1 / 18

Martin Elvis Smithsonian Astrophysical Observatory

Welcome to the 4 th Chandra – CIAO Workshop 20 – 22 May 2002. Martin Elvis Smithsonian Astrophysical Observatory. Chandra X-ray Observatory Overview. Martin Elvis Smithsonian Astrophysical Observatory CIAO Workshop 20 May 2001. NASA Great Observatories. CHANDRA. Focusing X-rays.

dima
Télécharger la présentation

Martin Elvis Smithsonian Astrophysical Observatory

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Welcome to the 4th Chandra – CIAO Workshop 20 – 22 May 2002 Martin Elvis Smithsonian Astrophysical Observatory

  2. Chandra X-ray Observatory Overview Martin Elvis Smithsonian Astrophysical Observatory CIAO Workshop 20 May 2001

  3. NASA Great Observatories CHANDRA

  4. Focusing X-rays

  5. Chandra Mission Summary • Launch: July 23, 1999 • STS-93/ Inertial Upper Stage / Integral Propulsion System • 10,000 km x 140,000 km, 28.4o Inclined Orbit • Design Lifetime > 5 Years (in NASA plan for 10 year life) • 10-m Focal Length Wolter -1 Mirror: 4 nested Mirror Pairs • Energy Range: 0.1-10 keV • ¼ arcsecond resolution. Sub-0.5arcsec in practice • 2 Imaging Focal Plane Science Instruments • ACIS (Advanced CCD Imaging Spectrometer) • HRC (High Resolution Camera) • 2 Objective Transmission Gratings for Dispersive Spectroscopy • LETG(Low-Energy Transmission Grating) • HETG(High-Energy Transmission Grating)

  6. Mission and Observatory Description

  7. High Resolution Mirror Assembly • 4 pairs of concentric thin-walled zerodur, grazing incidence Wolter Type-I mirrors ->large area. ->800cm2 E<2keV Antennae galaxies • figured to 0.5” FWHM -> sensitivity, -> megapixel images • Focal length 10 m. -> response to 10keV Many independent pixels High sensitivity • polished to 3A -> low scattering high dynamic range Iridium edge PSR nebula PKS1127-145 95% High energy sources 100:1 AGN/jet contrast 1.6”

  8. Aspect Camera and Fiducial Transfer System Aspect Camera 4.25inch dia.15”pixels <0.25” r ms (typical)

  9. Chandra Science Instruments Z+ ACIS-I • Advanced CCD Imaging Spectrometer (ACIS) • CCD array with 16’x16’ field of view (ACIS-I) • grating readout array (ACIS-S) • High Resolution Camera (HRC) • microchannel plate imager with 31’x31’ field of view (HRC-I) • low energy grating readout array (HRC-S) • High time resolution • High Energy Transmission Grating Spectrometer (HETG) • transmission grating pairs for medium and high energy • Low Energy Transmission Grating Spectrometer (LETG) • transmission grating for low energy BI BI Y+ ACIS-S HRC-I HRC-S

  10. Advanced CCD Imaging Spectrometer (ACIS) • Ten 1024x1024 pixel CCDs (any 6 simultaneously) • Intrinsic energy resolution ~100eV -> imaging spectroscopy • ACIS-I: 2x2 array for imaging (16x16 arcmin) • ACIS-S: 1x6 array for imaging (8x8arcmin) or spectroscopy • 2 `back illuminated’ (BI) chips: good low E QE, higher throughput

  11. ACIS Issues CTI • Front Iluminated (FI) chips suffered proton damage just after launch. -> charge transfer inefficiency (CTI) -> much degraded energy resolution • CTI correction (Townsley, PSU) restores linearity, most dE/E Pileup • 3.2 s full frame readout time -> for sources >0.1ct/s suffer “pileup” I.e. 2 photons in same pixel/frame -> loss of energy information, and -> loss of PSF peak • Pileup correction (J.Davis, MIT) available in CIAO, Sherpa Low Energy Calibration • Non-linear gain • Changing QE • See H. Donnely talk

  12. Chandra Grating Spectrometers m=2 d Incoming Radiation m=1  m=0 m=-1 m = d sin m=-2

  13. Grating Spectrometers:HETG • HETG: High Energy Transmission Gratings • Designed for use with ACIS-S providing E/delta(E) to 1000 between 0.4 and 10.0 keV • Two sets of gratings • Medium Energy Gratings (MEG) use outer 2 mirrors • High Energy Gratings (HEG) use inner 2 mirrors • Mounted at different angles to form an “X” dispersed pattern Capella HETG spectrum

  14. Grating Spectrometers: LETG • LETG High Energy Transmission Gratings • Provides highest resolving power at low energies • Designed for use with HRC-S with 0.07 – 7.29 keV • E/delta(E) > 1000 for 0.07 < E < 0.15 keV • E/delta(E) < 1000 for E > 0.15 keV

  15. Chandra Operations • Mission science plan converted to command loads and uplinked to Chandra • X-ray events collected and stored on Solid-State Recorders (SSR) • Ground contact established every ~8 hours through Deep Space Network • SSR data downlinked • new command load uplinked (up to 72 hours of stored commands) • Data transferred to OCC through JPL for science processing sssssssssssssssssssssss CXO CXC OCC

  16. 6. Chandra X-ray Center Architecture uplink downlink

  17. Chandra Observing Cycle • High (66%) observing efficiency • TOOs, solar flares ->big hit on mission planning team • Annual Proposal Cycle: • Next Deadline: 15 March 2003 (anticipated) • + Archive, Theory grants • Funding expected to 2009

  18. enjoy the workshop!