1 / 27

Power Grid

Power Grid. A network of power transmission systems Usually more than one path between points on a network. Power Grid. The US and Canadian power companies are integrated into a single power grid Allows backups in case of emergencies, utilities can trade electrical energy and it is economical

cynthiak
Télécharger la présentation

Power Grid

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Power Grid • A network of power transmission systems • Usually more than one path between points on a network

  2. Power Grid • The US and Canadian power companies are integrated into a single power grid • Allows backups in case of emergencies, utilities can trade electrical energy and it is economical • Circuit breakers (devices which cut off the flow of electricity through the circuit protect against sudden surges in power • The can isolate the problem and help the grid reroute the power flow • If the problem is not isolated, the problem can spread throughout major portions of the grid, causing power interruptions we call blackouts.

  3. US Power Grid • Three grids cover the contiguous 48 states and parts of Canada and Mexico and are known as the Western Interconnection, the Eastern Interconnection, and the Electric Reliability Council of Texas (ERCOT) Interconnection. Collectively they make up what is called the national power grid • Each grid may be broken up into smaller power sharing arrangements, described below. • ECAR - East Central Area Reliability Coordination Agreement • ERCOT - Electric Reliability Council of Texas • FRCC - Florida Reliability Coordinating Council • MAAC - Mid-Atlantic Area Council • MAIN - Mid-America Interconnected Network • MAPP - Mid-Continent Area Power Pool • NPCC - Northeast Power Coordinating Council • SERC - Southeastern Electric Reliability Council • SPP - Southwest Power Pool • WSCC - Western Systems Coordinating Council

  4. Power interruptions • Dropouts -momentary (milliseconds to seconds) loss of power typically caused by a temporary fault on a power line. • Brownouts -a drop in voltage in an electrical power supply, so named because it typically causes lights to dim. Can occur if the demand for electricity on the grid is greater than what it can produce • Blackouts - total loss of power to an area • Note that it doesn’t take a bad storm to cause problems with power line. If demand increases and the power on the line increases, the lines heat up and stretch, causing them to sag. If they come in contact with a tree, then the line can short out.

  5. 2003 Blackout • Affected much of the Notheastern US and parts of Canada August 14, 2003. • Timeline: (Thank you Wilkipedia) • # 12:15 p.m. Incorrect telemetry data renders inoperative the state estimator, a power flow monitoring tool operated by the Ohio-based Midwest Independent Transmission System Operator (MISO). An operator corrects the telemetry problem but forgets to restart the monitoring tool. • # 1:31 p.m. The Eastlake, Ohio generating plant shuts down. The plant is owned by FirstEnergy, an Akron, Ohio-based company that had experienced extensive recent maintenance problems. • # 2:02 p.m. The first of several 345 kV overhead transmission lines in northeast Ohio fails due to contact with a tree in Walton Hills, Ohio. • # 2:14 p.m. An alarm system fails at FirstEnergy's control room and is not repaired. • # 2:27 p.m. A second 345 kV line fails due to contact with a tree.

  6. Timeline • # 3:05 p.m. A 345 kV transmission line known as the Chamberlain-Harding line fails in Parma, south of Cleveland, due to a tree. • # 3:17 p.m. Voltage dips temporarily on the Ohio portion of the grid. Controllers take no action. • # 3:32 p.m. Power shifted by the first failure onto another 345 kV power line, the Hanna-Juniper interconnection, causes it to sag into a tree, bringing it offline as well. While MISO and FirstEnergy controllers concentrate on understanding the failures, they fail to inform system controllers in nearby states. • # 3:39 p.m. A FirstEnergy 138 kV line fails. • # 3:41 p.m. A circuit breaker connecting FirstEnergy's grid with that of American Electric Power is tripped as a 345 kV power line (Star-South Canton interconnection) and fifteen 138 kV lines fail in rapid succession in northern Ohio. Later analysis suggests that this could have been the last possible chance to save the grid if controllers had cut off power to Cleveland at this time. • # 3:46 p.m. A sixth 345 kV line, the Tidd-Canton Central line, trips offline. • # 4:06 p.m. A sustained power surge on some Ohio lines begins an uncontrollable cascade after another 345 kV line (Sammis-Star interconnection) fails. • # 4:09:02 p.m. Voltage sags deeply as Ohio draws 2 GW of power from Michigan, creating simultaneous undervoltage and overcurrent conditions as power attempts to flow in such a way as to rebalance the system's voltage. • # 4:10:34 p.m. Many transmission lines trip out, first in Michigan and then in Ohio, blocking the eastward flow of power around the south shore of Lake Erie. Suddenly bereft of demand, generating stations go offline, creating a huge power deficit. In seconds, power surges in from the east, overloading east-coast power plants whose generators go offline as a protective measure, and the blackout is on. • # 4:10:37 p.m. The eastern and western Michigan power grids disconnect from each other. Two 345 kV lines in Michigan trip. A line that runs from Grand Ledge to Ann Arbor known as the Oneida-Majestic interconnection trips. A short time later, a line running from Bay City south to Flint in Consumers Energy's system known as the Hampton-Thetford line also trips.

  7. Timeline • # 4:10:38 p.m. Cleveland separates from the Pennsylvania grid. • # 4:10:39 p.m. 3.7 GW power flows from the east along the north shore of Lake Erie, through Ontario to southern Michigan and northern Ohio, a flow more than ten times greater than the condition 30 seconds earlier, causing a voltage drop across the system. • # 4:10:40 p.m. Flow flips to 2 GW eastward from Michigan through Ontario (a net reversal of 5.7 GW of power), then reverses back westward again within a half second. • # 4:10:43 p.m. International connections between the United States and Canada begin failing. • # 4:10:45 p.m. Northwestern Ontario separates from the east when the Wawa-Marathon 230 kV line north of Lake Superior disconnects. The first Ontario power plants go offline in response to the unstable voltage and current demand on the system. • # 4:10:46 p.m. New York separates from the New England grid. • # 4:10:50 p.m. Ontario separates from the western New York grid. • # 4:11:57 p.m. The Keith-Waterman, Bunce Creek-Scott 230 kV lines and the St. Clair-Lambton #1 and #2 345 kV lines between Michigan and Ontario fail. • # 4:12:03 p.m. Windsor, Ontario and surrounding areas drop off the grid. • # 4:13 p.m. End of cascading failure. 256 power plants are off-line, 85% of which went offline after the grid separations occurred, most due to the action of automatic protective controls.

  8. 2003 Northeastern Blackout • 50 million people in the dark • Cost economy 1 billion dollars

  9. Getting the electricity from the plant to the light switch • Not a place for wireless technology-or is it?

  10. Wireless is not out of the question • Wireless transmission of electricity was actually pioneered by Nikola Tesla in late 19th century • Wireless power transmission is known as the Tesla effect • Based on inductive power transfer

  11. Tesla’s ideas

  12. Tesla envisioned a world wide electricity network • Tesla envisioned a world wide electricity network

  13. Inductive power transfer • An electric toothbrush recharges through three simple steps. • First, a current from the wall outlet is directed into the charger and into the base coil via an electric wire. • When the current flows through the base coil, the coil generates a magnetic field which in turn induces a current to flow to the coil in the toothbrush handle. • This charges the toothbrush battery.

  14. Inductive power transfer • But the objects have to be in contact, what about over a distance? • Problem is the magnetic field decreases over distance, so the magnetic field generated in the base has to be large, but this reduces efficiency • Using ideas of magnetic resonance, the distance can be greatly increased. • Over large distances and high powers, lasers, radio and microwaves can be used. • Many technology demonstrations of this have already occurred

  15. Heat Pumps • In a heat engine, heat is converted to mechanical energy by taking advantage of the fact that heat flows from hot to cold. The heat is taken from a source, some of it turned into mechanical energy and the rest sent to a heat sink, which is at a lower T than the source. • Could we reverse this process?

  16. Heat pumps • A compressor compresses a gas (Freon) to raise its Temperature and pressure. • It flows through a heat exchanger in which the gas is cooled by room temp air and it condenses. • The heat it gives up in condensing goes to heat the inside air around the heat exchanger. • The gas then passes through a valve to a region of lower pressure where it expands and becomes very cold. • It next passes through a heat exchanger exposed to outside air. The outside air warms the gas and it returns to the compressor and starts the cycle all over again. • Reverse the process for cooling

  17. Heat pumps

  18. Heat pumps • Effectiveness measured by the Coefficient of Performance • C.O.P. = Th/(Th-Tc) This comes from the Carnot Efficiency • As the outside air gets colder, Th-Tc gets larger to C.O.P decreases. This means heat pumps are less efficient in very cold weather and very cold climates. Usually this occurs when the outside T falls below 15 F.

  19. Peltier effect • Pelier was experimenting with electricity • Connected a bismuth and copper wire together and hooked them to a battery. • Found one side became hot and the other cold as the current flowed! • Basis for thermoelectric cooling/heating • Modern devices use semi-conductors (more efficient). • Not efficient enough for large scale heating or cooling

  20. Peltier effect

  21. Cogeneration • Power plants generate lots of waste heat • Modern coal fired plants convert 38% of the energy in the coal to electricity, the other 62% is waste! • Usually shed off into the environment (air, cooling pond, river, lake etc) • Can have environmental consequences • Can it be put to use?

  22. Cogeneration • Problem arises when the power plant is located far away from population centers- cannot effectively transport the heat over long distances • In principle, the waste heat could be used to heat a boiler and provide steam for pace heating and cooling. • Or it could be recycled to drive turbines to produce dditional electricity

  23. Types of cogeneration plants • Topping cycle plants - produce electricity from a steam turbine. The exhausted steam is then condensed, and the low temperature heat released from this condensation is utilized for heating. • Bottoming cycle plants- produce high temperature heat for industrial processes, then a waste heat recovery boiler feeds an electrical plant. Need a high initial source of heat-metal manufacturing plants.

  24. Examples • The New York City steam system - district heating system which carries steam from central power stations under the streets of Manhattan to heat, cool, or supply power to high rise buildings and businesses. • Another example is in use at the University of Colorado, Boulder - Total efficiency is 70% • Possibility of explosions due to pipe failures exists

  25. Example of Explosions • The July 18, 2007 New York City steam explosion sent a geyser of hot steam up from beneath a busy intersection, with a 40-story-high shower of mud and flying debris raining down on the crowded streets of Midtown Manhattan • It was caused by the failure of a Consolidated Edison 24-inch underground steam pipe installed in 1924

  26. Possibilities • Outside the U.S., energy recycling is more common. Denmark is probably the most active energy recycler, obtaining about 55% of its energy from cogeneration and waste heat recovery. • In the US about 8% of its electricity is produced via cogeneration

More Related