1 / 15

Particle identification — TOF detector of BESIII

Particle identification — TOF detector of BESIII. Heng Yuekun hengyk@mail.ihep.ac.cn. Outline. Functions and target Structure and dimension Detector design TOF+TOF TOF+CCT CCT Experiment plan. Functions of TOF. Particle ID Give a fast trigger (Level-1) Reject cosmic ray background.

curt
Télécharger la présentation

Particle identification — TOF detector of BESIII

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Particle identification—TOF detector of BESIII Heng Yuekun hengyk@mail.ihep.ac.cn

  2. Outline • Functions and target • Structure and dimension • Detector design • TOF+TOF • TOF+CCT • CCT Experiment plan

  3. Functions of TOF • Particle ID • Give a fast trigger (Level-1) • Reject cosmic ray background

  4. PID Target • Time Res.: • Target: • Upper limit of K/ separation(2) : 1.1GeV/c

  5. Detector design • Two layers, two independent time: • Two options: • TOF+TOF • TOF+CCT • PMT connected directly

  6. Dimension • Length: 1906mm • Coverage:~83% • Pieces:80 /layer • Place: • Space: 105mm • Reserved: 7mm • Thickness:49mm /layer

  7. Scintillator:BC404 PMT: R5924 Scintillator and PMT

  8. CCT introduction • Cherenkov Correlated Timing • Proposed in 1994 byK.Honscheid, M.Selen, M.Sivertz • Beam test in 1996 • no detector apply it • need more researches

  9. CCT Principle & advantages • Cherenkov radiation: • Improve PIDGreater mass, Smaller angle,Longer time • Cheap • Simple

  10. TOF+TOF TOF+CCT Comparison of K/ sep.

  11. CCT threshold • Why threshold?Cherenkov radiation& Full reflection: • Under threshold, no signal • TOF layer give trigger signal

  12. CCT Material • Quartz is best,but expensive • Plastic: 50-100ps • BC480:Atte. Length:4.5mCher/Scin.: 10/1

  13. Preliminary Simulation • The Cher. light production and transit in BC480 by Geant4 Fig. Under the different hitting angle, the number of photon received by PMT. Fig. The histogram of the time when the photons hitting the PMT.

  14. T0,Trig. T0,Trig. Scin. Scin. PMT PMT PMT PMT T1 T2 CCT Experiment Plan • Cosmic ray • Lead: • Two Scin.: • Coin. & Trig. • Collimation • Two CCT:T1-T2: Lead Cosmic ray

  15. Summary • Target: 65ps, >1.1GeV • Structure: 2 layers, 2 timing • Two options: • TOF+TOF: experienced • TOF+CCT: better PID, more research • CCT Experiments plan

More Related