuglia Virgo Biweekly Meeting 1/7/2008 LSC Meeting, Amsterdam 09/2008

  24. ConclusionLG modes in triangular cavities • Helical LG modes are not compatible with triangular cavities • Either use sinusoidal LG modes or use modecleaner cavities with an even number of mirrors • Helical and sinusoidal LG modes have the same brownian thermal noise • Thermo-elastic noise of sinusoidal LG modes unknown • should be investigated LSC Meeting, Amsterdam 09/2008

More Related