On February 16, 2010, a significant safety incident occurred at the Collider Accelerator Department, emphasizing the dire need for strict adherence to safety protocols. A KC-135 aircraft was pressurized incorrectly, leading to an explosive failure that blew the rear hatch over 70 yards. Additionally, a crane operation at a DOE site resulted in severe injuries due to improper manual battery charging. These incidents highlight the lack of procedures, pre-job briefings, and understanding of safety mechanisms among workers. Implementing strategies such as double verification and enhanced communication can prevent such incidents.

dalit
Télécharger la présentation

Enhancing Safety Protocols: Lessons from Incident at Collider Accelerator Department

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Reducing Errors Collider-Accelerator Department 2-16-2010 Take 5 for Safety

  2. No Instructions Or Checklists • A KC-135 Aircraft was being pressurized at ground level • The outflow valves used to regulate the pressure of the aircraft were capped off during a 5 year overhaul and never opened back up • The technician who, "had always done it that way," was using a pressure gauge with no maximum markings, and no procedure • The rear hatch was blown over 70 yards away, behind a blast fence

  3. No Instructions Or Pre-job Briefing • A crane was staged for use on a DOE site and a manual charger was used to charge the batteries when one of the batteries failed explosively, spreading battery acid 25 feet and injuring three people • The worker performing manual battery charging did not understand the potential problems • The charger's output was set at 24 volts, delivering a constant charging current of approximately 10 amps until it is manually shut off • If not shutoff when the battery is fully charged, a manual charger can overheat and destroy a battery • In contrast, an automatic charger or "Smart" charger will adjust its charge rate dependent upon electrical resistance, and will gradually step down the charging current as the battery charges

  4. Error Reduction Strategies • Pre-job briefing • Questioning attitude • Double verification • Independent verification • Conservative decision making • Flagging (color coding, labeling, procedures, checklists) • Communicating the operating experience to workers • Supervisor / manager monitoring