1 / 14

HCAL analogue readout

HCAL analogue readout. Silicon PhotoMultiplier (SiPM) MEPhI&PULSAR. SiPM. Pixels of the SiPM. Photo-Detectors. The remaining candidate photodetectors: Avalanche photodetector (APD): S8664-55spl , 3x3mm 2 , S8550, 32 pixels of 1.6x1.6mm 2 gain ~ 50-100

conroy
Télécharger la présentation

HCAL analogue readout

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HCAL analogue readout Erika Garutti

  2. Silicon PhotoMultiplier (SiPM) MEPhI&PULSAR SiPM Pixels of the SiPM Photo-Detectors The remaining candidate photodetectors: Avalanche photodetector (APD): S8664-55spl, 3x3mm2, S8550, 32 pixels of 1.6x1.6mm2 gain ~ 50-100 quantum eff. 81% Silicon photomultiplier (SiPM): sizes: 1x1mm2, 576 and 1000 pixels/mm2 gain ~ 2*106 quantum eff. ~ 15-20% Needed for MINICAL: - 36 Photodetectors APDs combine 3-7 tiles in one cell - 117 SiPM’s of 1x1mm2 - 3 MA-PM –16 channels Erika Garutti

  3. Principle of operation • ADP operated with avalanche • multiplication ~ 50-500 • SiPM operated in Geiger mode • avalanche multiplication ~2*106 • R = 400 k prevents detector break down Erika Garutti

  4. Avalanched Photo-Detectors (APD) • Hamamatsu, 3x3mm APD, S8664-55spl • Delivery time takes 1.5 months for 30 pcs • typical performance: • gain 50 100 >1000 possible • Id 600pA 1.2nA • C 28pF 28pF • Significant gain dependence on voltage and temperature (~10-15%) • Requires good stability of power supply (DV/V=10-4 1% gain stability) • Possibility for a voltage-temperature regulator Erika Garutti

  5. 42m 20m pixel h Resistor Rn=400 k Al R 50 Depletion Region 2 m Substrate Ubias Silicon Photomultiplier (SiPM) R&D at MEPHI (Moscow), B. Dolgoshein, E. Popova together with PULSAR (Russ. Industry) one peak = one photo-el • Some features: • Detector size 1.5x1.5 mm2 • sensitive size 1x1 mm2 • Possibility to couple directly on tile • Number of pixels: 576, now 1000/mm2 • 1 photo-el per pixel  signal shows to Npe • Gain 2106 atUbias~ 50V • Recovery time ~ 100 ns/pixel Erika Garutti

  6. SiPM @ DESY test beam 576 px 60 cm WSL fiber couple 10 pe “conventional” Increase light yield with direct coupling direct coupling 1000 px Directly couple on tile 15 pe Chosen for MINICAL From Elena Podova, MEFhI Erika Garutti

  7. SiPM dark rate and MIP detection efficiency ~ 90%  dark rate ~ 2 Hz efficiency ~ 95%  dark rate ~ 8 Hz Erika Garutti

  8. SiPM energy response MC simulation of SiPM dynamic range impact on hadron energy resolution of TileHCAL Typical particle energy range at TESLA - Saturation at N(pe) ~ N(pixel) - Saturation effect stronger on e than h Erika Garutti

  9. MINICAL readout Assembled with up to 27 scintillator layers of 9 tiles each (5x5X0.5 cm3) 3 layers with diff. photo-detectors: APD’s: 3 tiles/APD 60 cm fiber pre-amp with large gain + good stability ADC MA-PM’s:16fold, 3 tiles/pixel Si-PM’s: 1 tile/Si-PM directly coupled to tile pre-amp with less gain Erika Garutti

  10. The DAQ scheme MINICAL • 120-170 ADC (2249A) channels  controlled via CAMAC • CAMAC-PC interface from MEPHI (KK009) • Changed from MAC to UNIX DAQ • PC in control room @ DESY test beam 21 (10 MBit), 32 GB spaced •  1 run ~ 10k events ~ 4 MB • Use ROOT for analysis of data software under development Erika Garutti

  11. Off-line analysis • scintillators • fibres • photodetectors • pre-amps • e- beam (0.5 –7 GeV) • cosmics • random Flexible set-up allows test of various hardware   in various trigger conditions  At DESY: Start run with new configuration or new settings every 24 hours. via web: ITEP LPI MEPHI Prague Protvino DESY • Look for: • gain • stability • signal width • Signal/noise separation • calibration with MIP’s software-tools (V. Dodolov, E. Garutti, S. Karakash, F. Krivan, E. Popova, A. Terkulov) Erika Garutti

  12. Calibration and monitoring • Cosmic calibration (~1 month, before beam data) : • adjust all ADC channels to same MIP signal • optimisation of pre-amp voltages • LED monitoring triggered between the test-beam pulses : • LED-light distribution by optical fibres to: • all photodetectors  stability monitoring • few stable Si-photodiodes  to monitor the LED light output • (stable against temperature and bias voltage fluctuations) • Established technique from H1 spaCal  precision 1-2% Erika Garutti

  13. Detector understanding Study of energy resolution and cluster shape Compare with MC prediction  tune MC Study various photodetectors against tuned MC Saturation effects in the range 0.5 – 7 GeV  dynamic range  linearity get detector hardware under control !!! Get ready for studies on Physics Prototype … Erika Garutti

  14. Outlook 2004 construction and operation of the Physics Prototype 1 m3 prototype ~ 800-1200 calorimeter cells equipped with: ~ 4000 SiPM + 200-400 APD Tested together with the ECAL prototype •  tune reconstruction algorithm •  study the energy flow concept • detailed understanding of hadronic shower shape (tune GEANT 4) Erika Garutti

More Related