1 / 80

Network Manager DMS Release 3 New Features Martin Bass

Network Manager DMS Release 3 New Features Martin Bass. ABB Annual Users’ Group Meeting August 27 – 31, 2006. Release 3 (2006) New Features. New features for Network Manager DMS Release 3 Consult release notes for details Some features may require additional license fee

duncan
Télécharger la présentation

Network Manager DMS Release 3 New Features Martin Bass

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Network Manager DMS Release 3 New FeaturesMartin Bass ABB Annual Users’ Group Meeting August 27 – 31, 2006

  2. Release 3 (2006) New Features • New features for Network Manager DMS Release 3 • Consult release notes for details • Some features may require additional license fee • Release numbering has changed back to a numbered version, to be consistent with Network Manager suite of products

  3. Release 3 New Features • Double click brings up outage detail in OMI • Right mouse in OMI status dialog brings up menu • Drag outage and drop onto crew to assign • netCADOPS call entry will allow non-customer calls to be tied to street intersection • Crew Status Dialog changes • Security check changes • Add Cogenerator • Advanced Switching Order enhancements

  4. Release 3 New Features, 2 • ICCP Interface to SCADA • Color by Planned • Split Mode Architecture • Show Selected Conductors • Independent symbol scaling • Admin database changes • Bus bar changes • Data maintenance • Mobile Data Integration

  5. Right Mouse Menu in OMI Status Dialog • Right click on a selected outage • Actions menu will appear

  6. Drag Outage and Drop Onto Crew to Assign • Left click outage on outage status dialog • Drag outage and drop onto crew status dialog • ‘Fast Assign’ is done automatically

  7. Non-customer Call Entry Street Intersection • Requires street intersection table for each transformer • Table holds closest transformer for each intersection • User enters two streets • Transformer automatically associated with value • If multiple matches, first transformer will be used • Dispatcher may have to correct, if needed.

  8. New Entry Area in Non-Customer Call

  9. Intersection Popup • User Presses Find or lookup • List of matching intersections pop up • User Selects an intersection

  10. Street Intersection • Intersection and City automatically populated • Transformer ID added automatically behind the scenes

  11. Non-customer Call Shows in OMI • Non-customer call is automatically tied to transformer • Call is locatable

  12. Cause and Equipment for Non-Customer Calls

  13. Crew Status Dialog Changes • Show feeder and substation on crew status dialog • Toggle to filter logged off crews

  14. Crew Status Dialog Changes • Ability to change work operation center in OMI • Set current Operation Center from Crew Status dialog • Toggle to filter crew status dialog by Operation Center • Operation center filtered by Ormap login

  15. Do Not Tie/Parallel Tag • Special connectivity tag • Can be placed on any tie switch • Prevents a parallel from being made • Allows switch to be operated if de-energizing or energizing

  16. Security Checking – Do not Tie • Do not tie tag

  17. Security Checking – Phase Difference • Check for phase angle difference • Nominal phase angle trace from source(s) • Does not use UBLF • Accounts for 30 deg phase shifts in wye-delta, delta-wye transformers • Warns operator when making parallel if circuits do not phase because of transformer connections • Warning issued if over limit

  18. Automatic Throwover Warnings • Warning when switch in an ATO will operate due to energization change

  19. Add Temporary Generator • Similar to add generator • Prompts user for temporary generator information before adding

  20. Safety Document Includes Clearance Tracking • Top window shows summary of tag steps in switching plan • Middle window shows clearance status for each crew • Bottom window shows details of clearance selected in middle window

  21. Advanced Switch Order Templates • Templates can now be saved under area of responsibility • User selects a single AOR from a tree

  22. Advanced Switch Order Templates • Warning issued if steps not in selected sub area

  23. ICCP SCADA Interface • ICCP – Inter Control Center Protocol (TASE.2) • Industry standard for EMS to EMS communications • Set of conformance blocks define functions supported • Release 3 implementation supports • Incoming status values • Incoming analog values

  24. Supported ICCP Conformance Blocks • Block 1 (periodic data transfer) • Data can be grouped to be transferred at different intervals • Block 2 (exception reporting) • Used for status changes • Only changes are sent • Includes periodic sending of entire data set • Block 5 (Device control). Future release. Will also support two-way tagging.

  25. Unsupported ICCP Conformance Blocks • The following blocks will not be supported • Block 3 (Block data transfer) • Block 4 (Information messages) • Block 6 (Program Control) • Block 7 (Event reporting) • Block 8 (Additional User Objects) • Block 9 (Time Series Data)

  26. Typical Configuration Diagram ICCP Server (Windows) SCADA System ICCP Server NM DMS Application Server SCADA System

  27. Bilateral Tables • ICCP maps point names to Network Manager DMS names via Bilateral Tables • SCADA system has table to map point name to ID that is sent over the wire • Network Manager DMS has table to map ID sent over the wire to Device ID • ID sent over the wire is determined by mutual agreement

  28. ICCP Implementation Details • Separate Windows server runs SISCO MMS-Ease Software • Communicates to Network Manager DMS Server via Smart Sockets

  29. Color by Planned • New coloring option: • Color by Planned • Separate colors for: • In Service • Planned addition • Planned deletion

  30. Color By Conductor Capacity • Color by conductor rating • Colors are user configurable

  31. Color By Conductor Capacity Margin • Color by conductor rating less results of load flow (requires load flow option) • Colors are user configurable

  32. Show Selected Conductors • Tool to highlight conductors of a given type

  33. Select Conductors, press OK

  34. Selected Conductors are Highlighted

  35. Independent Symbol Scaling • User can increase or decrease symbols according to category • Category defined in symbol_category table

  36. Select Symbol to resize from pulldown

  37. Press Increase/decrease Size Button

  38. Press ‘G’ Button to Reset Symbol Size

  39. Multiple Administrator Databases • A registry setting allows user to specify admin database to use when logging in • Up to 32 admin databases can be defined • Screen shot shows 3 admin databases

  40. Multiple Administrator Databases • User is presented with menu of admin databases to select when logging in

  41. Bus Bar Line Style • New busbar line style defined • Defined by bus_bar attribute in line_type table • Old line style table no longer supported • Bus_bar attribute in line table no longer supported • Bus bar nodes being phased out

  42. Data Maintenance • Merge data maintenance to common code base • Data Maintenance login authority • Add and delete equipment with on-line incremental update • Edit and specify equipment properties with on-line incremental update • Includes ATOs

  43. DM Login Authority • User’s login account must be given DM authority • User chooses data maintenance GUI at login • DM GUI is fully functional but not intended for operations

  44. DM Login Authority in Database • Add record to ADM_USER_CLASSES table • Record contains the following information: • USR_ID = login user id • CLS_CODE = ‘DM’

  45. Logging into Data Maintenance • Check the Data Maintenance box • Select the Operator from the pull down list • Note: Pull down list of operations only shows operators with Data Maintenance authority

  46. Data Maintenance GUI • Ormap title bar indicates that operator is in data maintenance

  47. DM Login Authority in Database • Select Toolbars | Components to get the component editing toolbar • Component Editing toolbar appears as shown below

  48. DM Login Authority in Database • Select Toolbars | DM Specials to get the data maintenance specials editing toolbar • DM Specials Editing toolbar appears as shown below

  49. Adding a Line • Select the Line icon on the DM component toolbar • Hold the cursor down at the starting position of the line • Drag it to the end node position and release • New line is created

  50. Data Maintenance Operator Warning • Operator is warned when a data maintenance operation is performed • Operator can choose to ignore warnings • Remember that all data maintenance operations go to all operational consoles immediately

More Related